These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 35482002)

  • 21. Use of Electrical Impedance Tomography (EIT) to Estimate Global and Regional Lung Recruitment Volume (VREC) Induced by Positive End-Expiratory Pressure (PEEP): An Experiment in Pigs with Lung Injury.
    Wang YM; Sun XM; Zhou YM; Chen JR; Cheng KM; Li HL; Yang YL; Zhang L; Zhou JX
    Med Sci Monit; 2020 Mar; 26():e922609. PubMed ID: 32172276
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Electrical impedance tomography as a tool for monitoring mechanical ventilation. An introduction to the technique.
    Maciejewski D; Putowski Z; Czok M; Krzych ŁJ
    Adv Med Sci; 2021 Sep; 66(2):388-395. PubMed ID: 34371248
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Expert opinion document: "Electrical impedance tomography: applications from the intensive care unit and beyond".
    Rauseo M; Spinelli E; Sella N; Slobod D; Spadaro S; Longhini F; Giarratano A; Gilda C; Mauri T; Navalesi P;
    J Anesth Analg Crit Care; 2022 Jun; 2(1):28. PubMed ID: 37386674
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Electrical impedance tomography in adult patients undergoing mechanical ventilation: A systematic review.
    Kobylianskii J; Murray A; Brace D; Goligher E; Fan E
    J Crit Care; 2016 Oct; 35():33-50. PubMed ID: 27481734
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Electrical Impedance Tomography for Cardio-Pulmonary Monitoring.
    Putensen C; Hentze B; Muenster S; Muders T
    J Clin Med; 2019 Aug; 8(8):. PubMed ID: 31394721
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Influence of different electrode belt positions on electrical impedance tomography imaging of regional ventilation: a prospective observational study.
    Karsten J; Stueber T; Voigt N; Teschner E; Heinze H
    Crit Care; 2016 Jan; 20():3. PubMed ID: 26743570
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Event-triggered averaging of electrical impedance tomography (EIT) respiratory waveforms as compared to low-pass filtering for removal of cardiac related impedance changes.
    Coppadoro A; Eronia N; Foti G; Bellani G
    J Clin Monit Comput; 2020 Jun; 34(3):553-558. PubMed ID: 31278546
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Clinical Scenarios of the Application of Electrical Impedance Tomography in Paediatric Intensive Care.
    Davies P; Yasin S; Gates S; Bird D; Silvestre C
    Sci Rep; 2019 Mar; 9(1):5362. PubMed ID: 30926828
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Bedside monitoring of lung perfusion by electrical impedance tomography].
    Wang YX; Zhong M
    Zhonghua Yi Xue Za Zhi; 2022 Sep; 102(36):2828-2833. PubMed ID: 36153867
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Lung monitoring at the bedside in mechanically ventilated patients.
    Blankman P; Gommers D
    Curr Opin Crit Care; 2012 Jun; 18(3):261-6. PubMed ID: 22543298
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Regional expiratory time constants in severe respiratory failure estimated by electrical impedance tomography: a feasibility study.
    Karagiannidis C; Waldmann AD; Róka PL; Schreiber T; Strassmann S; Windisch W; Böhm SH
    Crit Care; 2018 Sep; 22(1):221. PubMed ID: 30236123
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of regional ventilation by electric impedance tomography during percutaneous dilatational tracheostomy in neurocritical care: a pilot study.
    Spatenkova V; Teschner E; Jedlicka J
    BMC Neurol; 2020 Oct; 20(1):374. PubMed ID: 33045989
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Electrical impedance tomography: ready for routine clinical use for mechanically ventilated patients?].
    Hinz J; Hahn G; Quintel M
    Anaesthesist; 2008 Jan; 57(1):61-9. PubMed ID: 17934702
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A review on electrical impedance tomography for pulmonary perfusion imaging.
    Nguyen DT; Jin C; Thiagalingam A; McEwan AL
    Physiol Meas; 2012 May; 33(5):695-706. PubMed ID: 22532291
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Electrical impedance tomography: potentials and pitfalls.
    Lundin S; Stenqvist O
    Curr Opin Crit Care; 2012 Feb; 18(1):35-41. PubMed ID: 22201705
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Clinical implication of monitoring regional ventilation using electrical impedance tomography.
    Shono A; Kotani T
    J Intensive Care; 2019; 7():4. PubMed ID: 30680219
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial.
    Bikker IG; Preis C; Egal M; Bakker J; Gommers D
    Crit Care; 2011 Aug; 15(4):R193. PubMed ID: 21834953
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Distribution of Ventilation Measured by Electrical Impedance Tomography in Critically Ill Children.
    Inany HS; Rettig JS; Smallwood CD; Arnold JH; Walsh BK
    Respir Care; 2020 May; 65(5):590-595. PubMed ID: 31992677
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Electrical impedance tomography: a method for monitoring regional lung aeration and tidal volume distribution?
    Frerichs I; Dargaville PA; Dudykevych T; Rimensberger PC
    Intensive Care Med; 2003 Dec; 29(12):2312-2316. PubMed ID: 14566457
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Protective ventilation using electrical impedance tomography.
    Luepschen H; Meier T; Grossherr M; Leibecke T; Karsten J; Leonhardt S
    Physiol Meas; 2007 Jul; 28(7):S247-60. PubMed ID: 17664639
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.