These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 35572217)

  • 1. Invasive versus non-invasive hemodynamic monitoring of heart failure patients and their outcomes.
    Kandah F; Dhruva P; Shukla R; Ganji M; Palacio C; Missov E; Ruiz-Morales J
    J Geriatr Cardiol; 2022 Apr; 19(4):315-318. PubMed ID: 35572217
    [No Abstract]   [Full Text] [Related]  

  • 2. Continuous noninvasive hemodynamic monitoring in decompensated heart failure.
    Lima MV; Ochiai ME; Vieira KN; Cardoso JN; Brancalhão EC; Puig R; Barretto AC
    Arq Bras Cardiol; 2012 Sep; 99(3):843-7. PubMed ID: 22836357
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Advances in Hemodynamic Monitoring in Heart Failure Patients.
    Imamura T; Narang N
    Intern Med; 2021 Jan; 60(2):167-171. PubMed ID: 32493853
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Remote Hemodynamic-Guided Therapy of Patients With Recurrent Heart Failure Following Cardiac Resynchronization Therapy.
    Varma N; Bourge RC; Stevenson LW; Costanzo MR; Shavelle D; Adamson PB; Ginn G; Henderson J; Abraham WT;
    J Am Heart Assoc; 2021 Feb; 10(5):e017619. PubMed ID: 33626889
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hemodynamic monitoring in acute heart failure.
    Cotter G; Cotter OM; Kaluski E
    Crit Care Med; 2008 Jan; 36(1 Suppl):S40-3. PubMed ID: 18158476
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Non-invasive hemodynamic monitoring in trauma patients.
    Kuster M; Exadaktylos A; Schnüriger B
    World J Emerg Surg; 2015; 10():11. PubMed ID: 25774210
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interventional Heart Failure and Hemodynamic Monitoring.
    Ahmad U; Lilly SM
    Heart Fail Clin; 2018 Oct; 14(4):625-634. PubMed ID: 30266370
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impedance cardiography versus invasive measurements of stroke volume index in patients with chronic heart failure.
    Kieback AG; Borges AC; Schink T; Baumann G; Laule M
    Int J Cardiol; 2010 Aug; 143(2):211-3. PubMed ID: 19144427
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The utility of novel non-invasive technologies for remote hemodynamic monitoring in chronic heart failure.
    Mabote T; Wong K; Cleland JG
    Expert Rev Cardiovasc Ther; 2014 Aug; 12(8):923-8. PubMed ID: 25026973
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Central hemodynamic responses during serial exercise tests in heart failure patients using implantable hemodynamic monitors.
    Ohlsson A; Steinhaus D; Kjellström B; Ryden L; Bennett T
    Eur J Heart Fail; 2003 Jun; 5(3):253-9. PubMed ID: 12798822
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Noninvasive hemodynamic monitoring in heart failure: utilization of impedance cardiography.
    Yancy C; Abraham WT
    Congest Heart Fail; 2003; 9(5):241-50. PubMed ID: 14564142
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hemodynamic profiles by non-invasive monitoring of cardiac index and vascular tone in acute heart failure patients in the emergency department: External validation and clinical outcomes.
    Harrison NE; Meram S; Li X; White MB; Henry S; Gupta S; Zhu D; Pang P; Levy P
    PLoS One; 2022; 17(3):e0265895. PubMed ID: 35358231
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Invasive and non-invasive determinants of pulmonary hypertension in patients with chronic heart failure.
    Capomolla S; Febo O; Guazzotti G; Gnemmi M; Mortara A; Riccardi G; Caporotondi A; Franchini M; Pinna GD; Maestri R; Cobelli F
    J Heart Lung Transplant; 2000 May; 19(5):426-38. PubMed ID: 10808149
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Invasive Hemodynamic Monitoring in Cardiogenic Shock Is Associated With Lower In-Hospital Mortality.
    Osman M; Syed M; Patel B; Munir MB; Kheiri B; Caccamo M; Sokos G; Balla S; Basir MB; Kapur NK; Mamas MA; Bianco CM
    J Am Heart Assoc; 2021 Sep; 10(18):e021808. PubMed ID: 34514850
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Use of the ClearSight® System for Continuous Noninvasive Hemodynamic Monitoring during Heart Valve Interventions: Review of the Literature and Single-Site Experience.
    Gellert G; Bramlage P
    Heart Surg Forum; 2018 Nov; 21(6):E476-E483. PubMed ID: 30604671
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Wireless Hemodynamic Monitoring in Patients with Heart Failure.
    Lander MM; Aldweib N; Abraham WT
    Curr Heart Fail Rep; 2021 Feb; 18(1):12-22. PubMed ID: 33420917
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improving Perioperative Outcomes Through Minimally Invasive and Non-invasive Hemodynamic Monitoring Techniques.
    Yamada T; Vacas S; Gricourt Y; Cannesson M
    Front Med (Lausanne); 2018; 5():144. PubMed ID: 29868596
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Is there a role for invasive hemodynamic monitoring in acute heart failure management?
    De Backer D
    Curr Heart Fail Rep; 2015 Jun; 12(3):197-204. PubMed ID: 25721355
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of rhBNP after PCI on non-invasive hemodynamic in acute myocardial infarction patients with left heart failure.
    He XM; Chen L; Luo JB; Feng XX; Zhang YB; Chen QJ; Ji XL; Wang TS
    Asian Pac J Trop Med; 2016 Aug; 9(8):791-5. PubMed ID: 27569890
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hemodynamic differences among hypertensive patients with and without heart failure using impedance cardiography.
    Silva Lopes B; Craveiro N; Firmino-Machado J; Ribeiro P; Castelo-Branco M
    Ther Adv Cardiovasc Dis; 2019; 13():1753944719876517. PubMed ID: 31554488
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.