These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
154 related articles for article (PubMed ID: 35422146)
1. Comparison of Icare HOME and non-contact tonometer in intraocular pressure measurement in the early stage after ICL V4c implantation. Ye Y; Yang F; Ding L; Xia F; Niu L; Wang X; Zhao J; Zhou X Eur J Ophthalmol; 2022 Nov; 32(6):3303-3311. PubMed ID: 35422146 [TBL] [Abstract][Full Text] [Related]
2. Agreement among Goldmann applanation tonometer, iCare, and Icare PRO rebound tonometers; non-contact tonometer; and Tonopen XL in healthy elderly subjects. Kato Y; Nakakura S; Matsuo N; Yoshitomi K; Handa M; Tabuchi H; Kiuchi Y Int Ophthalmol; 2018 Apr; 38(2):687-696. PubMed ID: 28393323 [TBL] [Abstract][Full Text] [Related]
3. Comparison of Three Methods of Tonometry in Patients with Inactive Thyroid-Associated Orbitopathy. Karhanová M; Kalitová J; Malušková M; Schovánek J; Zapletalová J; Mlčák P; Marešová K Cesk Slov Oftalmol; 2023; 79(6):318-323. PubMed ID: 38086704 [TBL] [Abstract][Full Text] [Related]
4. Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group. Chen M; Zhang L; Xu J; Chen X; Gu Y; Ren Y; Wang K BMC Ophthalmol; 2019 Nov; 19(1):225. PubMed ID: 31726999 [TBL] [Abstract][Full Text] [Related]
5. [Reliability and reproducibility of introcular pressure (IOP) measurement with the Icare Valero B; Fénolland JR; Rosenberg R; Sendon D; Mesnard C; Sigaux M; Giraud JM; Renard JP J Fr Ophtalmol; 2017 Dec; 40(10):865-875. PubMed ID: 29174296 [TBL] [Abstract][Full Text] [Related]
6. Comparative measurement of intraocular pressure by Icare tonometry and Airpuff tonometry in healthy subjects and patients wearing therapeutic soft contact lenses. Anton A; Neuburger M; Böhringer D; Jordan JF Graefes Arch Clin Exp Ophthalmol; 2013 Jul; 251(7):1791-5. PubMed ID: 23532453 [TBL] [Abstract][Full Text] [Related]
7. Comparison of the new rebound tonometer with Goldmann applanation tonometer in a clinical setting. Kim KN; Jeoung JW; Park KH; Yang MK; Kim DM Acta Ophthalmol; 2013 Aug; 91(5):e392-6. PubMed ID: 23521889 [TBL] [Abstract][Full Text] [Related]
15. Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer over a wide IOP range. Munkwitz S; Elkarmouty A; Hoffmann EM; Pfeiffer N; Thieme H Graefes Arch Clin Exp Ophthalmol; 2008 Jun; 246(6):875-9. PubMed ID: 18196259 [TBL] [Abstract][Full Text] [Related]
16. A comparison of goldmann applanation tonometry and rebound tonometry measurements among patients attending a glaucoma clinic in Southwest Nigeria. Ashano O; Oderinlo O; Ogunro A; Ashano E Niger J Clin Pract; 2022 Sep; 25(9):1542-1547. PubMed ID: 36149217 [TBL] [Abstract][Full Text] [Related]
17. Inter-optometrist variability of IOP measurement for modern tonometers and their agreement with Goldmann Applanation Tonometry. Campbell P; Edgar DF; Shah R Clin Exp Optom; 2021 Jul; 104(5):602-610. PubMed ID: 33689641 [No Abstract] [Full Text] [Related]
18. Performance of home-based self-tonometry (iCare HOME (TA022)) for measuring intraocular pressure among healthy and glaucoma patients. Nayak A; Ramesh SV; Kuzhuppilly NIR; Pai VH; Chaitanya A F1000Res; 2023; 12():128. PubMed ID: 38894819 [No Abstract] [Full Text] [Related]
19. Evaluation of a New Rebound Self-tonometer, Icare HOME: Comparison With Goldmann Applanation Tonometer. Takagi D; Sawada A; Yamamoto T J Glaucoma; 2017 Jul; 26(7):613-618. PubMed ID: 28369004 [TBL] [Abstract][Full Text] [Related]
20. The Utility of iCare HOME Tonometry for Detection of Therapy-Related Intraocular Pressure Changes in Glaucoma and Ocular Hypertension. Scott AT; Kanaster K; Kaizer AM; Young CC; Pantcheva MB; Ertel MK; Kahook MY; Seibold LK Ophthalmol Glaucoma; 2022; 5(1):85-93. PubMed ID: 34082179 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]