BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

99 related articles for article (PubMed ID: 35500820)

  • 1. Procedural outcomes of the 34 mm EvolutR Transcatheter valve in a real-world population insights from the HORSE multicenter collaborative registry.
    Gallo F; Gallone G; Kim WK; Reifart J; Veulemans V; Zeus T; Toggweiler S; De Backer O; Søndergaard L; De Marco F; Regazzoli D; Reimers B; Muntané-Carol G; Estevez-Loureiro R; Hernandez U; Moscarelli M; Airale L; D'Ascenzo F; Armario X; Mylotte D; Bhadra OD; Conradi L; Donday LAM; Nombela-Franco L; Barbanti M; Reddavid C; Criscione E; Brugaletta S; Nicolini E; Piva T; Tzanis G; Ronco F; Barbierato M; Rodes-Cabau J; Mangieri A; Colombo A; Giannini F
    Int J Cardiol; 2022 Aug; 361():55-60. PubMed ID: 35500820
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Balloon Versus Self-Expandable Valve for the Treatment of Bicuspid Aortic Valve Stenosis: Insights From the BEAT International Collaborative Registrys.
    Mangieri A; Tchetchè D; Kim WK; Pagnesi M; Sinning JM; Landes U; Kornowski R; De Backer O; Nickenig G; Ielasi A; De Biase C; Søndergaard L; De Marco F; Montorfano M; Chiarito M; Regazzoli D; Stefanini G; Presbitero P; Toggweiler S; Tamburino C; Immè S; Tarantini G; Sievert H; Schäfer U; Kempfert J; Wöehrle J; Gallo F; Laricchia A; Latib A; Giannini F; Colombo A
    Circ Cardiovasc Interv; 2020 Jul; 13(7):e008714. PubMed ID: 32646304
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Early experience with the Evolut FX self-expanding valve vs. Evolut PRO+ for patients with aortic stenosis undergoing TAVR.
    Merdler I; Case B; Bhogal S; Reddy PK; Sawant V; Zhang C; Ali S; Ben-Dor I; Satler LF; Rogers T; Waksman R
    Cardiovasc Revasc Med; 2023 Nov; 56():1-6. PubMed ID: 37453813
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quantitative Angiographic Assessment of Aortic Regurgitation After Transcatheter Implantation of the Venus A-valve: Comparison with Other Self-Expanding Valves and Impact of a Learning Curve in a Single Chinese Center.
    Wang R; Kawashima H; Mylotte D; Rosseel L; Gao C; Aben JP; Abdelshafy M; Onuma Y; Yang J; Soliman O; Tao L; Serruys PW
    Glob Heart; 2021; 16(1):54. PubMed ID: 34381675
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparing two-year outcomes of balloon-expandable Myval and self-expanding Evolut R in severe aortic valve stenosis.
    Moscarella E; Ielasi A; Montonati C; Pellegrini D; Pellicano M; Briguglia D; D'Alessandro V; Giannini F; Gamardella M; Medda M; Guagliumi G; Banfi C; Glauber M; Tespili M
    Int J Cardiol; 2024 Apr; 400():131701. PubMed ID: 38168557
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evolut PRO and SAPIEN ULTRA Performance in Small Aortic Annuli: The OPERA-TAVI Registry.
    Scotti A; Sturla M; Costa G; Saia F; Pilgrim T; Abdel-Wahab M; Garot P; Gandolfo C; Branca L; Santos IA; Mylotte D; Bedogni F; De Backer O; Nombela Franco L; Webb J; Ribichini FL; Mainardi A; Andreaggi S; Mazzapicchi A; Tomii D; Laforgia P; Cannata S; Fiorina C; Fezzi S; Criscione E; Lunardi M; Poletti E; Mazzucca M; Quagliana A; Montarello N; Hennessey B; Mon-Noboa M; Akodad M; Meier D; De Marco F; Adamo M; Sgroi C; Reddavid CM; Valvo R; Strazzieri O; Motta SC; Frittitta V; Dipietro E; Comis A; Melfa C; Calì M; Sammartino S; Laterra G; Thiele H; Sondergaard L; Tamburino C; Barbanti M; Latib A
    JACC Cardiovasc Interv; 2024 Mar; 17(5):681-692. PubMed ID: 38479968
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optimal oversizing in transcatheter aortic valve replacement with the self-expanding Evolut valve system.
    Mas-Peiro S; Alperi A; Avvedimento M; Regueiro A; Avanzas P; Angellotti D; Esposito G; Vidal-Cales P; Mohammadi S; Farjat-Pasos J; Moris C; Rodés-Cabau J
    J Invasive Cardiol; 2024 Jun; 36(6):. PubMed ID: 38446025
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prosthesis Infolding Incidence and Short-Term Outcomes in Transcatheter Aortic Valve Implantation Using Evolut Self-Expandable Device: A Multicenter Study.
    Bezzeccheri A; Poletti E; Vermeersch P; Veulemans V; Piuhola J; Kerkelä S; Lehtola H; De Backer O; Quagliana A; Mammone C; Ribichini F; Prihadi E; Scott B; Zivelonghi C; Verheye S; Agostoni P
    Am J Cardiol; 2024 Jun; 221():102-109. PubMed ID: 38636623
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multicenter comparison of transcatheter aortic valve implantation with the self-expanding ACURATE neo2 versus Evolut PRO transcatheter heart valves.
    Rheude T; Pellegrini C; Landt M; Bleiziffer S; Wolf A; Renker M; Neuser J; Dörr O; Allali A; Rudolph TK; Wambach JM; Widder JD; Singh P; Berliner D; Alvarez-Covarrubias HA; Richardt G; Xhepa E; Kim WK; Joner M
    Clin Res Cardiol; 2024 Jan; 113(1):38-47. PubMed ID: 37115228
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Latest-iteration balloon- and self-expandable transcatheter valves for severe bicuspid aortic stenosis: the TRITON study.
    Amat-Santos IJ; García-Gómez M; de Marco F; Won-Keun K; Brito J; Halim J; Jose J; Sengotuvelu G; Seth A; Terkelsen C; Protasiewicz M; Bonilla N; García B; Sánchez-Luna JP; Blasco-Turrión S; González JC; González-Bartol E; Ijsselmuiden AJJ; Gómez-Salvador I; Carrasco Moraleja M; San Román A
    Rev Esp Cardiol (Engl Ed); 2023 Nov; 76(11):872-880. PubMed ID: 36898524
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Temporal Trends, Outcomes, and Predictors of Next-Day Discharge and Readmission Following Uncomplicated Evolut Transcatheter Aortic Valve Replacement: A Propensity Score-Matched Analysis.
    Batchelor WB; Sanchez CE; Sorajja P; Harvey JE; Galper BZ; Kini A; Keegan P; Grubb KJ; Eisenberg R; Rogers T
    J Am Heart Assoc; 2024 May; 13(9):e033846. PubMed ID: 38639328
    [TBL] [Abstract][Full Text] [Related]  

  • 12. LANDMARK comparison of early outcomes of newer-generation Myval transcatheter heart valve series with contemporary valves (Sapien and Evolut) in real-world individuals with severe symptomatic native aortic stenosis: a randomised non-inferiority trial.
    Baumbach A; van Royen N; Amat-Santos IJ; Hudec M; Bunc M; Ijsselmuiden A; Laanmets P; Unic D; Merkely B; Hermanides RS; Ninios V; Protasiewicz M; Rensing BJWM; Martin PL; Feres F; De Sousa Almeida M; van Belle E; Linke A; Ielasi A; Montorfano M; Webster M; Toutouzas K; Teiger E; Bedogni F; Voskuil M; Pan M; Angerås O; Kim WK; Rothe J; Kristić I; Peral V; Garg S; Elzomor H; Tobe A; Morice MC; Onuma Y; Soliman O; Serruys PW;
    Lancet; 2024 Jun; 403(10445):2695-2708. PubMed ID: 38795719
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of transcatheter aortic valve replacement with the ACURATE neo2 versus Evolut PRO/PRO+ devices.
    Baggio S; Pagnesi M; Kim WK; Scotti A; Barbanti M; Costa G; Adamo M; Kornowski R; Vaknin Assa H; Estévez-Loureiro R; Cedeño RA; De Marco F; Casenghi M; Toggweiler S; Veulemans V; Mylotte D; Lunardi M; Regazzoli D; Reimers B; Sondergaard L; Vanhaverbeke M; Nuyens P; Maffeo D; Buono A; Saccocci M; Giannini F; Di Ienno L; Ferlini M; Lanzillo G; Ielasi A; Schofer J; Brinkmann C; Van Der Heyden J; Buysschaert I; Eitan A; Wolf A; Adamaszek MM; Colombo A; Latib A; Mangieri A
    EuroIntervention; 2023 Jan; 18(12):977-986. PubMed ID: 36093795
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Self-Expanding Transcatheter Aortic Valves Optimize Transvalvular Hemodynamics Independent of Intra- Versus Supra-Annular Design.
    Brown JA; Yousef S; Toma C; Kliner D; Serna-Gallegos D; Makani A; West D; Wang Y; Thoma F; Pompeu Sá M; Sultan I
    Am J Cardiol; 2023 Nov; 207():48-53. PubMed ID: 37722201
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Coronary Cannulation Following TAVR Using Self-Expanding Devices With Commissural Alignment: The RE-ACCESS 2 Study.
    Costa G; Sammartino S; Strazzieri O; Motta S; Frittitta V; Dipietro E; Comis A; Calì M; Garretto V; Inserra C; Cannizzaro MT; Sgroi C; Tamburino C; Barbanti M
    JACC Cardiovasc Interv; 2024 Mar; 17(6):727-737. PubMed ID: 38456879
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The impact of cusp overlap on permanent pacemaker requirement following self-expanding transcatheter aortic valve replacement.
    Medranda GA; Rogers T; Case BC; Zhang C; Cellamare M; Shea C; Rappaport H; Cohen JE; Shults CC; Ben-Dor I; Satler LF; Waksman R
    Cardiovasc Revasc Med; 2024 Feb; 59():9-13. PubMed ID: 37550124
    [TBL] [Abstract][Full Text] [Related]  

  • 17. 5-Year Outcomes With Self-Expanding vs Balloon-Expandable Transcatheter Aortic Valve Replacement in Patients With Small Annuli.
    Okuno T; Tomii D; Lanz J; Heg D; Praz F; Stortecky S; Reineke D; Windecker S; Pilgrim T
    JACC Cardiovasc Interv; 2023 Feb; 16(4):429-440. PubMed ID: 36858662
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance of the 32 mm Myval transcatheter heart valve for treatment of aortic stenosis in patients with extremely large aortic annuli in real-world scenario: First global, multicenter experience.
    Holzamer A; Bedogni F; van Wyk P; Barwad P; Protasiewicz M; Ielasi A; Nombela-Franco L; Seidler T; Hilker M
    Catheter Cardiovasc Interv; 2023 Dec; 102(7):1364-1375. PubMed ID: 37698335
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of Paravalvular Leak in SAPIEN 3 and EVOLUT PRO Valves in Transcatheter Aortic Valve Replacement: A Multicenter Registry.
    Matta A; Regueiro A; Urena M; Nombela-Franco L; Riche M; Rodriguez-Gabella T; Amat-Santos I; Chamandi C; Akiki T; Gabani R; Vera-Urquiza R; Lhermusier T; Bouisset F; Carrié D; Campelo-Parada F
    Am J Cardiol; 2023 Nov; 207():114-120. PubMed ID: 37734300
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Incidence, Predictors, and Prognostic Impact of New Permanent Pacemaker Implantation After TAVR With Self-Expanding Valves.
    Pagnesi M; Kim WK; Baggio S; Scotti A; Barbanti M; De Marco F; Adamo M; Eitan A; Estévez-Loureiro R; Conradi L; Toggweiler S; Mylotte D; Veulemans V; Søndergaard L; Wolf A; Giannini F; Maffeo D; Pilgrim T; Montorfano M; Zweiker D; Ferlini M; Kornowski R; Hildick-Smith D; Taramasso M; Abizaid A; Schofer J; Sinning JM; Van Mieghem NM; Wöhrle J; Khogali S; Van der Heyden JAS; Wood DA; Ielasi A; MacCarthy P; Brugaletta S; Hamm CW; Costa G; Testa L; Massussi M; Alarcón R; Schäfer U; Brunner S; Reimers B; Lunardi M; Zeus T; Vanhaverbeke M; Naber CK; Di Ienno L; Buono A; Windecker S; Schmidt A; Lanzillo G; Vaknin-Assa H; Arunothayaraj S; Saccocci M; Siqueira D; Brinkmann C; Sedaghat A; Ziviello F; Seeger J; Rottbauer W; Brouwer J; Buysschaert I; Jelisejevas J; Bharucha A; Regueiro A; Metra M; Colombo A; Latib A; Mangieri A
    JACC Cardiovasc Interv; 2023 Aug; 16(16):2004-2017. PubMed ID: 37480891
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.