These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 35567358)

  • 21. Trial design for assessing analytical and clinical performance of high-sensitivity cardiac troponin I assays in the United States: The HIGH-US study.
    Christenson RH; Peacock WF; Apple FS; Limkakeng AT; Nowak RM; McCord J; deFilippi CR
    Contemp Clin Trials Commun; 2019 Jun; 14():100337. PubMed ID: 30834354
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Evaluation of analytical performance of a new high-sensitivity immunoassay for cardiac troponin I.
    Masotti S; Prontera C; Musetti V; Storti S; Ndreu R; Zucchelli GC; Passino C; Clerico A
    Clin Chem Lab Med; 2018 Feb; 56(3):492-501. PubMed ID: 28941350
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Reference values of galectin-3 and cardiac troponins derived from a single cohort of healthy blood donors.
    Mueller T; Egger M; Leitner I; Gabriel C; Haltmayer M; Dieplinger B
    Clin Chim Acta; 2016 May; 456():19-23. PubMed ID: 26920637
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Single test rule-out of acute myocardial infarction using the limit of detection of a new high-sensitivity troponin I assay.
    Body R; Morris N; Collinson P
    Clin Biochem; 2020 Apr; 78():4-9. PubMed ID: 32135083
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of analytical and clinical performance of the AFIAS Tn-I plus assay - a new point-of-care.
    Pittie G; Lukas P; Massart M; Cavalier E; Le Goff C
    Acta Cardiol; 2024 May; 79(3):351-357. PubMed ID: 38032250
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Combining High-Sensitivity Cardiac Troponin I and Cardiac Troponin T in the Early Diagnosis of Acute Myocardial Infarction.
    van der Linden N; Wildi K; Twerenbold R; Pickering JW; Than M; Cullen L; Greenslade J; Parsonage W; Nestelberger T; Boeddinghaus J; Badertscher P; Rubini Giménez M; Klinkenberg LJJ; Bekers O; Schöni A; Keller DI; Sabti Z; Puelacher C; Cupa J; Schumacher L; Kozhuharov N; Grimm K; Shrestha S; Flores D; Freese M; Stelzig C; Strebel I; Miró Ò; Rentsch K; Morawiec B; Kawecki D; Kloos W; Lohrmann J; Richards AM; Troughton R; Pemberton C; Osswald S; van Dieijen-Visser MP; Mingels AM; Reichlin T; Meex SJR; Mueller C
    Circulation; 2018 Sep; 138(10):989-999. PubMed ID: 29691270
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of a novel high sensitivity cardiac troponin I assay with whole blood.
    Lin YH; Li Y; Su BM; Kang JS; Zhou Z
    Clin Chim Acta; 2020 Sep; 508():273-276. PubMed ID: 32445744
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Sex-Specific 99th Percentile Upper Reference Limits for High Sensitivity Cardiac Troponin Assays Derived Using a Universal Sample Bank.
    Apple FS; Wu AHB; Sandoval Y; Sexter A; Love SA; Myers G; Schulz K; Duh SH; Christenson RH
    Clin Chem; 2020 Mar; 66(3):434-444. PubMed ID: 32109298
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Early kinetic profiles of troponin I and T measured by high-sensitivity assays in patients with myocardial infarction.
    Pickering JW; Young JM; George PM; Pemberton CJ; Watson A; Aldous SJ; Verryt T; Troughton RW; Richards AM; Apple FS; Than MP
    Clin Chim Acta; 2020 Jun; 505():15-25. PubMed ID: 32061575
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Analytical and clinical characterization of a novel high-sensitivity cardiac troponin assay in a United States population.
    Christenson RH; Duh SH; Mullins KE; LeClair MM; Grigorov IL; Peacock WF
    Clin Biochem; 2020 Sep; 83():28-36. PubMed ID: 32485169
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Adding stress biomarkers to high-sensitivity cardiac troponin for rapid non-ST-elevation myocardial infarction rule-out protocols.
    Restan IZ; Sanchez AY; Steiro OT; Lopez-Ayala P; Tjora HL; Langørgen J; Omland T; Boeddinghaus J; Nestelberger T; Koechlin L; Collinson P; Bjørneklett R; Vikenes K; Strand H; Skadberg Ø; Mjelva ØR; Larsen AI; Bonarjee VVS; Mueller C; Aakre KM
    Eur Heart J Acute Cardiovasc Care; 2022 Mar; 11(3):201-212. PubMed ID: 35024819
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Clinical evaluation of Ortho Clinical Diagnostics high-sensitivity cardiac Troponin I assay in patients with symptoms suggestive of acute coronary syndrome.
    Kavsak PA; Mondoux SE; Sherbino J; Ma J; Clayton N; Hill SA; McQueen M; Mehta SR; Griffith LE; Devereaux PJ; Worster A
    Clin Biochem; 2020 Jun; 80():48-51. PubMed ID: 32304695
    [TBL] [Abstract][Full Text] [Related]  

  • 33. High-sensitivity cardiac troponin assays: From improved analytical performance to enhanced risk stratification.
    Kozinski M; Krintus M; Kubica J; Sypniewska G
    Crit Rev Clin Lab Sci; 2017 May; 54(3):143-172. PubMed ID: 28457177
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Analytical evaluation of the novel Mindray high sensitivity cardiac troponin I immunoassay on CL-1200i.
    Lippi G; Pighi L; Paviati E; Demonte D; De Nitto S; Gelati M; Montagnana M; Gandini G; Henry BM; Salvagno GL
    Clin Chem Lab Med; 2024 Jun; 62(7):1433-1437. PubMed ID: 38176023
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Imprecision of high-sensitivity cardiac troponin assays at the female 99th-percentile.
    Kavsak PA; Clark L; Arnoldo S; Lou A; Shea JL; Eintracht S; Lyon AW; Bhayana V; Thorlacius L; Raizman JE; Tsui A; Djiana R; Chen M; Huang Y; Haider A; Booth RA; McCudden C; Yip PM; Beriault D; Blank D; Fung AWS; Taher J; St-Cyr J; Sharif S; Belley-Cote E; Abramson BL; Friedman SM; Cox JL; Sivilotti MLA; Chen-Tournoux A; McLaren J; Mak S; Thiruganasambandamoorthy V; Scheuermeyer F; Humphries KH; Worster A; Ko D; Aakre KM; Mills NL; Jaffe AS
    Clin Biochem; 2024 Mar; 125():110731. PubMed ID: 38360198
    [TBL] [Abstract][Full Text] [Related]  

  • 36. High-sensitivity cardiac troponin I: is ethnicity relevant?
    Kalaria TR; Harris N; Sensi H; Valentine R; Asif U; Sharrod-Cole H; Coley-Grant D; Min SS; Ford C; Gama R
    J Clin Pathol; 2021 Nov; 74(11):709-711. PubMed ID: 33782194
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Is high-sensitivity troponin, alone or in combination with copeptin, sensitive enough for ruling out NSTEMI in very early presenters at admission? A post hoc analysis performed in emergency departments.
    Chenevier-Gobeaux C; Sebbane M; Meune C; Lefebvre S; Dupuy AM; Lefèvre G; Peschanski N; Ray P
    BMJ Open; 2019 Jun; 9(6):e023994. PubMed ID: 31209082
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Troponin level at presentation as a prognostic factor among patients presenting with non-ST-segment elevation myocardial infarction.
    Loutati R; Perel N; Bruoha S; Taha L; Tabi M; Marmor D; Amsalem I; Hitter R; Manassra M; Hamayel K; Karameh H; Tommer Maller ; Steinmetz Y; Karmi M; Shuvy M; Glikson M; Asher E
    Clin Cardiol; 2024 Jan; 47(1):e24166. PubMed ID: 37859573
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Analytical evaluation of a new point of care system for measuring cardiac Troponin I.
    Kemper DW; Semjonow V; de Theije F; Keizer D; van Lippen L; Mair J; Wille B; Christ M; Geier F; Hausfater P; Pariente D; Scharnhorst V; Curvers J; Nieuwenhuis J
    Clin Biochem; 2017 Mar; 50(4-5):174-180. PubMed ID: 27847339
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Initial Concentrations of miR-1 MicroRNA Precursor and High-Sensitivity Troponin in the Diagnosis of Non-ST Myocardial Infarction among Patients with and Those without Chronic Kidney Disease.
    Su T; Shao X; Zhang X; Han Z; Yang C; Li X
    Cardiorenal Med; 2019; 9(5):274-283. PubMed ID: 31234177
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.