These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

294 related articles for article (PubMed ID: 35510408)

  • 1. In vivo porcine characterization of atrial lesion safety and efficacy utilizing a circular pulsed-field ablation catheter including assessment of collateral damage to adjacent tissue in supratherapeutic ablation applications.
    Hsu JC; Gibson D; Banker R; Doshi SK; Gidney B; Gomez T; Berman D; Datta K; Govari A; Natale A
    J Cardiovasc Electrophysiol; 2022 Jul; 33(7):1480-1488. PubMed ID: 35510408
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pulsed field ablation for pulmonary vein isolation: Preclinical safety and effectiveness of a novel hexaspline ablation catheter.
    Yu F; Dong X; Ding L; Reddy V; Tang M
    J Cardiovasc Electrophysiol; 2023 Nov; 34(11):2195-2202. PubMed ID: 37712346
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Preclinical evaluation of a novel single-shot pulsed field ablation system for pulmonary vein and atrial ablation.
    Aryana A; Ji SY; Hata C; de la Rama A; Nguyen K; Panescu D
    J Cardiovasc Electrophysiol; 2023 Nov; 34(11):2203-2212. PubMed ID: 37464948
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Paroxysmal Atrial Fibrillation Ablation Using a Novel Variable-Loop Biphasic Pulsed Field Ablation Catheter Integrated With a 3-Dimensional Mapping System: 1-Year Outcomes of the Multicenter inspIRE Study.
    Duytschaever M; De Potter T; Grimaldi M; Anic A; Vijgen J; Neuzil P; Van Herendael H; Verma A; Skanes A; Scherr D; Pürerfellner H; Rackauskas G; Jaïs P; Reddy VY;
    Circ Arrhythm Electrophysiol; 2023 Mar; 16(3):e011780. PubMed ID: 36735937
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 'Single-shot' pulmonary vein isolation using a novel lotos pulsed field ablation catheter: a pre-clinical evaluation of feasibility, safety, and 30-day efficacy.
    Pu S; Liu F; Chen Y; Luo C; Li P; Chen Y; Fu L; Liu H; Ye X; Wu S; Xue Y; Lin W
    Europace; 2023 Dec; 26(1):. PubMed ID: 38109928
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Preclinical assessment of the feasibility, safety and lesion durability of a novel 'single-shot' pulsed field ablation catheter for pulmonary vein isolation.
    Koruth J; Kawamura I; Dukkipati SR; Neuzil P; Reddy VY
    Europace; 2023 Apr; 25(4):1369-1378. PubMed ID: 36794699
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial Fibrillation.
    Reddy VY; Neuzil P; Koruth JS; Petru J; Funosako M; Cochet H; Sediva L; Chovanec M; Dukkipati SR; Jais P
    J Am Coll Cardiol; 2019 Jul; 74(3):315-326. PubMed ID: 31085321
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validation of a multipolar pulsed-field ablation catheter for endpoint assessment in pulmonary vein isolation procedures.
    Kueffer T; Baldinger SH; Servatius H; Madaffari A; Seiler J; Mühl A; Franzeck F; Thalmann G; Asatryan B; Haeberlin A; Noti F; Tanner H; Roten L; Reichlin T
    Europace; 2022 Sep; 24(8):1248-1255. PubMed ID: 35699395
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Time Course of Irreversible Electroporation Lesion Development Through Short- and Long-Term Follow-Up in Pulsed-Field Ablation-Treated Hearts.
    Grimaldi M; Di Monaco A; Gomez T; Berman D; Datta K; Sharma T; Govari A; Altmann A; Di Biase L
    Circ Arrhythm Electrophysiol; 2022 Jul; 15(7):e010661. PubMed ID: 35763432
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Point-by-Point Pulsed Field Ablation Using a Multimodality Generator and a Contact Force-Sensing Ablation Catheter: Comparison With Radiofrequency Ablation in a Remapped Chronic Swine Heart.
    Di Biase L; Marazzato J; Zou F; Lin A; Grupposo V; Chowdhuri N; Maffre J; Farshchi-Heydari S; Sharma T; Beeckler C; Govari A; Bhardwaj R; Mohanty S; Natale A; Nakagawa H; Zhang X
    Circ Arrhythm Electrophysiol; 2023 Dec; 16(12):663-671. PubMed ID: 37994554
    [TBL] [Abstract][Full Text] [Related]  

  • 11. First experience with pulsed field ablation as routine treatment for paroxysmal atrial fibrillation.
    Füting A; Reinsch N; Höwel D; Brokkaar L; Rahe G; Neven K
    Europace; 2022 Jul; 24(7):1084-1092. PubMed ID: 35513354
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pulsed Field Ablation Using a Lattice Electrode for Focal Energy Delivery: Biophysical Characterization, Lesion Durability, and Safety Evaluation.
    Yavin H; Shapira-Daniels A; Barkagan M; Sroubek J; Shim D; Melidone R; Anter E
    Circ Arrhythm Electrophysiol; 2020 Jun; 13(6):e008580. PubMed ID: 32372696
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reduction in Pulmonary Vein Stenosis and Collateral Damage With Pulsed Field Ablation Compared With Radiofrequency Ablation in a Canine Model.
    Howard B; Haines DE; Verma A; Packer D; Kirchhof N; Barka N; Onal B; Fraasch S; Miklavčič D; Stewart MT
    Circ Arrhythm Electrophysiol; 2020 Sep; 13(9):e008337. PubMed ID: 32877256
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Circular Multielectrode Pulsed Field Ablation Catheter Lasso Pulsed Field Ablation: Lesion Characteristics, Durability, and Effect on Neighboring Structures.
    Yavin H; Brem E; Zilberman I; Shapira-Daniels A; Datta K; Govari A; Altmann A; Anic A; Wazni O; Anter E
    Circ Arrhythm Electrophysiol; 2021 Feb; 14(2):e009229. PubMed ID: 33417475
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Feasibility, safety, and durability of porcine atrial ablation using a lattice-tip temperature-controlled radiofrequency ablation catheter.
    Koruth JS; Kuroki K; Iwasawa J; Batul SA; Turagam MK; Dukkipati SR; Reddy VY
    J Cardiovasc Electrophysiol; 2020 Jun; 31(6):1323-1331. PubMed ID: 32250501
    [TBL] [Abstract][Full Text] [Related]  

  • 16. How does the level of pulmonary venous isolation compare between pulsed field ablation and thermal energy ablation (radiofrequency, cryo, or laser)?
    Kawamura I; Neuzil P; Shivamurthy P; Kuroki K; Lam J; Musikantow D; Chu E; Turagam MK; Minami K; Funasako M; Petru J; Choudry S; Miller MA; Langan MN; Whang W; Dukkipati SR; Koruth JS; Reddy VY
    Europace; 2021 Nov; 23(11):1757-1766. PubMed ID: 34151947
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pulsed-field ablation combined with ultrahigh-density mapping in patients undergoing catheter ablation for atrial fibrillation: Practical and electrophysiological considerations.
    Gunawardene MA; Schaeffer BN; Jularic M; Eickholt C; Maurer T; Akbulak RÖ; Flindt M; Anwar O; Pape UF; Maasberg S; Gessler N; Hartmann J; Willems S
    J Cardiovasc Electrophysiol; 2022 Mar; 33(3):345-356. PubMed ID: 34978360
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pulmonary Vein Isolation With Single Pulse Irreversible Electroporation: A First in Human Study in 10 Patients With Atrial Fibrillation.
    Loh P; van Es R; Groen MHA; Neven K; Kassenberg W; Wittkampf FHM; Doevendans PA
    Circ Arrhythm Electrophysiol; 2020 Oct; 13(10):e008192. PubMed ID: 32898450
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Application of a circular-shaped pulsed field ablation catheter with magnetic sensors for pulmonary vein isolation: a multi-centre clinical study report.
    Wang Y; Lai HL; Chen Q; Liu H; Liu QM; Huang WB; Tao Y; Xiong Q; Zhou N; Zhao C; Qiu J; Xu Z; Wang DW
    Europace; 2024 Mar; 26(4):. PubMed ID: 38584395
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ostial dimensional changes after pulmonary vein isolation: Pulsed field ablation vs radiofrequency ablation.
    Kuroki K; Whang W; Eggert C; Lam J; Leavitt J; Kawamura I; Reddy A; Morrow B; Schneider C; Petru J; Turagam MK; Koruth JS; Miller MA; Choudry S; Ellsworth B; Dukkipati SR; Neuzil P; Reddy VY
    Heart Rhythm; 2020 Sep; 17(9):1528-1535. PubMed ID: 32380290
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.