BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

307 related articles for article (PubMed ID: 35595675)

  • 1. Transcatheter Aortic Valve Replacement With Self-Expanding ACURATE neo2: Postprocedural Hemodynamic and Short-Term Clinical Outcomes.
    Buono A; Gorla R; Ielasi A; Costa G; Cozzi O; Ancona M; Soriano F; De Carlo M; Ferrara E; Giannini F; Massussi M; Fovino LN; Pero G; Bettari L; Acerbi E; Messina A; Sgroi C; Pellicano M; Sun J; Gallo F; Franchina AG; Bruno F; Nerla R; Saccocci M; Villa E; D'Ascenzo F; Conrotto F; Cuccia C; Tarantini G; Fiorina C; Castriota F; Poli A; Petronio AS; Oreglia J; Montorfano M; Regazzoli D; Reimers B; Tamburino C; Tespili M; Bedogni F; Barbanti M; Maffeo D;
    JACC Cardiovasc Interv; 2022 Jun; 15(11):1101-1110. PubMed ID: 35595675
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transcatheter aortic valve replacement with the self-expanding ACURATE Neo2 in patients with horizontal aorta: Insights from the ITAL-neo registry.
    Barki M; Ielasi A; Buono A; Maffeo D; Montonati C; Pellegrini D; Pellicano M; Gorla R; Costa G; Cozzi O; Ancona M; Soriano F; De Carlo M; Ferrara E; Giannini F; Massussi M; Fovino LN; Messina A; Sgroi C; Gallo F; Nerla R; Saccocci M; D'Ascenzo F; Conrotto F; Bettari L; Fiorina C; Castriota F; Poli A; Petronio AS; Oreglia J; Montorfano M; Regazzoli D; Reimers B; Barbanti M; Tamburino C; Bedogni F; Tarantini G; Tespili M
    Int J Cardiol; 2023 Oct; 389():131236. PubMed ID: 37532153
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Haemodynamic performance and clinical outcomes of transcatheter aortic valve replacement with the self-expanding ACURATE neo2.
    Scotti A; Pagnesi M; Kim WK; Schäfer U; Barbanti M; Costa G; Baggio S; Casenghi M; De Marco F; Vanhaverbeke M; Sondergaard L; Wolf A; Schofer J; Ancona MB; Montorfano M; Kornowski R; Assa HV; Toggweiler S; Ielasi A; Hildick-Smith D; Windecker S; Schmidt A; Buono A; Maffeo D; Siqueira D; Giannini F; Adamo M; Massussi M; Wood DA; Sinning JM; Van Der Heyden J; van Ginkel DJ; Van Mieghem N; Veulemans V; Mylotte D; Tzalamouras V; Taramasso M; Estévez-Loureiro R; Colombo A; Mangieri A; Latib A
    EuroIntervention; 2022 Nov; 18(10):804-811. PubMed ID: 35678222
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experience with the ACURATE neo and neo2 transcatheter aortic valves in Spain. The PRECISA (PRospective Evaluation Complementing Investigation with ACURATE devices) registry.
    Tébar D; Carrillo X; García Del Blanco B; Gómez-Hospital JA; Nombela L; Molina E; Galeote G; Vilalta V; Serra-García V; Carol GM; Jiménez-Valero S; Fernandez-Nofrerias E; Calabuig-Goena Á; Jurado-Román A; Sánchez-Recalde Á; Velasco MF; Bosca L; Moreno R
    Catheter Cardiovasc Interv; 2024 May; 103(6):1015-1022. PubMed ID: 38577931
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Early Hemodynamic Outcomes in Self-Expandable Valves: Comparison of ACURATE Neo Versus ACURATE Neo2.
    Miyashita H; Moriyama N; Laine M
    Cardiovasc Revasc Med; 2023 Feb; 47():62-69. PubMed ID: 36114124
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transcatheter Aortic Valve Replacement With Next-Generation Self-Expanding Devices: A Multicenter, Retrospective, Propensity-Matched Comparison of Evolut PRO Versus Acurate neo Transcatheter Heart Valves.
    Pagnesi M; Kim WK; Conradi L; Barbanti M; Stefanini GG; Zeus T; Pilgrim T; Schofer J; Zweiker D; Testa L; Taramasso M; Hildick-Smith D; Abizaid A; Wolf A; Van Mieghem NM; Sedaghat A; Wöhrle J; Khogali S; Van der Heyden JAS; Webb JG; Estévez-Loureiro R; Mylotte D; MacCarthy P; Brugaletta S; Hamm CW; Bhadra OD; Schäfer U; Costa G; Tamburino C; Cannata F; Reimers B; Veulemans V; Asami M; Windecker S; Eitan A; Schmidt A; Bianchi G; Bedogni F; Saccocci M; Maisano F; Alsanjari O; Siqueira D; Jensen CJ; Naber CK; Ziviello F; Sinning JM; Seeger J; Rottbauer W; Brouwer J; Alenezi A; Wood DA; Tzalamouras V; Regueiro A; Colombo A; Latib A
    JACC Cardiovasc Interv; 2019 Mar; 12(5):433-443. PubMed ID: 30846081
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multicenter comparison of transcatheter aortic valve implantation with the self-expanding ACURATE neo2 versus Evolut PRO transcatheter heart valves.
    Rheude T; Pellegrini C; Landt M; Bleiziffer S; Wolf A; Renker M; Neuser J; Dörr O; Allali A; Rudolph TK; Wambach JM; Widder JD; Singh P; Berliner D; Alvarez-Covarrubias HA; Richardt G; Xhepa E; Kim WK; Joner M
    Clin Res Cardiol; 2024 Jan; 113(1):38-47. PubMed ID: 37115228
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of the Acurate Neo Vs Neo2 Transcatheter Heart Valves.
    Kim WK; Eckel C; Renker M; Grothusen C; Tiyerili V; Soetemann D; Choi YH; Hamm CW; Möllmann H; Charitos EI; Blumenstein J
    J Invasive Cardiol; 2022 Nov; 34(11):E804-E810. PubMed ID: 36269158
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Early neo2 Registry: Transcatheter Aortic Valve Implantation With ACURATE
    Rück A; Kim WK; Abdel-Wahab M; Thiele H; Rudolph TK; Wolf A; Wambach JM; De Backer O; Sondergaard L; Hengstenberg C; Laine M; Miyashita H; Bjursten H; Götberg M; Pellegrini C; Toggweiler S; Wykrzykowska JJ; Soliman O; Saleh N; Meduri CU
    J Am Heart Assoc; 2023 Aug; 12(15):e029464. PubMed ID: 37489732
    [TBL] [Abstract][Full Text] [Related]  

  • 10. ACURATE neo2 versus SAPIEN 3 Ultra for transcatheter aortic valve implantation.
    Pellegrini C; Rheude T; Renker M; Wolf A; Wambach JM; Alvarez-Covarrubias HA; Dörr O; Singh P; Charitos E; Xhepa E; Joner M; Kim WK
    EuroIntervention; 2023 Jan; 18(12):987-995. PubMed ID: 36250307
    [TBL] [Abstract][Full Text] [Related]  

  • 11. ACURATE neo2 Versus SAPIEN 3 Ultra Transcatheter Heart Valve in Severe Aortic Valve Calcification: A Propensity-Matched Analysis.
    Eckel C; Kim WK; Sötemann D; Grothusen C; Tiyerili V; Dohmen G; Renker M; Charitos EI; Hamm CW; Choi YH; Elsässer A; Möllmann H; Blumenstein J
    Circ Cardiovasc Interv; 2024 May; 17(5):e013608. PubMed ID: 38529637
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantitative Angiographic Assessment of Aortic Regurgitation After Transcatheter Implantation of the Venus A-valve: Comparison with Other Self-Expanding Valves and Impact of a Learning Curve in a Single Chinese Center.
    Wang R; Kawashima H; Mylotte D; Rosseel L; Gao C; Aben JP; Abdelshafy M; Onuma Y; Yang J; Soliman O; Tao L; Serruys PW
    Glob Heart; 2021; 16(1):54. PubMed ID: 34381675
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Paravalvular Aortic Regurgitation Severity Assessed by Quantitative Aortography: ACURATE
    Rück A; Kim WK; Kawashima H; Abdelshafy M; Elkoumy A; Elzomor H; Wang R; Meduri CU; Verouhis D; Saleh N; Onuma Y; Mylotte D; Serruys PW; Soliman O
    J Clin Med; 2021 Oct; 10(20):. PubMed ID: 34682750
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of transcatheter aortic valve replacement with the ACURATE neo2 versus Evolut PRO/PRO+ devices.
    Baggio S; Pagnesi M; Kim WK; Scotti A; Barbanti M; Costa G; Adamo M; Kornowski R; Vaknin Assa H; Estévez-Loureiro R; Cedeño RA; De Marco F; Casenghi M; Toggweiler S; Veulemans V; Mylotte D; Lunardi M; Regazzoli D; Reimers B; Sondergaard L; Vanhaverbeke M; Nuyens P; Maffeo D; Buono A; Saccocci M; Giannini F; Di Ienno L; Ferlini M; Lanzillo G; Ielasi A; Schofer J; Brinkmann C; Van Der Heyden J; Buysschaert I; Eitan A; Wolf A; Adamaszek MM; Colombo A; Latib A; Mangieri A
    EuroIntervention; 2023 Jan; 18(12):977-986. PubMed ID: 36093795
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The ACURATE neo2 valve system for transcatheter aortic valve implantation: 30-day and 1-year outcomes.
    Möllmann H; Holzhey DM; Hilker M; Toggweiler S; Schäfer U; Treede H; Joner M; Søndergaard L; Christen T; Allocco DJ; Kim WK
    Clin Res Cardiol; 2021 Dec; 110(12):1912-1920. PubMed ID: 34148125
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial.
    Lanz J; Kim WK; Walther T; Burgdorf C; Möllmann H; Linke A; Redwood S; Thilo C; Hilker M; Joner M; Thiele H; Conzelmann L; Conradi L; Kerber S; Schymik G; Prendergast B; Husser O; Stortecky S; Heg D; Jüni P; Windecker S; Pilgrim T;
    Lancet; 2019 Nov; 394(10209):1619-1628. PubMed ID: 31570258
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The ACURATE neo Transcatheter Heart Valve: A Comprehensive Analysis of Predictors of Procedural Outcome.
    Kim WK; Möllmann H; Liebetrau C; Renker M; Rolf A; Simon P; Van Linden A; Arsalan M; Doss M; Hamm CW; Walther T
    JACC Cardiovasc Interv; 2018 Sep; 11(17):1721-1729. PubMed ID: 29803694
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of Self-Expanding Bioprostheses for Transcatheter Aortic Valve Replacement in Patients With Symptomatic Severe Aortic Stenosis: SCOPE 2 Randomized Clinical Trial.
    Tamburino C; Bleiziffer S; Thiele H; Scholtz S; Hildick-Smith D; Cunnington M; Wolf A; Barbanti M; Tchetchè D; Garot P; Pagnotta P; Gilard M; Bedogni F; Van Belle E; Vasa-Nicotera M; Chieffo A; Deutsch O; Kempfert J; Søndergaard L; Butter C; Trillo-Nouche R; Lotfi S; Möllmann H; Joner M; Abdel-Wahab M; Bogaerts K; Hengstenberg C; Capodanno D
    Circulation; 2020 Dec; 142(25):2431-2442. PubMed ID: 33054367
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Short-Term Outcomes of ACURATE neo2.
    Tobe A; Garg S; Möllmann H; Rück A; Kim WK; Buono A; Scotti A; Latib A; Toggweiler S; Mangieri A; Laine M; Meduri CU; Rheude T; Wong I; Pruthvi CR; Tsai TY; Onuma Y; Serruys PW
    Struct Heart; 2024 May; 8(3):100277. PubMed ID: 38799801
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Patient-Specific Implantation Technique to Obtain Neo-Commissural Alignment With Self-Expanding Transcatheter Aortic Valves.
    Bieliauskas G; Wong I; Bajoras V; Wang X; Kofoed KF; De Backer O; Søndergaard L
    JACC Cardiovasc Interv; 2021 Oct; 14(19):2097-2108. PubMed ID: 34538602
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.