172 related articles for article (PubMed ID: 35458591)
1. The Facile Preparation of PBA-GO-CuO-Modified Electrochemical Biosensor Used for the Measurement of α-Amylase Inhibitors' Activity.
Li M; Yin X; Shan H; Meng C; Chen S; Yan Y
Molecules; 2022 Apr; 27(8):. PubMed ID: 35458591
[TBL] [Abstract][Full Text] [Related]
2. Synthesis of graphene oxide based CuO nanoparticles composite electrode for highly enhanced nonenzymatic glucose detection.
Song J; Xu L; Zhou C; Xing R; Dai Q; Liu D; Song H
ACS Appl Mater Interfaces; 2013 Dec; 5(24):12928-34. PubMed ID: 24182328
[TBL] [Abstract][Full Text] [Related]
3. Green synthesis of copper oxide nanoparticles decorated reduced graphene oxide for high sensitive detection of glucose.
Pourbeyram S; Abdollahpour J; Soltanpour M
Mater Sci Eng C Mater Biol Appl; 2019 Jan; 94():850-857. PubMed ID: 30423771
[TBL] [Abstract][Full Text] [Related]
4. Molecular imprinting method for fabricating novel glucose sensor: polyvinyl acetate electrode reinforced by MnO2/CuO loaded on graphene oxide nanoparticles.
Farid MM; Goudini L; Piri F; Zamani A; Saadati F
Food Chem; 2016 Mar; 194():61-7. PubMed ID: 26471527
[TBL] [Abstract][Full Text] [Related]
5. Non-enzymatic glucose sensor based on a g-C
Lotfi Z; Gholivand MB; Shamsipur M
Anal Biochem; 2021 Mar; 616():114062. PubMed ID: 33285122
[TBL] [Abstract][Full Text] [Related]
6. Biogenic synthesis of CuO/ZnO nanocomposite from Bauhinia variegate flower extract for highly sensitive electrochemical detection of vitamin B
Singh D; Verma R; Singh KR; Srivastava M; Singh RP; Singh J
Biomater Adv; 2024 Jul; 161():213898. PubMed ID: 38796957
[TBL] [Abstract][Full Text] [Related]
7. Graphene-Oxide-Based Electrochemical Sensors for the Sensitive Detection of Pharmaceutical Drug Naproxen.
Qian L; Thiruppathi AR; Elmahdy R; van der Zalm J; Chen A
Sensors (Basel); 2020 Feb; 20(5):. PubMed ID: 32106566
[TBL] [Abstract][Full Text] [Related]
8. A highly sensitive nonenzymatic glucose sensor based on CuO nanoparticles-modified carbon nanotube electrode.
Jiang LC; Zhang WD
Biosens Bioelectron; 2010 Feb; 25(6):1402-7. PubMed ID: 19942424
[TBL] [Abstract][Full Text] [Related]
9. Novel Electrochemical Sensors Based on Cuprous Oxide-Electrochemically Reduced Graphene Oxide Nanocomposites Modified Electrode toward Sensitive Detection of Sunset Yellow.
He Q; Liu J; Liu X; Xia Y; Li G; Deng P; Chen D
Molecules; 2018 Aug; 23(9):. PubMed ID: 30149513
[TBL] [Abstract][Full Text] [Related]
10. A novel nonenzymatic sensor based on CuO nanoneedle/graphene/carbon nanofiber modified electrode for probing glucose in saliva.
Ye D; Liang G; Li H; Luo J; Zhang S; Chen H; Kong J
Talanta; 2013 Nov; 116():223-30. PubMed ID: 24148397
[TBL] [Abstract][Full Text] [Related]
11. A high-performance nonenzymatic glucose sensor made of CuO-SWCNT nanocomposites.
Quoc Dung N; Patil D; Jung H; Kim D
Biosens Bioelectron; 2013 Apr; 42():280-6. PubMed ID: 23208099
[TBL] [Abstract][Full Text] [Related]
12. Novel electrochemical synthesis of copper oxide nanoparticles decorated graphene-β-cyclodextrin composite for trace-level detection of antibiotic drug metronidazole.
Velusamy V; Palanisamy S; Kokulnathan T; Chen SW; Yang TCK; Banks CE; Pramanik SK
J Colloid Interface Sci; 2018 Nov; 530():37-45. PubMed ID: 29960906
[TBL] [Abstract][Full Text] [Related]
13. Nonenzymatic amperometric determination of glucose by CuO nanocubes-graphene nanocomposite modified electrode.
Luo L; Zhu L; Wang Z
Bioelectrochemistry; 2012 Dec; 88():156-63. PubMed ID: 22522031
[TBL] [Abstract][Full Text] [Related]
14. Preparation of hexagonal boron nitride doped graphene film modified sensor for selective electrochemical detection of nicotine in tobacco sample.
Jerome R; Sundramoorthy AK
Anal Chim Acta; 2020 Oct; 1132():110-120. PubMed ID: 32980101
[TBL] [Abstract][Full Text] [Related]
15. Highly sensitive nonenzymatic glucose sensor based on electrospun copper oxide-doped nickel oxide composite microfibers.
Cao F; Guo S; Ma H; Yang G; Yang S; Gong J
Talanta; 2011 Oct; 86():214-20. PubMed ID: 22063533
[TBL] [Abstract][Full Text] [Related]
16. Nonenzymatic glucose sensor based on CuO microfibers composed of CuO nanoparticles.
Cao F; Gong J
Anal Chim Acta; 2012 Apr; 723():39-44. PubMed ID: 22444571
[TBL] [Abstract][Full Text] [Related]
17. Reduced graphene oxide decorated on Cu/CuO-Ag nanocomposite as a high-performance material for the construction of a non-enzymatic sensor: Application to the determination of carbaryl and fenamiphos pesticides.
Hashemi P; Karimian N; Khoshsafar H; Arduini F; Mesri M; Afkhami A; Bagheri H
Mater Sci Eng C Mater Biol Appl; 2019 Sep; 102():764-772. PubMed ID: 31147049
[TBL] [Abstract][Full Text] [Related]
18. Microwave synthesis of 3D rambutan-like CuO and CuO/reduced graphene oxide modified electrodes for non-enzymatic glucose detection.
Zheng J; Zhang W; Lin Z; Wei C; Yang W; Dong P; Yan Y; Hu S
J Mater Chem B; 2016 Feb; 4(7):1247-1253. PubMed ID: 32262980
[TBL] [Abstract][Full Text] [Related]
19. A non-enzymatic disposable electrochemical sensor based on surface-modified screen-printed electrode CuO-IL/rGO nanocomposite for a single-step determination of glucose in human urine and electrolyte drinks.
Janmee N; Preechakasedkit P; Rodthongkum N; Chailapakul O; Potiyaraj P; Ruecha N
Anal Methods; 2021 Jul; 13(25):2796-2803. PubMed ID: 34114570
[TBL] [Abstract][Full Text] [Related]
20. Facet-energy inspired metal oxide extended hexapods decorated with graphene quantum dots: sensitive detection of bisphenol A in live cells.
Ashraf G; Asif M; Aziz A; Dao AQ; Zhang T; Iftikhar T; Wang Q; Liu H
Nanoscale; 2020 Apr; 12(16):9014-9023. PubMed ID: 32270807
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]