BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 35468352)

  • 1. Comparison of bone marrow trephine sample quality between a drill-powered system and a manual needle system.
    Mihailescu SD; Jaselme P; Fontoura ML; Feddag-Hannachi L; Veresezan EL; Drieux F; Camus V; Bouclet F; Tilly H; Cardinaël N; Jardin F
    Ann Diagn Pathol; 2022 Aug; 59():151952. PubMed ID: 35468352
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of the bone marrow trephine sample quality between OnControl drill system and the Jamshidi needle.
    Forwood KM; Lee E; Crispin PJ
    Int J Lab Hematol; 2019 Jun; 41(3):373-379. PubMed ID: 30779423
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bone marrow biopsies performed by both the powered OnControl drill device and the Jamshidi needle produce adequate specimens.
    Jain S; Enzerra M; Mehta RS; Smith R; Djokic M
    J Clin Pathol; 2017 Jun; 70(6):541-543. PubMed ID: 28062659
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Efficacy and safety of bone marrow aspiration and biopsy using fluoroscopic guidance and a drill-powered needle: clinical experience from 775 cases.
    Long JR; Stensby JD; Wiesner EL; Bryson WN; Hillen TJ; Jennings JW
    Eur Radiol; 2020 Nov; 30(11):5964-5970. PubMed ID: 32518988
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Using a powered bone marrow biopsy system results in shorter procedures, causes less residual pain to adult patients, and yields larger specimens.
    Berenson JR; Yellin O; Blumenstein B; Bojanower D; Croopnick J; Aboulafia D; Upadhyaya G; Spadaccini C
    Diagn Pathol; 2011 Mar; 6():23. PubMed ID: 21429220
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improving bone marrow biopsy quality through peer discussion and data comparisons: A single institution experience.
    Yang RK; Nazeef M; Patel SS; Mattison R; Yang DT; Ranheim EA; Leith CP
    Int J Lab Hematol; 2018 Aug; 40(4):419-426. PubMed ID: 29575638
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A prospective survey on trephine biopsy of bone and bone marrow: an experience with 274 Indian patients' biopsies.
    Nadda R; Repaka R; Mallik N; Sahani AK
    Eur J Med Res; 2023 Jun; 28(1):193. PubMed ID: 37353842
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of powered drill & manual bone biopsy systems: Does the diagnostic yield justify the cost?
    Huh EH; Yi PH; Ray DM; Hsu LCH; Hui FK; Khan M
    J Clin Neurosci; 2020 Mar; 73():125-129. PubMed ID: 31992515
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of a powered bone marrow biopsy device with a manual system: results of a prospective randomised controlled trial.
    Bucher CM; Lehmann T; Tichelli A; Tzankov A; Dirnhofer S; Passweg J; Rovó A
    J Clin Pathol; 2013 Jan; 66(1):24-8. PubMed ID: 23105124
    [TBL] [Abstract][Full Text] [Related]  

  • 10. (18)F-FDG PET/CT bone/bone marrow findings in Hodgkin's lymphoma may circumvent the use of bone marrow trephine biopsy at diagnosis staging.
    Moulin-Romsee G; Hindié E; Cuenca X; Brice P; Decaudin D; Bénamor M; Brière J; Anitei M; Filmont JE; Sibon D; de Kerviler E; Moretti JL
    Eur J Nucl Med Mol Imaging; 2010 Jun; 37(6):1095-105. PubMed ID: 20204358
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A prospective randomised study of a rotary powered device (OnControl) for bone marrow aspiration and biopsy.
    Swords RT; Anguita J; Higgins RA; Yunes AC; Naski M; Padmanabhan S; Kelly KR; Mahalingam D; Philbeck T; Miller L; Puga TA; Giles FJ; Kinney MC; Brenner AJ
    J Clin Pathol; 2011 Sep; 64(9):809-13. PubMed ID: 21606230
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Can Positron Emission Tomography and Computed Tomography Be a Substitute for Bone Marrow Biopsy in Detection of Bone Marrow Involvement in Patients with Hodgkin's or Non-Hodgkin's Lymphoma?
    Çetin G; Çıkrıkçıoğlu MA; Özkan T; Karatoprak C; Ar MC; Eşkazan AE; Ayer M; Cerit A; Gözübenli K; Uysal BB; Erdem S; Ergül N; Tatar G; Çermik TF
    Turk J Haematol; 2015 Sep; 32(3):213-9. PubMed ID: 25912844
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reduction of Radiation Dose and Scanning Time While Preserving Diagnostic Yield: A Comparison of Battery-Powered and Manual Bone Biopsy Systems.
    Kihira S; Koo C; Lee A; Aggarwal A; Pawha P; Doshi A
    AJNR Am J Neuroradiol; 2020 Mar; 41(3):387-392. PubMed ID: 32029464
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions.
    Cohen MG; McMahon CJ; Kung JW; Wu JS
    AJR Am J Roentgenol; 2016 May; 206(5):W83-6. PubMed ID: 26959290
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In newly diagnosed diffuse large B-cell lymphoma, determination of bone marrow involvement with 18F-FDG PET/CT provides better diagnostic performance and prognostic stratification than does biopsy.
    Berthet L; Cochet A; Kanoun S; Berriolo-Riedinger A; Humbert O; Toubeau M; Dygai-Cochet I; Legouge C; Casasnovas O; Brunotte F
    J Nucl Med; 2013 Aug; 54(8):1244-50. PubMed ID: 23674577
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of flow cytometry, bone marrow biopsy, and bone marrow aspirates in the detection of lymphoid infiltration in B cell disorders.
    Sah SP; Matutes E; Wotherspoon AC; Morilla R; Catovsky D
    J Clin Pathol; 2003 Feb; 56(2):129-32. PubMed ID: 12560392
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of bone marrow in 143 lymphomas: the relative frequency and pattern of involvement, secondary myelopathies, pitfalls and diagnostic validity.
    El Bolkainy TM; Abo Deif WS; Gouda HM; Mokhtar NM
    J Egypt Natl Canc Inst; 2008 Mar; 20(1):17-30. PubMed ID: 19847278
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Differences in Radiation Exposure of CT-Guided Percutaneous Manual and Powered Drill Bone Biopsy.
    Zensen S; Selvaretnam S; Opitz M; Bos D; Haubold J; Theysohn J; Forsting M; Guberina N; Wetter A
    Cardiovasc Intervent Radiol; 2021 Sep; 44(9):1430-1438. PubMed ID: 33977330
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Adequacy of powered vs manual bone marrow biopsy specimens: a retrospective review of sequential marrow aspirates and biopsies in 68 patients.
    Lynch DW; Stauffer SL; Rosenthal NS
    Am J Clin Pathol; 2015 Apr; 143(4):535-9. PubMed ID: 25780005
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bone marrow trephine biopsies from posterior superior iliac crest in neonates.
    Bartakke S; Lukade U; Sethuratnam S
    Pediatr Blood Cancer; 2021 Apr; 68(4):e28893. PubMed ID: 33484072
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.