These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
148 related articles for article (PubMed ID: 35523746)
1. Effects of the hemolytic index on the test results of a dry chemistry analyzer and a verification of the hemolytic interference threshold. Yang Q; Huang S; Han R; Lin B; Liu Q; Duan X; Ma Z; Zhang H; Shou H; Zhang S Ann Palliat Med; 2022 Apr; 11(4):1381-1390. PubMed ID: 35523746 [TBL] [Abstract][Full Text] [Related]
2. Influence of hemolysis on clinical chemistry parameters determined with Beckman Coulter tests - detection of clinically significant interference. Perović A; Dolčić M Scand J Clin Lab Invest; 2019 May; 79(3):154-159. PubMed ID: 30767593 [TBL] [Abstract][Full Text] [Related]
3. Determination of hemolysis index thresholds for biochemical tests on Siemens Advia 2400 chemistry analyzer. Du Z; Liu J; Zhang H; Bao B; Zhao R; Jin Y J Clin Lab Anal; 2019 May; 33(4):e22856. PubMed ID: 30779463 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of Sensitive Analytes to Hemolysis Interference on an Automated Chemistry Analyzer. Marakankadavu Parambu M; Bush V J Appl Lab Med; 2024 May; 9(3):558-564. PubMed ID: 38300631 [TBL] [Abstract][Full Text] [Related]
5. Assessing the influence of true hemolysis occurring in patient samples on emergency clinical biochemistry tests results using the VITROS Liu S; Li J; Ning L; Wu D; Wei D Biomed Rep; 2021 Nov; 15(5):91. PubMed ID: 34631046 [TBL] [Abstract][Full Text] [Related]
6. [Hemolysis influence on twenty-two biochemical parameters measurement]. Ali D; Sacchetto E; Dumontet E; Le Carrer D; Orsonneau JL; Delaroche O; Bigot-Corbel E Ann Biol Clin (Paris); 2014; 72(3):297-311. PubMed ID: 24876141 [TBL] [Abstract][Full Text] [Related]
8. Effects of hemolysis interferences on routine biochemistry parameters. Koseoglu M; Hur A; Atay A; Cuhadar S Biochem Med (Zagreb); 2011; 21(1):79-85. PubMed ID: 22141211 [TBL] [Abstract][Full Text] [Related]
9. Hemolysis indexes for biochemical tests and immunoassays on Roche analyzers: determination of allowable interference limits according to different calculation methods. Monneret D; Mestari F; Atlan G; Corlouer C; Ramani Z; Jaffre J; Dever S; Fressart V; Alkouri R; Lamari F; Devilliers C; Imbert-Bismut F; Bonnefont-Rousselot D Scand J Clin Lab Invest; 2015 Apr; 75(2):162-9. PubMed ID: 25608598 [TBL] [Abstract][Full Text] [Related]
10. The degree of acceptability of swine blood values at increasing levels of hemolysis evaluated through visual inspection versus automated quantification. Di Martino G; Stefani AL; Lippi G; Gagliazzo L; McCormick W; Gabai G; Bonfanti L J Vet Diagn Invest; 2015 May; 27(3):306-12. PubMed ID: 26038480 [TBL] [Abstract][Full Text] [Related]
11. Correction of patient results for Beckman Coulter LX-20 assays affected by interference due to hemoglobin, bilirubin or lipids: a practical approach. Vermeer HJ; Steen G; Naus AJ; Goevaerts B; Agricola PT; Schoenmakers CH Clin Chem Lab Med; 2007; 45(1):114-9. PubMed ID: 17243928 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of the interference of hemoglobin, bilirubin, and lipids on Roche Cobas 6000 assays. Ji JZ; Meng QH Clin Chim Acta; 2011 Aug; 412(17-18):1550-3. PubMed ID: 21575617 [TBL] [Abstract][Full Text] [Related]
14. Hemoglobin interference from in vivo hemolysis. Blank DW; Kroll MH; Ruddel ME; Elin RJ Clin Chem; 1985 Sep; 31(9):1566-9. PubMed ID: 4028407 [TBL] [Abstract][Full Text] [Related]
15. Effects of hemolysis on serum chemistry analytes in ratites. Andreasen CB; Andreasen JR; Thomas JS Vet Clin Pathol; 1997; 26(4):165-171. PubMed ID: 12658578 [TBL] [Abstract][Full Text] [Related]
16. Design, validation and performance of aspartate aminotransferase- and lactate dehydrogenase-reporting algorithms for haemolysed specimens including correction within quality specifications. Colak S; Tasdemir O; van der Schaaf M; Opdam F; van den Noort V; van den Broek D; van Rossum HH Ann Clin Biochem; 2024 Jul; 61(4):239-247. PubMed ID: 31495183 [TBL] [Abstract][Full Text] [Related]
17. Validation of hemolysis index thresholds optimizes detection of clinically significant hemolysis. Goyal T; Schmotzer CL Am J Clin Pathol; 2015 Apr; 143(4):579-83. PubMed ID: 25780011 [TBL] [Abstract][Full Text] [Related]
18. Determination of hemolysis cut-offs for biochemical and immunochemical analytes according to their value. Dupuy AM; Bargnoux AS; Kuster N; Cristol JP; Badiou S Clin Chem Lab Med; 2020 Jul; 58(8):1232-1241. PubMed ID: 32267242 [TBL] [Abstract][Full Text] [Related]
19. Characterization and mathematical correction of hemolysis interference in selected Hitachi 717 assays. Jay DW; Provasek D Clin Chem; 1993 Sep; 39(9):1804-10. PubMed ID: 8375051 [TBL] [Abstract][Full Text] [Related]
20. The influence of bilirubin, haemolysis and turbidity on 20 analytical tests performed on automatic analysers. Results of an interlaboratory study. Grafmeyer D; Bondon M; Manchon M; Levillain P Eur J Clin Chem Clin Biochem; 1995 Jan; 33(1):31-52. PubMed ID: 7756439 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]