BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 35441070)

  • 1. Delayed Hypersensitivity Reaction to Titanium-coated Polypropylene Mesh in Breast Reconstruction.
    Jouve E; Giordano-Labadie F; Selmes G; Soule-Tholy M; Navarro AS; Gangloff D; Meresse T; Duprez-Paumier R; Tournier E; Vaysse C
    Plast Reconstr Surg Glob Open; 2022 Apr; 10(4):e4232. PubMed ID: 35441070
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Management of Implant Exposure in One-Stage Breast Reconstruction Using Titanium-Coated Polypropylene Mesh: Sub-Mammary Intercostal Perforator Flap.
    De Riggi MA; Rocco N; Gherardini G; Esposito E; D'Aiuto M
    Aesthetic Plast Surg; 2016 Dec; 40(6):896-900. PubMed ID: 27766402
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implant-based breast reconstruction using a titanium-coated polypropylene mesh (TiLOOP Bra): a multicenter study of 231 cases.
    Dieterich M; Paepke S; Zwiefel K; Dieterich H; Blohmer J; Faridi A; Klein E; Gerber B; Nestle-Kraemling C
    Plast Reconstr Surg; 2013 Jul; 132(1):8e-19e. PubMed ID: 23806958
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A short follow-up of prosthesis-based breast reconstruction using TiLOOP
    Chen WX; Cheng L; Xu LY; Zhu YL
    Niger J Clin Pract; 2019 Aug; 22(8):1115-1119. PubMed ID: 31417055
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Skin-Areola, Nipple Sparing, and Subcutaneous Mastectomy and Immediate Implant-Based Breast Reconstruction Using a Titanium-Coated Polypropylene Mesh.
    Özel L; Kara VM; Sunamak O; Karagüllü H; Sağıroğlu J; İlhan O; Aker F
    J Breast Health; 2015 Jul; 11(3):141-143. PubMed ID: 28331710
    [TBL] [Abstract][Full Text] [Related]  

  • 6. TiLoop® Bra mesh used for immediate breast reconstruction: comparison of retropectoral and subcutaneous implant placement in a prospective single-institution series.
    Casella D; Bernini M; Bencini L; Roselli J; Lacaria MT; Martellucci J; Banfi R; Calabrese C; Orzalesi L
    Eur J Plast Surg; 2014; 37(11):599-604. PubMed ID: 25339795
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Can titanium mesh influence local recurrence management after implant-based breast reconstruction?
    Riggio E; Chifu C; Martelli G; Ferraris C
    Springerplus; 2015; 4():482. PubMed ID: 26361583
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Titanium-coated polypropylene mesh as innovative bioactive material in conservatives mastectomies and pre-pectoral breast reconstruction.
    Gentile P; Bernini M; Orzalesi L; Sordi S; Meattini I; Lessi F; Kothari A; Calabrese C
    Bioact Mater; 2021 Dec; 6(12):4640-4653. PubMed ID: 34095622
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A short-term follow-up of implant based breast reconstruction using a titanium-coated polypropylene mesh (TiLoop(®) Bra).
    Dieterich M; Reimer T; Dieterich H; Stubert J; Gerber B
    Eur J Surg Oncol; 2012 Dec; 38(12):1225-30. PubMed ID: 22981749
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pregnancy following Unilateral Immediate Breast Reconstruction with Titanized Polypropylene Mesh (TiLOOP(R) Bra) without Compromising the Result.
    Nolte E; Klein E; Paepke S
    Plast Reconstr Surg Glob Open; 2018 Sep; 6(9):e1919. PubMed ID: 30349788
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of demographic and perioperative risk factors on complication rates in skin-sparing/nipple-sparing mastectomy with implant-based reconstruction using titanized polypropylene mesh (TiLOOP® Bra).
    Michno V; Malter W; Paepke S; Thill M; Kelling K; Meiré A; Tofall S; Nolte E; Christ H; Eichler C
    Surg Oncol; 2022 Mar; 40():101675. PubMed ID: 34871867
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of Prepectoral Implant Placement and Complete Coverage with TiLoop Bra Mesh for Breast Reconstruction: A Prospective Study on Long-Term and Patient-Reported BREAST-Q Outcomes.
    Casella D; Di Taranto G; Marcasciano M; Sordi S; Kothari A; Kovacs T; Lo Torto F; Cigna E; Calabrese C; Ribuffo D
    Plast Reconstr Surg; 2019 Jan; 143(1):1e-9e. PubMed ID: 30303929
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Nipple-sparing bilateral prophylactic mastectomy and immediate reconstruction with TiLoop
    Casella D; Di Taranto G; Marcasciano M; Sordi S; Kothari A; Kovacs T; Lo Torto F; Cigna E; Ribuffo D; Calabrese C
    Breast; 2018 Jun; 39():8-13. PubMed ID: 29455110
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Postoperative Complications in Breast Reconstruction With Porcine Acellular Dermis and Polypropylene Meshes in Subpectoral Implant Placement.
    Schüler K; Paepke S; Kohlmann T; Alwafai Z; Nawroth F; Zygmunt M; Ohlinger R
    In Vivo; 2021; 35(5):2739-2746. PubMed ID: 34410963
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Using a titanium-coated polypropylene mesh (TiLOOP(®) Bra) for implant-based breast reconstruction: case report and histological analysis.
    Dieterich M; Dieterich H; Timme S; Reimer T; Gerber B; Stubert J
    Arch Gynecol Obstet; 2012 Jul; 286(1):273-6. PubMed ID: 22366804
    [No Abstract]   [Full Text] [Related]  

  • 16. Patient-Report Satisfaction and Health-Related Quality of Life in TiLOOP® Bra-Assisted or Implant-Based Breast Reconstruction Alone.
    Dieterich M; Angres J; Stachs A; Glass A; Reimer T; Gerber B; Stubert J
    Aesthetic Plast Surg; 2015 Aug; 39(4):523-33. PubMed ID: 26085227
    [TBL] [Abstract][Full Text] [Related]  

  • 17. What do we know about titanized polypropylene meshes? An evidence-based review of the literature.
    Köckerling F; Schug-Pass C
    Hernia; 2014 Aug; 18(4):445-57. PubMed ID: 24253381
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simple prosthesis versus prosthesis plus titanium-coated polypropylene mesh for implant-based immediate breast reconstruction after total mastectomy for breast cancer.
    Yao X; Guo Y; Tu Y; Yao F; Chen C; Sun S; Zhang X
    Gland Surg; 2019 Dec; 8(6):773-783. PubMed ID: 32042686
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pre-pectoral Breast Reconstruction Does Not Affect Early Immunological Response: A BIAL 2.20 Study Subanalysis.
    Vanni G; Pellicciaro M; Sadri A; Tacconi F; Materazzo M
    Anticancer Res; 2021 Nov; 41(11):5657-5665. PubMed ID: 34732439
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The in vivo biocompatibility of titanized polypropylene lightweight mesh is superior to that of conventional polypropylene mesh.
    Ai FF; Mao M; Zhang Y; Kang J; Zhu L
    Neurourol Urodyn; 2020 Jan; 39(1):96-107. PubMed ID: 31584215
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.