These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 3558200)

  • 1. Reliability of parameter estimates from models applied to respiratory impedance data.
    Lutchen KR; Jackson AC
    J Appl Physiol (1985); 1987 Feb; 62(2):403-13. PubMed ID: 3558200
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of frequency range and input impedance on airway-tissue separation implied from transfer impedance.
    Lutchen KR; Everett JR; Jackson AC
    J Appl Physiol (1985); 1993 Mar; 74(3):1089-99. PubMed ID: 8482647
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Confidence bounds on respiratory mechanical properties estimated from transfer versus input impedance in humans versus dogs.
    Lutchen KR; Jackson AC
    IEEE Trans Biomed Eng; 1992 Jun; 39(6):644-51. PubMed ID: 1601446
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Interpretation of respiratory input impedance in healthy infants.
    Jackson AC; Neff KM; Dorkin HL; Lutchen KR
    Pediatr Pulmonol; 1996 Dec; 22(6):364-75. PubMed ID: 9016470
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Human respiratory input impedance from 4 to 200 Hz: physiological and modeling considerations.
    Dorkin HL; Lutchen KR; Jackson AC
    J Appl Physiol (1985); 1988 Feb; 64(2):823-31. PubMed ID: 3372439
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Airway resistance and tissue elastance from input or transfer impedance in bronchoconstricted monkeys.
    Black KR; Suki B; Madwed JB; Jackson AC
    J Appl Physiol (1985); 2001 Feb; 90(2):571-8. PubMed ID: 11160055
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Respiratory input and transfer mechanical impedances in patients with chronic obstructive pulmonary disease.
    Ying Y; Peslin R; Duvivier C; Gallina C; Felicio da Silva J
    Eur Respir J; 1990 Nov; 3(10):1186-92. PubMed ID: 2090482
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Branching airway network models for analyzing high-frequency lung input impedance.
    Jackson AC; Suki B; Ucar M; Habib R
    J Appl Physiol (1985); 1993 Jul; 75(1):217-27. PubMed ID: 8376267
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of airway and tissue resistances after antigen and methacholine in nonhuman primates.
    Madwed JB; Jackson AC
    J Appl Physiol (1985); 1997 Nov; 83(5):1690-6. PubMed ID: 9375340
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Density dependence of respiratory input and transfer impedances in humans.
    Rotger M; Peslin R; Duvivier C; Navajas D; Gallina C
    J Appl Physiol (1985); 1988 Aug; 65(2):928-33. PubMed ID: 3170438
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Physiological interpretations based on lumped element models fit to respiratory impedance data: use of forward-inverse modeling.
    Lutchen KR; Costa KD
    IEEE Trans Biomed Eng; 1990 Nov; 37(11):1076-86. PubMed ID: 2276755
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimal frequency range to analyze respiratory transfer impedance with six-element model.
    Tomalak W; Peslin R; Duvivier C; Gallina C
    J Appl Physiol (1985); 1993 Dec; 75(6):2656-64. PubMed ID: 8125886
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transfer impedance of the respiratory system by forced oscillation technique and optoelectronic plethysmography.
    Aliverti A; DellacĂ  RL; Pedotti A
    Ann Biomed Eng; 2001 Jan; 29(1):71-82. PubMed ID: 11219509
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Human respiratory input impedance between 32 and 800 Hz, measured by interrupter technique and forced oscillations.
    Frey U; Suki B; Kraemer R; Jackson AC
    J Appl Physiol (1985); 1997 Mar; 82(3):1018-23. PubMed ID: 9074996
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characterization of pulmonary arterial input impedance with lumped parameter models.
    Grant BJ; Paradowski LJ
    Am J Physiol; 1987 Mar; 252(3 Pt 2):H585-93. PubMed ID: 3826403
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Modeling of respiratory system impedances in dogs.
    Jackson AC; Lutchen KR
    J Appl Physiol (1985); 1987 Feb; 62(2):414-20. PubMed ID: 3558201
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sensitivity analysis of respiratory parameter uncertainties: impact of criterion function form and constraints.
    Lutchen KR
    J Appl Physiol (1985); 1990 Aug; 69(2):766-75. PubMed ID: 2228887
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Inverse modeling of dog airway and respiratory system impedances.
    Jackson AC; Lutchen KR; Dorkin HL
    J Appl Physiol (1985); 1987 Jun; 62(6):2273-82. PubMed ID: 3610923
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use of transfer impedance measurements for clinical assessment of lung mechanics.
    Lutchen KR; Sullivan A; Arbogast FT; Celli BR; Jackson AC
    Am J Respir Crit Care Med; 1998 Feb; 157(2):435-46. PubMed ID: 9476855
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Four and six parameter models of forced random noise respiratory impedance in normals.
    Lorino H; Mariette C; Lorino AM; Harf A
    Eur Respir J; 1989 Oct; 2(9):874-82. PubMed ID: 2806515
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.