These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 35585169)

  • 21. Feasibility of 24-h blood pressure telemonitoring in community pharmacies: the TEMPLAR project.
    Omboni S; Ballatore T; Rizzi F; Tomassini F; Campolo L; Panzeri E
    J Hypertens; 2021 Oct; 39(10):2075-2081. PubMed ID: 34102664
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Accuracy of automated blood pressure measurements in the presence of atrial fibrillation: systematic review and meta-analysis.
    Clark CE; McDonagh STJ; McManus RJ
    J Hum Hypertens; 2019 May; 33(5):352-364. PubMed ID: 30631126
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of 3 Devices for 24-Hour Ambulatory Blood Pressure Monitoring in a Nonclinical Environment Through a Randomized Trial.
    Nwankwo T; Coleman King SM; Ostchega Y; Zhang G; Loustalot F; Gillespie C; Chang TE; Begley EB; George MG; Shimbo D; Schwartz JE; Muntner P; Kronish IM; Hong Y; Merritt R
    Am J Hypertens; 2020 Nov; 33(11):1021-1029. PubMed ID: 32701144
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Automated blood pressure measurement in atrial fibrillation: validation process modification and evaluation of a novel professional device which detects atrial fibrillation and adapts its blood pressure measurement algorithm.
    Stergiou GS; Kyriakoulis KG; Bountzona I; Menti A; Destounis A; Kalogeropoulos P; Kollias A
    J Hypertens; 2021 Apr; 39(4):614-620. PubMed ID: 33060450
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Atrial fibrillation and arterial hypertension.
    Kallistratos MS; Poulimenos LE; Manolis AJ
    Pharmacol Res; 2018 Feb; 128():322-326. PubMed ID: 29055746
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Cross-sectional Association Between Blood Pressure Status and Atrial Fibrillation in an Elderly Chinese Population.
    Chen Y; Huang QF; Sheng CS; Lei L; Xu SK; Zhang W; Shao S; Wang D; Cheng YB; Wang Y; Guo QH; Zhang DY; Li Y; Li Y; Freedman SB; Wang JG
    Am J Hypertens; 2019 Jul; 32(8):777-785. PubMed ID: 31004151
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Screening for Atrial Fibrillation in the Older Population: A Randomized Clinical Trial.
    Gladstone DJ; Wachter R; Schmalstieg-Bahr K; Quinn FR; Hummers E; Ivers N; Marsden T; Thornton A; Djuric A; Suerbaum J; von Grünhagen D; McIntyre WF; Benz AP; Wong JA; Merali F; Henein S; Nichol C; Connolly SJ; Healey JS;
    JAMA Cardiol; 2021 May; 6(5):558-567. PubMed ID: 33625468
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Prediction of atrial fibrillation in patients with hypertension: A comprehensive comparison of office and ambulatory blood pressure measurements.
    Huang PH; Huang CC; Lin SJ; Chen JW
    J Clin Hypertens (Greenwich); 2022 Jul; 24(7):838-847. PubMed ID: 35695288
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Diagnostic accuracy of a new algorithm to detect atrial fibrillation in a home blood pressure monitor.
    Kabutoya T; Imai Y; Hoshide S; Kario K
    J Clin Hypertens (Greenwich); 2017 Nov; 19(11):1143-1147. PubMed ID: 28861938
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of the Microlife blood pressure monitor with the Omron blood pressure monitor for detecting atrial fibrillation.
    Wiesel J; Arbesfeld B; Schechter D
    Am J Cardiol; 2014 Oct; 114(7):1046-8. PubMed ID: 25212546
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The accuracy of SpaceLabs 90207 in blood pressure monitoring in patients with atrial fibrillation.
    Miszkowska-Nagórna E; Neubauer-Geryk J; Wolf J; Wielicka M; Raczak G; Narkiewicz K; Bieniaszewski L
    Blood Press; 2018 Feb; 27(1):3-9. PubMed ID: 28738693
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Accuracy of non-invasive blood pressure measurement in patients with atrial fibrillation.
    Su H; Guo Z
    J Hum Hypertens; 2022 Mar; 36(3):229-234. PubMed ID: 34462543
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Clinical study to investigate the predictive parameters for the onset of atrial fibrillation in patients with essential hypertension.
    Ciaroni S; Cuenoud L; Bloch A
    Am Heart J; 2000 May; 139(5):814-9. PubMed ID: 10783214
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Correlation Between Ambulatory Blood Pressure Monitoring and Office Blood Pressure Measurement in Patients with Hypertension: A Community Study.
    Ram CVS; Dani S; Oomman A; Gupta R; Ramachari KO; Kumar GP; Swaminathan J; Kondati S; Sengupta I
    Am J Med Sci; 2021 Dec; 362(6):546-552. PubMed ID: 34161828
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The usefulness of 24-hour blood pressure monitoring for the patients with atrial fibrillation: based on the variability of blood pressure parameters.
    Tong HY; Fan WG; Su H
    Blood Press Monit; 2020 Feb; 25(1):22-25. PubMed ID: 31714349
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A prospective study on the association between atrial fibrillation and blood pressure in an elderly Chinese population.
    Chen Y; Zhang W; Sheng CS; Huang QF; Cheng YB; Guo QH; Zhang DY; Li Y; Freedman B; Wang JG
    Int J Cardiol; 2023 Feb; 372():113-119. PubMed ID: 36513285
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Circadian pattern of ambulatory blood pressure in hypertensive patients with and without type 2 diabetes.
    Ayala DE; Moyá A; Crespo JJ; Castiñeira C; Domínguez-Sardiña M; Gomara S; Sineiro E; Mojón A; Fontao MJ; Hermida RC;
    Chronobiol Int; 2013 Mar; 30(1-2):99-115. PubMed ID: 23098178
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Association of Blood Pressure Classification Using the 2017 American College of Cardiology/American Heart Association Blood Pressure Guideline With Risk of Heart Failure and Atrial Fibrillation.
    Kaneko H; Yano Y; Itoh H; Morita K; Kiriyama H; Kamon T; Fujiu K; Michihata N; Jo T; Takeda N; Morita H; Node K; Carey RM; Lima JAC; Oparil S; Yasunaga H; Komuro I
    Circulation; 2021 Jun; 143(23):2244-2253. PubMed ID: 33886370
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Diagnostic performance of an automatic blood pressure measurement device, Microlife WatchBP Home A, for atrial fibrillation screening in a real-world primary care setting.
    Chan PH; Wong CK; Pun L; Wong YF; Wong MM; Chu DW; Siu CW
    BMJ Open; 2017 Jun; 7(6):e013685. PubMed ID: 28619766
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Blood pressure measurement in atrial fibrillation: review and meta-analysis of evidence on accuracy and clinical relevance.
    Stergiou GS; Kyriakoulis KG; Stambolliu E; Destounis A; Karpettas N; Kalogeropoulos P; Kollias A
    J Hypertens; 2019 Dec; 37(12):2430-2441. PubMed ID: 31408028
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.