205 related articles for article (PubMed ID: 3550298)

  • 1. Valve failure caused by cusp tears in low-profile Ionescu-Shiley bovine pericardial bioprosthetic valves.
    Walley VM; Bédard P; Brais M; Keon WJ
    J Thorac Cardiovasc Surg; 1987 Apr; 93(4):583-6. PubMed ID: 3550298
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Patterns of failure in Ionescu-Shiley bovine pericardial bioprosthetic valves.
    Walley VM; Keon WJ
    J Thorac Cardiovasc Surg; 1987 Jun; 93(6):925-33. PubMed ID: 3573803
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fatigue-induced failure of the Ionescu-Shiley pericardial xenograft in the mitral position. In vivo and in vitro correlation and a proposed classification.
    Gabbay S; Bortolotti U; Wasserman F; Factor S; Strom J; Frater RW
    J Thorac Cardiovasc Surg; 1984 Jun; 87(6):836-44. PubMed ID: 6727407
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Reoperation for malfunction of Ionescu-Shiley bovine pericardial bioprosthetic valves in the mitral position--special consideration with emergency operation].
    Abe M; Sakai A; Hanayama N; Lin ZB; Oosawa M
    Nihon Kyobu Geka Gakkai Zasshi; 1997 Jan; 45(1):17-22. PubMed ID: 9028118
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Patterns of failure in Hancock pericardial bioprostheses.
    Walley VM; Rubens FD; Campagna M; Pipe AL; Keon WJ
    J Thorac Cardiovasc Surg; 1991 Aug; 102(2):187-94. PubMed ID: 1865694
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Noncalcific cusp thickening in Ionescu-Shiley cardiac valvular bioprostheses.
    Walley VM; Wolfsohn AL; Ghadially FN; Silver MM
    Mod Pathol; 1995 Feb; 8(2):121-9. PubMed ID: 7777471
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Late incidence and determinants of reoperation in patients with prosthetic heart valves.
    Ruel M; Kulik A; Rubens FD; Bédard P; Masters RG; Pipe AL; Mesana TG
    Eur J Cardiothorac Surg; 2004 Mar; 25(3):364-70. PubMed ID: 15019662
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of experience with the Hancock and Ionescu-Shiley low-profile pericardial bioprostheses.
    Reece IJ; Fisher J; Sethia B; MacArthur KJ; Wheatley DJ
    Z Kardiol; 1986; 75 Suppl 2():232-6. PubMed ID: 3727691
    [No Abstract]   [Full Text] [Related]  

  • 9. The role of pannus in the longevity of an Ionescu-Shiley pericardial bioprosthesis.
    Butany JW; Kesarwani R; Yau TM; Singh G; Thangaroopan M; Nair V; Leong SW
    J Card Surg; 2006; 21(5):505-7. PubMed ID: 16948773
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Long-term follow-up of the Ionescu-Shiley mitral pericardial xenograft.
    Gabbay S; Bortolotti U; Wasserman F; Tindel N; Factor SM; Frater RW
    J Thorac Cardiovasc Surg; 1984 Nov; 88(5 Pt 1):758-63. PubMed ID: 6492841
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pericardial heterografts: why do these valves fail?
    Trowbridge EA; Lawford PV; Crofts CE; Roberts KM
    J Thorac Cardiovasc Surg; 1988 Apr; 95(4):577-85. PubMed ID: 3352291
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Bioprosthesis degeneration in the aortic and mitral valve position. Results and problems from the cardiosurgical viewpoint].
    Antretter H; Cottogni M; Falbesoner C; Furtwängler W; Mair P; Falk M; Hutter J
    Wien Med Wochenschr; 1993; 143(11):281-7. PubMed ID: 8212714
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Twenty-six-year durability of an Ionescu-Shiley standard profile pericardial aortic valve.
    Honda K; Okamura Y; Nishimura Y; Uchita S
    Interact Cardiovasc Thorac Surg; 2010 Feb; 10(2):315-6. PubMed ID: 19914926
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Morphologic findings in explanted Hancock II porcine bioprostheses.
    Butany J; Yu W; Silver MD; David TE
    J Heart Valve Dis; 1999 Jan; 8(1):4-15. PubMed ID: 10096476
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ionescu-Shiley valve failure. II: Experience with 25 low-profile explants.
    Walley VM; Keon CA; Khalili M; Moher D; Campagna M; Keon WJ
    Ann Thorac Surg; 1992 Jul; 54(1):117-22; discussion 122-3. PubMed ID: 1610222
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cuspal perforations caused by long suture ends in implanted bioprosthetic valves.
    Jones M; Rodríguez ER; Eidbo EE; Ferrans VJ
    J Thorac Cardiovasc Surg; 1985 Oct; 90(4):557-63. PubMed ID: 3900589
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A morphologic study of Carpentier-Edwards pericardial xenografts in the mitral position exhibiting primary tissue failure in adults in comparison with Ionescu-Shiley pericardial xenografts.
    Machida H; Ishibashi-Ueda H; Nakano K; Sasako Y; Kobayashi J; Bando K; Minatoya K; Imamura H; Kitamura S
    J Thorac Cardiovasc Surg; 2001 Oct; 122(4):649-55. PubMed ID: 11581594
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Unusual 25-year durability of an Ionescu-Shiley pericardial bioprosthesis.
    Fiore A; Cooley DA; Grande AM; Viganò M; Angelini P
    Ann Thorac Surg; 2011 Apr; 91(4):e52-3. PubMed ID: 21440107
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Low profile bioprostheses for mitral valve replacement.
    Romano M; Sigal R; Lorente P; Piwnica A
    Z Kardiol; 1986; 75 Suppl 2():305-7. PubMed ID: 3727708
    [No Abstract]   [Full Text] [Related]  

  • 20. Biaxial strain distributions in explanted porcine bioprosthetic valves.
    Adamczyk MM; Vesely I
    J Heart Valve Dis; 2002 Sep; 11(5):688-95. PubMed ID: 12358406
    [TBL] [Abstract][Full Text] [Related]  