159 related articles for article (PubMed ID: 35487635)
1. Emergent option in complicated acute type B aortic dissection.
Nakabayashi K; Shimizu T; Takahashi K; Ando H
BMJ Case Rep; 2022 Apr; 15(4):. PubMed ID: 35487635
[TBL] [Abstract][Full Text] [Related]
2. Intravascular Ultrasound-Assisted Endovascular Treatment of Mesenteric Malperfusion in a Multichannel Aortic Dissection With Full True Lumen Collapse.
Guo B; Guo D; Shi Z; Dong Z; Fu W
J Endovasc Ther; 2019 Feb; 26(1):83-87. PubMed ID: 30547707
[TBL] [Abstract][Full Text] [Related]
3. [Optimal Management of Stanford Type A Acute Aortic Dissection with Mesenteric Malperfusion].
Inoue T; Ichihara T; Masuyama S; Nakamura M
Kyobu Geka; 2023 Mar; 76(3):179-187. PubMed ID: 36861272
[TBL] [Abstract][Full Text] [Related]
4. Early superior mesenteric artery revascularization for acute type A aortic dissection with cardiac tamponade and mesenteric malperfusion.
Kusadokoro S; Kimura N; Miyoshi K; Hori D; Shiraishi M; Yamaguchi A
J Card Surg; 2020 Dec; 35(12):3581-3584. PubMed ID: 32906189
[TBL] [Abstract][Full Text] [Related]
5. Delayed bowel necrosis due to inferior mesenteric artery occlusion in Stanford type A acute aortic dissection.
Kawaguchi Y; Fukumoto Y; Tamaki M; Kitamura H
Interact Cardiovasc Thorac Surg; 2022 Nov; 35(6):. PubMed ID: 36282531
[TBL] [Abstract][Full Text] [Related]
6. Type A aortic dissection involving the superior mesenteric artery with peripheral malperfusion managed with a hybrid approach: a case report.
Cheng M; Lee KY
Hong Kong Med J; 2019 Oct; 25(5):403-405. PubMed ID: 31761751
[No Abstract] [Full Text] [Related]
7. Experience of the Zenith Dissection Endovascular System in the emergency setting of malperfusion in acute type B dissections.
Alsac JM; Girault A; El Batti S; Abou Rjeili M; Alomran F; Achouh P; Julia P; Fabiani JN
J Vasc Surg; 2014 Mar; 59(3):645-50. PubMed ID: 24246535
[TBL] [Abstract][Full Text] [Related]
8. Value of endovascular stent placement for symptomatic spontaneous isolated superior mesenteric artery dissection.
Pang P; Jiang Z; Huang M; Zhou B; Zhu K; Shan H
Eur J Radiol; 2013 Mar; 82(3):490-6. PubMed ID: 23092539
[TBL] [Abstract][Full Text] [Related]
9. Long-term results of combined surgical and radiological intervention in complicated aortic dissection type-A. A case report.
Cwikiel W; Harnek J; Dobre M
Acta Radiol; 2001 Jul; 42(4):393-7. PubMed ID: 11442464
[TBL] [Abstract][Full Text] [Related]
10. Morphologic characteristics and endovascular management of acute type B dissection patients with superior mesenteric artery involvement.
Lu W; Fu W; Wang L; Guo D; Xu X; Chen B; Jiang J
J Vasc Surg; 2021 Aug; 74(2):528-536.e2. PubMed ID: 33548440
[TBL] [Abstract][Full Text] [Related]
11. Acute mesenteric ischemia caused by spontaneous isolated dissection of the superior mesenteric artery: treatment by percutaneous stent placement.
Leung DA; Schneider E; Kubik-Huch R; Marincek B; Pfammatter T
Eur Radiol; 2000; 10(12):1916-9. PubMed ID: 11305570
[TBL] [Abstract][Full Text] [Related]
12. Thoracic endovascular aortic repair with stent grafts alone or with a composite device design in patients with acute type B aortic dissection in the setting of malperfusion.
Sobocinski J; Dias NV; Hongku K; Lombardi JV; Zhou Q; Saunders AT; Resch T; Haulon S
J Vasc Surg; 2020 Feb; 71(2):400-407.e2. PubMed ID: 31280979
[TBL] [Abstract][Full Text] [Related]
13. Use of the Octopus Endograft Technique to Reconstruct Renovisceral Arteries Arising From the False Lumen of a Rapidly Expanding Type B Aortic Dissection After Endovascular Repair.
Xiong J; Ge Y; Liu X; Wang L; Guo W
J Endovasc Ther; 2017 Feb; 24(1):107-111. PubMed ID: 27864460
[TBL] [Abstract][Full Text] [Related]
14. True lumen stenting for a spontaneously dissected superior mesenteric artery may compromise major intestinal branches and aggravate bowel ischemia.
Chang CF; Lai HC; Yao HY; Cheng YT; Lee WL; Wang KY; Liu TJ
Vasc Endovascular Surg; 2014 Jan; 48(1):83-5. PubMed ID: 24178731
[TBL] [Abstract][Full Text] [Related]
15. Relief of mesenteric ischemia by Z-stent placement into the superior mesenteric artery compressed by the false lumen of an aortic dissection.
Yamakado K; Takeda K; Nomura Y; Kato N; Hirano T; Matsumura K; Nakagawa T; Yuasa H; Yada I
Cardiovasc Intervent Radiol; 1998; 21(1):66-8. PubMed ID: 9473550
[TBL] [Abstract][Full Text] [Related]
16. Obstructive Stent Edge Dissection in Superior Mesenteric Artery: Out of the Frying Pan, Into the Fire!
Raju SN; Pandey NN; Shaw M; Malhi AS; Kumar S
J Endovasc Ther; 2022 Aug; 29(4):503-506. PubMed ID: 34704496
[No Abstract] [Full Text] [Related]
17. Long-term results of percutaneous management of malperfusion in acute type B aortic dissection: implications for thoracic aortic endovascular repair.
Patel HJ; Williams DM; Meerkov M; Dasika NL; Upchurch GR; Deeb GM
J Thorac Cardiovasc Surg; 2009 Aug; 138(2):300-8. PubMed ID: 19619770
[TBL] [Abstract][Full Text] [Related]
18. Surgical strategies for organ malperfusions in acute type B aortic dissection.
Uchida N; Shibamura H; Katayama A; Aishin K; Sutoh M; Kuraoka M
Interact Cardiovasc Thorac Surg; 2009 Jan; 8(1):75-8. PubMed ID: 18854338
[TBL] [Abstract][Full Text] [Related]
19. Emergent physician modified carotid fenestrated TEVAR for the treatment of a complicated acute type nonA-nonB aortic dissection with undetected multiorgan malperfusion.
Spath P; Stana J; Marazzi G; Peterss S; Fernandez-Prendes C; Tsilimparis N
J Cardiovasc Surg (Torino); 2023 Aug; 64(4):450-455. PubMed ID: 36168953
[TBL] [Abstract][Full Text] [Related]
20. Emergency bedside ultrasound diagnosis of superior mesenteric artery dissection complicating acute aortic dissection.
Davis CB; Kendall JL
J Emerg Med; 2013 Dec; 45(6):894-6. PubMed ID: 23932465
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]