134 related articles for article (PubMed ID: 35461124)
1. Uncertainty of LiF thermoluminescence at low dose levels: Experimental results.
Sadek AM; Abdou NY; Alazab HA
Appl Radiat Isot; 2022 Jul; 185():110245. PubMed ID: 35461124
[TBL] [Abstract][Full Text] [Related]
2. The thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF:Mg,Ti (TLD-100).
Horowitz YS; Oster L; Datz H
Radiat Prot Dosimetry; 2007; 124(2):191-205. PubMed ID: 17616543
[TBL] [Abstract][Full Text] [Related]
3. A comparative study on the susceptibility of LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (TLD-100H) to spurious signals in thermoluminescence dosimetry.
Al-Haj A; Lagarde C; Mahyoub F
Radiat Prot Dosimetry; 2007; 125(1-4):399-402. PubMed ID: 17223633
[TBL] [Abstract][Full Text] [Related]
4. The effect of cooling rate on the precision of measurement of glow peak 5 in the thermoluminescence of LiF:Mg,Ti (TLD-100).
Bokobza Y; Biderman S; Horowitz YS; Oster L; Eliyahu I; Shapiro A; Nemirovsky D; Reshes G; Herman B; Einav H
Radiat Prot Dosimetry; 2024 Mar; 200(4):423-427. PubMed ID: 38195760
[TBL] [Abstract][Full Text] [Related]
5. Investigation of the emission spectra of LiF:Mg,Ti (TLD-100) during thermoluminescence.
Biderman S; Horowitz Y; Oster L
Radiat Prot Dosimetry; 2002; 100(1-4):369-72. PubMed ID: 12382900
[TBL] [Abstract][Full Text] [Related]
6. Properties of the 4.45 eV optical absorption band in LiF:Mg,Ti.
Nail I; Oster L; Horowitz YS; Biderman S; Belaish Y
Radiat Prot Dosimetry; 2006; 119(1-4):244-7. PubMed ID: 16644966
[TBL] [Abstract][Full Text] [Related]
7. A personal thermoluminescence dosimeter using LiF:Mg,Cu,Na,Si detectors for photon fields.
Jung H; Lee KJ; Kim JL
Appl Radiat Isot; 2003 Jul; 59(1):87-93. PubMed ID: 12878128
[TBL] [Abstract][Full Text] [Related]
8. Thermoluminescence properties of LiF:Mg,Cu,Na,Si pellets in radiation dosimetry.
Nam YM; Kim JL
Radiat Prot Dosimetry; 2002; 100(1-4):467-70. PubMed ID: 12382923
[TBL] [Abstract][Full Text] [Related]
9. The zero signal and glow curves of bare LiF:Mg,Ti detectors in a hot gas TLD system.
van Dijk JW; Busscher FA
Radiat Prot Dosimetry; 2002; 101(1-4):59-64. PubMed ID: 12382705
[TBL] [Abstract][Full Text] [Related]
10. Analysis of the glow curves obtained from LiF:Mg,Cu,Na,Si TL material using the general order kinetics model.
Lee JI; Kim JL; Chang SY; Nam YM; Chung KS; Choe HS
Radiat Prot Dosimetry; 2002; 100(1-4):341-4. PubMed ID: 12382893
[TBL] [Abstract][Full Text] [Related]
11. THE THERMOLUMINESCENCE (TL) DOSE RESPONSE OF COMPOSITE PEAK 5 IN LIF:MG,TI (TLD-100): DEPENDENCE ON THE ORDER OF KINETICS.
Nemirovsky D; Oster L; Reshes G; Biderman S; Bokobza Y; Sterenberg M; Eliyahu I; Shapiro A; Herman B; Horowitz Y
Radiat Prot Dosimetry; 2023 Apr; 199(6):498-508. PubMed ID: 36856703
[TBL] [Abstract][Full Text] [Related]
12. Alpha particle and proton relative thermoluminescence efficiencies in LiF:Mg,Cu,P:is track structure theory up to the task?
Horowitz YS; Siboni D; Oster L; Livingstone J; Guatelli S; Rosenfeld A; Emfietzoglou D; Bilski P; Obryk B
Radiat Prot Dosimetry; 2012 Jul; 150(3):359-74. PubMed ID: 22042968
[TBL] [Abstract][Full Text] [Related]
13. Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an 192Ir brachytherapy source.
Lucas PA; Aubineau-Lanièce I; Lourenço V; Vermesse D; Cutarella D
Med Phys; 2014 Jan; 41(1):011711. PubMed ID: 24387503
[TBL] [Abstract][Full Text] [Related]
14. REVIEW OF DOSE-RATE EFFECTS IN THE THERMOLUMINESCENCE OF Lif:mg,ti (HARSHAW).
Horowitz Y; Oster L; Eliyahu I
Radiat Prot Dosimetry; 2018 Apr; 179(2):184-188. PubMed ID: 29145646
[TBL] [Abstract][Full Text] [Related]
15. Assessment of the mean glandular dose using LiF:Mg,Ti, LiF:Mg,Cu,P, Li2B4O7:Mn and Li2B4O7:Cu TL detectors in mammography radiation fields.
Fartaria MJ; Reis C; Pereira J; Pereira MF; Cardoso JV; Santos LM; Oliveira C; Holovey V; Pascoal A; Alves JG
Phys Med Biol; 2016 Sep; 61(17):6384-99. PubMed ID: 27499104
[TBL] [Abstract][Full Text] [Related]
16. Thermoluminescent response of LiF:Mg,Ti to 20 keV electrons.
Mercado-Uribe H; Brandan ME
Radiat Prot Dosimetry; 2002; 100(1-4):179-82. PubMed ID: 12382856
[TBL] [Abstract][Full Text] [Related]
17. The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions.
Moscovitch M; St John TJ; Cassata JR; Blake PK; Rotunda JE; Ramlo M; Velbeck KJ; Luo LZ
Radiat Prot Dosimetry; 2006; 119(1-4):248-54. PubMed ID: 16835277
[TBL] [Abstract][Full Text] [Related]
18. Comments to the author's response to our letter on "The thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF:Mg,Ti (TLD-100)" by Y.S. Horowitz, L. Oster and H. Datz.
German U; Weinstein M; Abraham A; Alfassi ZB
Radiat Prot Dosimetry; 2008; 129(4):495-7; author reply 497. PubMed ID: 18650206
[No Abstract] [Full Text] [Related]
19. FADING EFFECT OF LiF:Mg,Ti AND LiF:Mg,Cu,P Ext-Rad AND WHOLE-BODY DETECTORS.
Pereira J; Pereira MF; Rangel S; Saraiva M; Santos LM; Cardoso JV; Alves JG
Radiat Prot Dosimetry; 2016 Sep; 170(1-4):177-80. PubMed ID: 26503857
[TBL] [Abstract][Full Text] [Related]
20. Comments on 'The thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF: Mg.Ti (TLD-100)' by Y.S. Horowitz, L. Oster and H. Datz.
German U; Weinstein M; Abraham A; Alfassi ZB
Radiat Prot Dosimetry; 2008; 128(4):509-10; author reply 510-5. PubMed ID: 18420571
[No Abstract] [Full Text] [Related]
[Next] [New Search]