These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
195 related articles for article (PubMed ID: 35580595)
1. A randomised trial evaluating mask ventilation using electrical impedance tomography during anesthetic induction: one-handed technique versus two-handed technique. Gao L; Zhu Y; Pan C; Yin Y; Zhao Z; Yang L; Zhang J Physiol Meas; 2022 Jun; 43(6):. PubMed ID: 35580595 [No Abstract] [Full Text] [Related]
2. Electrical Impedance Tomography as a monitoring tool during weaning from mechanical ventilation: an observational study during the spontaneous breathing trial. Wisse JJ; Goos TG; Jonkman AH; Somhorst P; Reiss IKM; Endeman H; Gommers D Respir Res; 2024 Apr; 25(1):179. PubMed ID: 38664685 [TBL] [Abstract][Full Text] [Related]
3. Assessment of respiratory system compliance with electrical impedance tomography using a positive end-expiratory pressure wave maneuver during pressure support ventilation: a pilot clinical study. Becher TH; Bui S; Zick G; Bläser D; Schädler D; Weiler N; Frerichs I Crit Care; 2014 Dec; 18(6):679. PubMed ID: 25492307 [TBL] [Abstract][Full Text] [Related]
4. Comparison of low and high positive end-expiratory pressure during low tidal volume ventilation in robotic gynaecological surgical patients using electrical impedance tomography: A randomised controlled trial. Chun EH; Baik HJ; Moon HS; Jeong K Eur J Anaesthesiol; 2019 Sep; 36(9):641-648. PubMed ID: 31306184 [TBL] [Abstract][Full Text] [Related]
5. Electrical impedance tomography for predicting failure of spontaneous breathing trials in patients with prolonged weaning. Bickenbach J; Czaplik M; Polier M; Marx G; Marx N; Dreher M Crit Care; 2017 Jul; 21(1):177. PubMed ID: 28697778 [TBL] [Abstract][Full Text] [Related]
6. Electrical impedance tomography: A compass for the safe route to optimal PEEP. Sella N; Pettenuzzo T; Zarantonello F; Andreatta G; De Cassai A; Schiavolin C; Simoni C; Pasin L; Boscolo A; Navalesi P Respir Med; 2021 Oct; 187():106555. PubMed ID: 34352563 [TBL] [Abstract][Full Text] [Related]
7. Regional ventilation redistribution measured by electrical impedance tomography during spontaneous breathing trial with automatic tube compensation. Hsu YL; Tien AJ; Chang MY; Chang HT; Möller K; Frerichs I; Zhao Z Physiol Meas; 2017 Jun; 38(6):1193-1203. PubMed ID: 28294957 [TBL] [Abstract][Full Text] [Related]
8. Electrical impedance tomography for lung ventilation monitoring of the dog. Gloning S; Pieper K; Zoellner M; Meyer-Lindenberg A Tierarztl Prax Ausg K Kleintiere Heimtiere; 2017 Feb; 45(1):15-21. PubMed ID: 28094413 [TBL] [Abstract][Full Text] [Related]
9. Distribution of regional lung function in upright healthy subjects determined by electrical impedance tomography in two chest examination planes. Frerichs I; Vogt B; Deuss K; Hennig V; Schädler D; Händel C Physiol Meas; 2024 Jan; 45(1):. PubMed ID: 38096575 [No Abstract] [Full Text] [Related]
10. Assessment of distribution of ventilation and regional lung compliance by electrical impedance tomography in anaesthetized horses undergoing alveolar recruitment manoeuvres. Ambrisko TD; Schramel J; Hopster K; Kästner S; Moens Y Vet Anaesth Analg; 2017 Mar; 44(2):264-272. PubMed ID: 28237681 [TBL] [Abstract][Full Text] [Related]
11. Tidal recruitment assessed by electrical impedance tomography and computed tomography in a porcine model of lung injury*. Muders T; Luepschen H; Zinserling J; Greschus S; Fimmers R; Guenther U; Buchwald M; Grigutsch D; Leonhardt S; Putensen C; Wrigge H Crit Care Med; 2012 Mar; 40(3):903-11. PubMed ID: 22202705 [TBL] [Abstract][Full Text] [Related]
12. Dorsal recruitment with flow-controlled expiration (FLEX): an experimental study in mechanically ventilated lung-healthy and lung-injured pigs. Borgmann S; Schmidt J; Goebel U; Haberstroh J; Guttmann J; Schumann S Crit Care; 2018 Sep; 22(1):245. PubMed ID: 30268138 [TBL] [Abstract][Full Text] [Related]
13. Influence of different PEEP levels on electrical impedance tomography findings in patients under general anesthesia ventilated in the lateral decubitus position. Šribar A; Merc V; Peršec Z; Peršec J; Milas I; Husedžinović S J Clin Monit Comput; 2020 Apr; 34(2):311-318. PubMed ID: 31062131 [TBL] [Abstract][Full Text] [Related]
14. Bedside assessment of the effects of positive end-expiratory pressure on lung inflation and recruitment by the helium dilution technique and electrical impedance tomography. Mauri T; Eronia N; Turrini C; Battistini M; Grasselli G; Rona R; Volta CA; Bellani G; Pesenti A Intensive Care Med; 2016 Oct; 42(10):1576-1587. PubMed ID: 27518321 [TBL] [Abstract][Full Text] [Related]
15. Heterogeneity of regional inflection points from pressure-volume curves assessed by electrical impedance tomography. Scaramuzzo G; Spadaro S; Waldmann AD; Böhm SH; Ragazzi R; Marangoni E; Alvisi V; Spinelli E; Mauri T; Volta CA Crit Care; 2019 Apr; 23(1):119. PubMed ID: 30992054 [TBL] [Abstract][Full Text] [Related]
16. Assessment of electrical impedance tomography to set optimal positive end-expiratory pressure for veno-venous ECMO-treated severe ARDS patients. Puel F; Crognier L; Soulé C; Vardon-Bounes F; Ruiz S; Seguin T; Fourcade O; Minville V; Conil JM; Georges B J Crit Care; 2020 Dec; 60():38-44. PubMed ID: 32736198 [TBL] [Abstract][Full Text] [Related]
17. A two-handed jaw-thrust technique is superior to the one-handed "EC-clamp" technique for mask ventilation in the apneic unconscious person. Joffe AM; Hetzel S; Liew EC Anesthesiology; 2010 Oct; 113(4):873-9. PubMed ID: 20808210 [TBL] [Abstract][Full Text] [Related]
18. Evaluation of an electrical impedance tomography-based Global Inhomogeneity Index for pulmonary ventilation distribution. Zhao Z; Möller K; Steinmann D; Frerichs I; Guttmann J Intensive Care Med; 2009 Nov; 35(11):1900-6. PubMed ID: 19652949 [TBL] [Abstract][Full Text] [Related]
19. Identification of regional overdistension, recruitment and cyclic alveolar collapse with electrical impedance tomography in an experimental ARDS model. Liu S; Tan L; Möller K; Frerichs I; Yu T; Liu L; Huang Y; Guo F; Xu J; Yang Y; Qiu H; Zhao Z Crit Care; 2016 May; 20(1):119. PubMed ID: 27142073 [TBL] [Abstract][Full Text] [Related]
20. Noninvasive ventilation during spontaneous breathing anesthesia: an observational study using electrical impedance tomography. Bordes J; Goutorbe P; Cungi PJ; Boghossian MC; Kaiser E J Clin Anesth; 2016 Nov; 34():420-6. PubMed ID: 27687426 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]