These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
158 related articles for article (PubMed ID: 35594579)
1. Predicting the biomechanical stability of IOLs inside the postcataract capsular bag with a finite element model. Cabeza-Gil I; Calvo B Comput Methods Programs Biomed; 2022 Jun; 221():106868. PubMed ID: 35594579 [TBL] [Abstract][Full Text] [Related]
2. Assessment of intraocular lens/capsular bag biomechanical interactions following cataract surgery in a human in vitro graded culture capsular bag model. Wormstone IM; Damm NB; Kelp M; Eldred JA Exp Eye Res; 2021 Apr; 205():108487. PubMed ID: 33571531 [TBL] [Abstract][Full Text] [Related]
3. Posterior capsulorhexis combined with optic buttonholing: an alternative to standard in-the-bag implantation of sharp-edged intraocular lenses? A critical analysis of 1000 consecutive cases. Menapace R Graefes Arch Clin Exp Ophthalmol; 2008 Jun; 246(6):787-801. PubMed ID: 18425525 [TBL] [Abstract][Full Text] [Related]
4. Experimental study of different intraocular lens designs implanted in the bag after capsulorhexis. Tañá P; Belmonte J J Cataract Refract Surg; 1996 Nov; 22(9):1211-21. PubMed ID: 8972372 [TBL] [Abstract][Full Text] [Related]
5. Influence of design parameters and capsulorhexis on intraocular lens stabilities: A 3D finite element analysis. Wang K; Xia Y; Wang X; Pu Y; Zhao Y; Chang P; Pierscionek BK; Fan Y Comput Biol Med; 2023 Jun; 160():106972. PubMed ID: 37120989 [TBL] [Abstract][Full Text] [Related]
6. Capsular bag stability and posterior capsule opacification of a plate-haptic design microincision cataract surgery intraocular lens: 3-year results of a randomised trial. Hirnschall N; Nishi Y; Crnej A; Koshy J; Gangwani V; Maurino V; Findl O Br J Ophthalmol; 2013 Dec; 97(12):1565-8. PubMed ID: 24064942 [TBL] [Abstract][Full Text] [Related]
7. Geometry of Acrylic, Hydrophobic IOLs and Changes in Haptic-Capsular Bag Relationship According to Compression and Different Well Diameters: A Bench Study Using Computed Tomography. Borkenstein AF; Borkenstein EM Ophthalmol Ther; 2022 Apr; 11(2):711-727. PubMed ID: 35122227 [TBL] [Abstract][Full Text] [Related]
8. Influence of a Capsular Tension Ring on Capsular Bag Behavior of a Plate Haptic Intraocular Lens: An Intraindividual Randomized Trial. Schartmüller D; Röggla V; Schwarzenbacher L; Meyer EL; Abela-Formanek C; Leydolt C; Menapace R Ophthalmology; 2024 Apr; 131(4):445-457. PubMed ID: 37914042 [TBL] [Abstract][Full Text] [Related]
9. An in vitro evaluation of the Anew Zephyr open-bag IOL in the prevention of posterior capsule opacification using a human capsular bag model. Eldred JA; Spalton DJ; Wormstone IM Invest Ophthalmol Vis Sci; 2014 Sep; 55(11):7057-64. PubMed ID: 25237161 [TBL] [Abstract][Full Text] [Related]
10. Capsulorhexis ovaling and capsular bag stretch after rigid and foldable intraocular lens implantation: experimental study in pediatric human eyes. Pandey SK; Werner L; Wilson ME; Izak AM; Apple DJ J Cataract Refract Surg; 2004 Oct; 30(10):2183-91. PubMed ID: 15474834 [TBL] [Abstract][Full Text] [Related]
11. Influence of material and haptic design on the mechanical stability of intraocular lenses by means of finite-element modeling. Remón L; Siedlecki D; Cabeza-Gil I; Calvo B J Biomed Opt; 2018 Mar; 23(3):1-10. PubMed ID: 29508566 [TBL] [Abstract][Full Text] [Related]
12. Effect of number and position of intraocular lens haptics on anterior capsule contraction: a randomized, prospective trial. Choi M; Lazo MZ; Kang M; Lee J; Joo CK BMC Ophthalmol; 2018 Mar; 18(1):78. PubMed ID: 29558909 [TBL] [Abstract][Full Text] [Related]
13. Effect of a capsular tension ring on the shape of the capsular bag and opening and the intraocular lens. Lee DH; Lee HY; Lee KH; Chung KH; Joo CK J Cataract Refract Surg; 2001 Mar; 27(3):452-6. PubMed ID: 11255060 [TBL] [Abstract][Full Text] [Related]
14. [A 3-D capsular bag model for describing biomechanical properties of neu intraocular lenses]. Beck R; Pfeiffer K; Stave J; Guthoff R Ophthalmologe; 2000 Aug; 97(8):546-51. PubMed ID: 10994331 [TBL] [Abstract][Full Text] [Related]
16. Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part II: Choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification. Ram J; Apple DJ; Peng Q; Visessook N; Auffarth GU; Schoderbek RJ; Ready EL Ophthalmology; 1999 May; 106(5):891-900. PubMed ID: 10328386 [TBL] [Abstract][Full Text] [Related]
17. Effect of haptic geometry in C-loop intraocular lenses on optical quality. Cabeza-Gil I; Pérez-Gracia J; Remón L; Calvo B J Mech Behav Biomed Mater; 2021 Feb; 114():104165. PubMed ID: 33153923 [TBL] [Abstract][Full Text] [Related]
18. An Experimental Laboratory Study Using the Miyake-Apple Posterior View Technique to Investigate the Dynamics Between Capsular Bags and Different IOL Models. Zhang L; Schickhardt S; Auffarth GU J Refract Surg; 2022 Oct; 38(10):654-660. PubMed ID: 36214352 [TBL] [Abstract][Full Text] [Related]
19. Mini-haptics to improve capsular fixation of plate-haptic silicone intraocular lenses. Kent DG; Peng Q; Isaacs RT; Whiteside SB; Barker DL; Apple DJ J Cataract Refract Surg; 1998 May; 24(5):666-71. PubMed ID: 9610451 [TBL] [Abstract][Full Text] [Related]
20. Morphologic compatibility or intraocular lens haptics and the lens capsule. Nagamoto T; Eguchi G J Cataract Refract Surg; 1997 Oct; 23(8):1254-9. PubMed ID: 9368173 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]