These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 35471025)

  • 1. Evaluating the Effects of Metal Adduction and Charge Isomerism on Ion-Mobility Measurements using
    Oluwatoba DS; Islam MF; Som B; Sindt AJ; Smith MD; Shimizu LS; Do TD
    J Am Soc Mass Spectrom; 2022 May; 33(5):840-850. PubMed ID: 35471025
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ion mobility studies of carbohydrates as group I adducts: isomer specific collisional cross section dependence on metal ion radius.
    Huang Y; Dodds ED
    Anal Chem; 2013 Oct; 85(20):9728-35. PubMed ID: 24033309
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of drift gas on collision cross sections of a protein standard in linear drift tube and traveling wave ion mobility mass spectrometry.
    Jurneczko E; Kalapothakis J; Campuzano ID; Morris M; Barran PE
    Anal Chem; 2012 Oct; 84(20):8524-31. PubMed ID: 22974196
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Application of Group I Metal Adduction to the Separation of Steroids by Traveling Wave Ion Mobility Spectrometry.
    Rister AL; Martin TL; Dodds ED
    J Am Soc Mass Spectrom; 2019 Feb; 30(2):248-255. PubMed ID: 30414066
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Conformational ordering of biomolecules in the gas phase: nitrogen collision cross sections measured on a prototype high resolution drift tube ion mobility-mass spectrometer.
    May JC; Goodwin CR; Lareau NM; Leaptrot KL; Morris CB; Kurulugama RT; Mordehai A; Klein C; Barry W; Darland E; Overney G; Imatani K; Stafford GC; Fjeldsted JC; McLean JA
    Anal Chem; 2014 Feb; 86(4):2107-16. PubMed ID: 24446877
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of metal ion adduction on the gas-phase conformations of protein ions.
    Flick TG; Merenbloom SI; Williams ER
    J Am Soc Mass Spectrom; 2013 Nov; 24(11):1654-62. PubMed ID: 23733259
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluating Separation Selectivity and Collision Cross Section Measurement Reproducibility in Helium, Nitrogen, Argon, and Carbon Dioxide Drift Gases for Drift Tube Ion Mobility-Mass Spectrometry.
    Morris CB; May JC; Leaptrot KL; McLean JA
    J Am Soc Mass Spectrom; 2019 Jun; 30(6):1059-1068. PubMed ID: 30887459
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High-field asymmetric waveform ion mobility spectrometry for xylene isomer separation assisted by helium-chemical modifiers.
    Du X; Wang Y; Zeng H; Zeng H; Chen Z; Li H
    Anal Methods; 2022 Nov; 14(45):4649-4658. PubMed ID: 36377690
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Gas molecule scattering & ion mobility measurements for organic macro-ions in He versus N2 environments.
    Larriba-Andaluz C; Fernández-García J; Ewing MA; Hogan CJ; Clemmer DE
    Phys Chem Chem Phys; 2015 Jun; 17(22):15019-29. PubMed ID: 25988389
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Structural resolution of 4-substituted proline diastereomers with ion mobility spectrometry via alkali metal ion cationization.
    Flick TG; Campuzano ID; Bartberger MD
    Anal Chem; 2015 Mar; 87(6):3300-7. PubMed ID: 25664640
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ion mobility mass spectrometry - an efficient tool for the analysis of conformational switch of macrocyclic receptors upon anion binding.
    Zimnicka M; Kalenius E; Jurczak J; Danikiewicz W
    Analyst; 2021 Sep; 146(17):5337-5346. PubMed ID: 34323262
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improved separation of fentanyl isomers using metal cation adducts and high-resolution ion mobility-mass spectrometry.
    Aderorho R; Chouinard CD
    Drug Test Anal; 2024 Apr; 16(4):369-379. PubMed ID: 37491787
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ion Mobility of Proteins in Nitrogen Gas: Effects of Charge State, Charge Distribution, and Structure.
    Canzani D; Laszlo KJ; Bush MF
    J Phys Chem A; 2018 Jun; 122(25):5625-5634. PubMed ID: 29864282
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Separation of biologically relevant isomers on an Orbitrap mass spectrometer using high-resolution drift tube ion mobility and varied drift gas mixtures.
    Kaszycki JL; La Rotta A; Colsch B; Fenaille F; Dauly C; Kamleh A; Wu C
    Rapid Commun Mass Spectrom; 2019 Jul; 33 Suppl 2():3-10. PubMed ID: 30772932
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Conformational Landscapes of Ubiquitin, Cytochrome c, and Myoglobin: Uniform Field Ion Mobility Measurements in Helium and Nitrogen Drift Gas.
    May JC; Jurneczko E; Stow SM; Kratochvil I; Kalkhof S; McLean JA
    Int J Mass Spectrom; 2018 Apr; 427():79-90. PubMed ID: 29915518
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Separation of isomeric amines with ion mobility spectrometry.
    Laakia J; Kauppila TJ; Adamov A; Sysoev AA; Kotiaho T
    Talanta; 2015 Jan; 132():889-93. PubMed ID: 25476393
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simultaneous Differentiation of C═C Position Isomerism in Fatty Acids through Ion Mobility and Theoretical Calculations.
    Wu F; Wu X; Chi C; Ding CF
    Anal Chem; 2022 Sep; 94(35):12213-12220. PubMed ID: 36008361
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of drift gas selection in complex sample analyses using a high performance drift tube ion mobility-QTOF mass spectrometer.
    Kurulugama RT; Darland E; Kuhlmann F; Stafford G; Fjeldsted J
    Analyst; 2015 Oct; 140(20):6834-44. PubMed ID: 26178817
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessing the Impact of Drift Gas Polarizability in Polyatomic Ion Mobility Experiments.
    Naylor CN; Reinecke T; Clowers BH
    Anal Chem; 2020 Mar; 92(6):4226-4234. PubMed ID: 32058698
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of adduct formation with molecular nitrogen on the measured collisional cross sections of transition metal-1,10-phenanthroline complexes in traveling wave ion-mobility spectrometry: N2 is not always an "inert" buffer gas.
    Rijs NJ; Weiske T; Schlangen M; Schwarz H
    Anal Chem; 2015 Oct; 87(19):9769-76. PubMed ID: 26378338
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.