These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 35420928)

  • 1. Are Pediatric Manual Resuscitators Only Fit for Pediatric Use? A Comparison of Ventilation Volumes in a Moving Ambulance.
    Sun G; Wojcik S; Noce J; Cochran-Caggiano N; DeSantis T; Friedman S; Cooney DR; Knutsen C
    Prehosp Emerg Care; 2023; 27(4):501-505. PubMed ID: 35420928
    [No Abstract]   [Full Text] [Related]  

  • 2. A strategy to optimise the performance of the mouth-to-bag resuscitator using small tidal volumes: effects on lung and gastric ventilation in a bench model of an unprotected airway.
    Zecha-Stallinger A; Wenzel V; Wagner-Berger HG; von Goedecke A; Lindner KH; Hörmann C
    Resuscitation; 2004 Apr; 61(1):69-74. PubMed ID: 15081184
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessment of Ventilation Using Adult and Pediatric Manual Resuscitators in a Simulated Adult Patient.
    Justice JM; Slutsky AS; Stanford N; Isennock C; Siddiqui S; Zamir H; Walker JR; Brady MF
    Respir Care; 2024 Jul; 69(8):924-930. PubMed ID: 38688544
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Can EMS Providers Provide Appropriate Tidal Volumes in a Simulated Adult-sized Patient with a Pediatric-sized Bag-Valve-Mask?
    Siegler J; Kroll M; Wojcik S; Moy HP
    Prehosp Emerg Care; 2017; 21(1):74-78. PubMed ID: 27690714
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Peak airway pressure is lower during pressure-controlled than during manual facemask ventilation for induction of anesthesia in pediatric patients-a randomized, clinical crossover trial.
    Goebel U; Schumann S; Wirth S
    J Anesth; 2019 Feb; 33(1):33-39. PubMed ID: 30421240
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimizing bag-valve-mask ventilation with a new mouth-to-bag resuscitator.
    Wagner-Berger HG; Wenzel V; Stallinger A; Voelckel WG; Rheinberger K; Augenstein S; Herff H; Idris AH; Dörges V; Lindner KH; Hörmann C
    Resuscitation; 2003 Feb; 56(2):191-8. PubMed ID: 12589994
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Can you deliver accurate tidal volume by manual resuscitator?
    Lee HM; Cho KH; Choi YH; Yoon SY; Choi YH
    Emerg Med J; 2008 Oct; 25(10):632-4. PubMed ID: 18843057
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of Simulated Ventilation Techniques With the Upright and Conventional Self-Inflating Neonatal Resuscitators.
    Narayanan I; Mendhi M; Bansil P; Coffey PS
    Respir Care; 2017 Nov; 62(11):1428-1436. PubMed ID: 28830928
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Manual resuscitators and spontaneous ventilation--an evaluation.
    Mills PJ; Baptiste J; Preston J; Barnas GM
    Crit Care Med; 1991 Nov; 19(11):1425-31. PubMed ID: 1935164
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Developing a strategy to improve ventilation in an unprotected airway with a modified mouth-to-bag resuscitator in apneic patients.
    von Goedecke A; Keller C; Wagner-Berger HG; Voelckel WG; Hörmann C; Zecha-Stallinger A; Wenzel V
    Anesth Analg; 2004 Nov; 99(5):1516-1520. PubMed ID: 15502057
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Tidal volumes and pressures delivered by the NeoPuff T-piece resuscitator during resuscitation of term newborns.
    Bjorland PA; Ersdal HL; Haynes J; Ushakova A; Øymar K; Rettedal SI
    Resuscitation; 2022 Jan; 170():222-229. PubMed ID: 34915085
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Artificial ventilation during transport: A randomized crossover study of manual resuscitators with comparison to mechanical ventilators in a simulation model.
    Lucy MJ; Gamble JJ; Peeling A; Lam JTH; Balbuena L
    Paediatr Anaesth; 2018 Sep; 28(9):788-794. PubMed ID: 30175433
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of decreasing inspiratory flow rate during simulated basic life support ventilation of a cardiac arrest patient on lung and stomach tidal volumes.
    Stallinger A; Wenzel V; Wagner-Berger H; Schäfer A; Voelckel WG; Augenstein S; Dörges V; Idris AH; Lindner KH; Hörmann C
    Resuscitation; 2002 Aug; 54(2):167-73. PubMed ID: 12161296
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Emergency Medical Services Responder Manual Ventilation Performance.
    Ni SA; Carpenter RS; Walker JR; Holley J; Brady MF
    Prehosp Emerg Care; 2023; 27(4):496-500. PubMed ID: 35442149
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Randomised comparison of two neonatal resuscitation bags in manikin ventilation.
    Thallinger M; Ersdal HL; Ombay C; Eilevstjønn J; Størdal K
    Arch Dis Child Fetal Neonatal Ed; 2016 Jul; 101(4):F299-303. PubMed ID: 26437670
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Endotracheal aspiration: respirator vs. manual resuscitation as method for hyperoxygenation and hyperinflation].
    Herce A; Lerga C; Martínez A; Zapata MA; Asiain MC
    Enferm Intensiva; 1999; 10(3):99-109. PubMed ID: 10732589
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Monitoring tidal volumes when using the Ventrain® emergency ventilator].
    Schmidt AR; Ruetzler K; Haas T; Schmitz A; Weiss M
    Anaesthesist; 2016 Jul; 65(7):514-20. PubMed ID: 27245923
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impact of a pressure-responsive flow-limiting valve on bag-valve-mask ventilation in an airway model.
    Busko JM; Blackwell TH
    CJEM; 2006 May; 8(3):158-63. PubMed ID: 17320009
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of three methods of bag valve mask ventilation.
    Wheatley S; Thomas AN; Taylor RJ; Brown T
    Resuscitation; 1997 Jan; 33(3):207-10. PubMed ID: 9044491
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of different airway management strategies to ventilate apneic, nonpreoxygenated patients.
    Dörges V; Wenzel V; Knacke P; Gerlach K
    Crit Care Med; 2003 Mar; 31(3):800-4. PubMed ID: 12626987
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.