188 related articles for article (PubMed ID: 35434864)
21. Linear projection-based chemical exchange saturation transfer parameter estimation.
Glang F; Fabian MS; German A; Khakzar KM; Mennecke A; Liebert A; Herz K; Liebig P; Kasper BS; Schmidt M; Zuazua E; Nagel AM; Laun FB; Dörfler A; Scheffler K; Zaiss M
NMR Biomed; 2023 Jun; 36(6):e4697. PubMed ID: 35067998
[TBL] [Abstract][Full Text] [Related]
22. Free-base porphyrins as CEST MRI contrast agents with highly upfield shifted labile protons.
Zhang X; Yuan Y; Li S; Zeng Q; Guo Q; Liu N; Yang M; Yang Y; Liu M; McMahon MT; Zhou X
Magn Reson Med; 2019 Aug; 82(2):577-585. PubMed ID: 30968442
[TBL] [Abstract][Full Text] [Related]
23. Motion correction of chemical exchange saturation transfer MRI series using robust principal component analysis (RPCA) and PCA.
Bie C; Liang Y; Zhang L; Zhao Y; Chen Y; Zhang X; He X; Song X
Quant Imaging Med Surg; 2019 Oct; 9(10):1697-1713. PubMed ID: 31728313
[TBL] [Abstract][Full Text] [Related]
24. Detection of tissue pH with quantitative chemical exchange saturation transfer magnetic resonance imaging.
Igarashi T; Kim H; Sun PZ
NMR Biomed; 2023 Jun; 36(6):e4711. PubMed ID: 35141979
[TBL] [Abstract][Full Text] [Related]
25. Nuts and bolts of chemical exchange saturation transfer MRI.
Liu G; Song X; Chan KW; McMahon MT
NMR Biomed; 2013 Jul; 26(7):810-28. PubMed ID: 23303716
[TBL] [Abstract][Full Text] [Related]
26. Induced saturation transfer recovery steady states (iSTRESS) for proton exchange rate mapping with CEST MRI, a preliminary study.
Shaghaghi M; Damen FC; Li W; Tai LM; Cai K
Magn Reson Imaging; 2024 Jun; 109():264-270. PubMed ID: 38522624
[TBL] [Abstract][Full Text] [Related]
27. Validation of the presence of fast exchanging amine CEST effect at low saturation powers and its influence on the quantification of APT.
Sun C; Zhao Y; Zu Z
Magn Reson Med; 2023 Oct; 90(4):1502-1517. PubMed ID: 37317709
[TBL] [Abstract][Full Text] [Related]
28. Comparison of model-free Lorentzian and spinlock model-based fittings in quantitative CEST imaging of acute stroke.
Wu L; Lu D; Sun PZ
Magn Reson Med; 2023 Nov; 90(5):1958-1968. PubMed ID: 37335834
[TBL] [Abstract][Full Text] [Related]
29. In vivo lymph node CEST-Dixon MRI in breast cancer patients with metastatic lymph node involvement.
Donahue MJ; Donahue PMC; Jones RS; Garza M; Lee C; Patel NJ; Cooper A; De Vis JB; Meszoely I; Crescenzi R
Magn Reson Med; 2024 Feb; 91(2):670-680. PubMed ID: 37684712
[TBL] [Abstract][Full Text] [Related]
30. Guanidinium and amide CEST mapping of human brain by high spectral resolution CEST at 3 T.
Wang K; Park S; Kamson DO; Li Y; Liu G; Xu J
Magn Reson Med; 2023 Jan; 89(1):177-191. PubMed ID: 36063502
[TBL] [Abstract][Full Text] [Related]
31. Amine-weighted chemical exchange saturation transfer magnetic resonance imaging in brain tumors.
Cho NS; Hagiwara A; Yao J; Nathanson DA; Prins RM; Wang C; Raymond C; Desousa BR; Divakaruni A; Morrow DH; Nghiemphu PL; Lai A; Liau LM; Everson RG; Salamon N; Pope WB; Cloughesy TF; Ellingson BM
NMR Biomed; 2023 Jun; 36(6):e4785. PubMed ID: 35704275
[TBL] [Abstract][Full Text] [Related]
32. Protein aggregation linked to Alzheimer's disease revealed by saturation transfer MRI.
Chen L; Wei Z; Chan KWY; Cai S; Liu G; Lu H; Wong PC; van Zijl PCM; Li T; Xu J
Neuroimage; 2019 Mar; 188():380-390. PubMed ID: 30553917
[TBL] [Abstract][Full Text] [Related]
33. A Brief History and Future Prospects of CEST MRI in Clinical Non-Brain Tumor Imaging.
Gao T; Zou C; Li Y; Jiang Z; Tang X; Song X
Int J Mol Sci; 2021 Oct; 22(21):. PubMed ID: 34768990
[TBL] [Abstract][Full Text] [Related]
34. Investigating hydroxyl chemical exchange using a variable saturation power chemical exchange saturation transfer (vCEST) method at 3 T.
Clark DJ; Smith AK; Dortch RD; Knopp MV; Smith SA
Magn Reson Med; 2016 Sep; 76(3):826-37. PubMed ID: 26414937
[TBL] [Abstract][Full Text] [Related]
35. Analytical solution of the Bloch-McConnell equations for steady-state CEST Z-spectra.
Shaghaghi M; Cai K
Magn Reson Imaging; 2024 Jun; 109():74-82. PubMed ID: 38430977
[TBL] [Abstract][Full Text] [Related]
36. Multiparametric exchange protons using Z-spectrum analysis proton (ZAP) and CEST on phantoms and human abdomen.
Malis V; Miyazaki M
Magn Reson Med; 2024 May; ():. PubMed ID: 38703021
[TBL] [Abstract][Full Text] [Related]
37. Dual contrast CEST MRI for pH-weighted imaging in stroke.
Chung J; Sun D; Hitchens TK; Modo M; Bandos A; Mettenburg J; Wang P; Jin T
Magn Reson Med; 2024 Jan; 91(1):357-367. PubMed ID: 37798945
[TBL] [Abstract][Full Text] [Related]
38. CEST and nuclear Overhauser enhancement imaging with deep learning-extrapolated semisolid magnetization transfer reference: Scan-rescan reproducibility and reliability studies.
Heo HY; Singh M; Yedavalli V; Jiang S; Zhou J
Magn Reson Med; 2024 Mar; 91(3):1002-1015. PubMed ID: 38009996
[TBL] [Abstract][Full Text] [Related]
39. Chemical Exchange Saturation Transfer MRI: What Neuro-Oncology Clinicians Need To Know.
Jabehdar Maralani P; Chan RW; Lam WW; Oakden W; Oglesby R; Lau A; Mehrabian H; Heyn C; Chan AKM; Soliman H; Sahgal A; Stanisz GJ
Technol Cancer Res Treat; 2023; 22():15330338231208613. PubMed ID: 37872686
[TBL] [Abstract][Full Text] [Related]
40. d-glucose weighted chemical exchange saturation transfer (glucoCEST)-based dynamic glucose enhanced (DGE) MRI at 3T: early experience in healthy volunteers and brain tumor patients.
Xu X; Sehgal AA; Yadav NN; Laterra J; Blair L; Blakeley J; Seidemo A; Coughlin JM; Pomper MG; Knutsson L; van Zijl PCM
Magn Reson Med; 2020 Jul; 84(1):247-262. PubMed ID: 31872916
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]