These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 35551158)

  • 21. Biomechanical analysis of anterior ring fixation of the ramus in type C pelvis fractures.
    McLachlin S; Lesieur M; Stephen D; Kreder H; Whyne C
    Eur J Trauma Emerg Surg; 2018 Apr; 44(2):185-190. PubMed ID: 28391395
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Biomechanical comparative study on external fixators of new configurations in the treatment of Tile C pelvic injury.
    Zhao Y; Ma Y; Wu H; Lian W; Li W; Jiang W
    Sci Rep; 2024 Apr; 14(1):9544. PubMed ID: 38664538
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of stability of two kinds of sacro-iliac screws in the fixation of bilateral sacral fractures in a finite element model.
    Zhao Y; Li J; Wang D; Liu Y; Tan J; Zhang S
    Injury; 2012 Apr; 43(4):490-4. PubMed ID: 22281196
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Internal fixation of S1-S3 iliosacral screws and pubic screw as the best configuration for unstable pelvic fracture with unilateral vertical sacral fracture (AO type C1.3).
    Dilogo IH; Satria O; Fiolin J
    J Orthop Surg (Hong Kong); 2017 Jan; 25(1):2309499017690985. PubMed ID: 28270058
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Analysis of trans-sacral corridors in stabilization of fractures of the pelvic ring.
    Jäckle K; Paulisch M; Blüchel T; Meier MP; Seitz MT; Acharya MR; Lehmann W; Spering C
    J Orthop Res; 2022 May; 40(5):1194-1202. PubMed ID: 34292624
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The incidence of and factors affecting iliosacral screw loosening in pelvic ring injury.
    Kim JW; Oh CW; Oh JK; Kyung HS; Park KH; Yoon SD; Yoon SH
    Arch Orthop Trauma Surg; 2016 Jul; 136(7):921-7. PubMed ID: 27168134
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A biomechanical comparison of ipsilateral and contralateral pedicle screw placement for modified triangular osteosynthesis in unstable pelvic fractures.
    Toogood P; McDonald E; Pekmezci M
    J Orthop Trauma; 2013 Sep; 27(9):515-20. PubMed ID: 23187154
    [TBL] [Abstract][Full Text] [Related]  

  • 28. CT-guided sacroiliac percutaneous screw placement in unstable posterior pelvic ring injuries: accuracy of screw position, injury reduction and complications in 71 patients with 136 screws.
    Pieske O; Landersdorfer C; Trumm C; Greiner A; Wallmichrath J; Gottschalk O; Rubenbauer B
    Injury; 2015 Feb; 46(2):333-9. PubMed ID: 25487831
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Incidence of and Risk Factors for Screw Loosening after Iliosacral Screw Fixation for Posterior Pelvic Ring Injury.
    Zhou W; Chen J; Pei X; Liu P; Wang G; Jiang X; Liu X
    Orthop Surg; 2023 Jul; 15(7):1814-1822. PubMed ID: 37345455
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Minimally invasive stabilization of fragility fractures of the pelvis with transsacral bar and retrograde transpubic screw].
    Rommens PM; Wagner D; Arand C; Boudissa M; Hopf J; Hofmann A
    Oper Orthop Traumatol; 2022 Apr; 34(2):153-171. PubMed ID: 35301551
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Vertically unstable pelvic fractures fixed with percutaneous iliosacral screws: does posterior injury pattern predict fixation failure?
    Griffin DR; Starr AJ; Reinert CM; Jones AL; Whitlock S
    J Orthop Trauma; 2006 Jan; 20(1 Suppl):S30-6; discussion S36. PubMed ID: 16385205
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Biomechanical study of anterior and posterior pelvic rings using pedicle screw fixation for Tile C1 pelvic fractures: Finite element analysis.
    Song Y; Shao C; Yang X; Lin F
    PLoS One; 2022; 17(8):e0273351. PubMed ID: 36006983
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of two-transsacral-screw fixation versus triangular osteosynthesis for transforaminal sacral fractures.
    Min KS; Zamorano DP; Wahba GM; Garcia I; Bhatia N; Lee TQ
    Orthopedics; 2014 Sep; 37(9):e754-60. PubMed ID: 25350616
    [TBL] [Abstract][Full Text] [Related]  

  • 34. When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical study.
    Mcdonald E; Theologis AA; Horst P; Kandemir U; Pekmezci M
    Eur J Trauma Emerg Surg; 2015 Dec; 41(6):665-71. PubMed ID: 26038006
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Pelvic ring fractures internal fixation: iliosacral screws versus sacroiliac hinge fixation.
    Ilharreborde B; Breitel D; Lenoir T; Mosnier T; Skalli W; Guigui P; Hoffmann E
    Orthop Traumatol Surg Res; 2009 Dec; 95(8):563-7. PubMed ID: 19910275
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Radiographic quantification and analysis of dysmorphic upper sacral osseous anatomy and associated iliosacral screw insertions.
    Conflitti JM; Graves ML; Chip Routt ML
    J Orthop Trauma; 2010 Oct; 24(10):630-6. PubMed ID: 20871251
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Biomechanical evaluation of location and mode of failure in three screw fixations for a comminuted transforaminal sacral fracture model.
    Crist BD; Pfeiffer FM; Khazzam MS; Kueny RA; Della Rocca GJ; Carson WL
    J Orthop Translat; 2019 Jan; 16():102-111. PubMed ID: 30723687
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Open reduction internal fixation versus percutaneous iliosacral screw fixation for unstable posterior pelvic ring disruptions.
    Elzohairy MM; Salama AM
    Orthop Traumatol Surg Res; 2017 Apr; 103(2):223-227. PubMed ID: 28017873
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Does Posterior Fixation of Partially Unstable Open-Book Pelvic Ring Injuries Decrease Symphyseal Plate Failure? A Biomechanical Study.
    Metz RM; Bledsoe JG; Moed BR
    J Orthop Trauma; 2018 Feb; 32 Suppl 1():S18-S24. PubMed ID: 29373447
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Is a Washer a Mandatory Component in Young Trauma Patients with S1-S2 Iliosacral Screw Fixation of Posterior Pelvis Ring Injuries? A Biomechanical Study.
    Berk T; Zderic I; Schwarzenberg P; Pastor T; Halvachizadeh S; Richards G; Gueorguiev B; Pape HC
    Medicina (Kaunas); 2023 Jul; 59(8):. PubMed ID: 37629669
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.