These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 35609583)

  • 21. Depth of interaction determination in monolithic scintillator with double side SiPM readout.
    Morrocchi M; Ambrosi G; Bisogni MG; Bosi F; Boretto M; Cerello P; Ionica M; Liu B; Pennazio F; Piliero MA; Pirrone G; Postolache V; Wheadon R; Del Guerra A
    EJNMMI Phys; 2017 Dec; 4(1):11. PubMed ID: 28211032
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Artificial neural networks for positioning of gamma interactions in monolithic PET detectors.
    Decuyper M; Stockhoff M; Vandenberghe S; Van Holen R
    Phys Med Biol; 2021 Mar; 66(7):. PubMed ID: 33662940
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Optimizing timing performance of silicon photomultiplier-based scintillation detectors.
    Yeom JY; Vinke R; Levin CS
    Phys Med Biol; 2013 Feb; 58(4):1207-20. PubMed ID: 23369872
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Sub-200 ps CRT in monolithic scintillator PET detectors using digital SiPM arrays and maximum likelihood interaction time estimation.
    van Dam HT; Borghi G; Seifert S; Schaart DR
    Phys Med Biol; 2013 May; 58(10):3243-57. PubMed ID: 23611889
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Experimental time resolution limits of modern SiPMs and TOF-PET detectors exploring different scintillators and Cherenkov emission.
    Gundacker S; Martinez Turtos R; Kratochwil N; Pots RH; Paganoni M; Lecoq P; Auffray E
    Phys Med Biol; 2020 Jan; 65(2):025001. PubMed ID: 31851947
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Optical simulation study on the spatial resolution of a thick monolithic PET detector.
    Stockhoff M; Van Holen R; Vandenberghe S
    Phys Med Biol; 2019 Sep; 64(19):195003. PubMed ID: 31416055
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Monolithic LaBr₃:Ce crystals on silicon photomultiplier arrays for time-of-flight positron emission tomography.
    Seifert S; van Dam HT; Huizenga J; Vinke R; Dendooven P; Löhner H; Schaart DR
    Phys Med Biol; 2012 Apr; 57(8):2219-33. PubMed ID: 22455977
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A 32 mm  ×  32 mm  ×  22 mm monolithic LYSO:Ce detector with dual-sided digital photon counter readout for ultrahigh-performance TOF-PET and TOF-PET/MRI.
    Borghi G; Peet BJ; Tabacchini V; Schaart DR
    Phys Med Biol; 2016 Jul; 61(13):4929-49. PubMed ID: 27286232
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Position estimation using neural networks in semi-monolithic PET detectors.
    Freire M; Barrio J; Cucarella N; Valladares C; Gonzalez-Montoro A; de Alfonso C; Benlloch JM; Gonzalez AJ
    Phys Med Biol; 2022 Dec; 67(24):. PubMed ID: 36384047
    [No Abstract]   [Full Text] [Related]  

  • 30. Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET.
    Yeom JY; Vinke R; Levin CS
    Med Phys; 2014 Dec; 41(12):122501. PubMed ID: 25471979
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Resolution estimation in different monolithic PET detectors using neural networks.
    Belov MV; Kozlov VA; Tskhay VS; Zavertyaev MV
    Phys Med; 2023 Feb; 106():102527. PubMed ID: 36610177
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Novel preclinical PET geometrical concept using a monolithic scintillator crystal offering concurrent enhancement in spatial resolution and detection sensitivity: a simulation study.
    Sanaat A; Arabi H; Reza Ay M; Zaidi H
    Phys Med Biol; 2020 Feb; 65(4):045013. PubMed ID: 31855857
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Model of the point spread function of monolithic scintillator PET detectors for perpendicular incidence.
    Maas MC; van der Laan DJ; van Eijk CW; Schaart DR; Beekman FJ; Bruyndonckx P; Lemaître C
    Med Phys; 2010 Apr; 37(4):1904-13. PubMed ID: 20443512
    [TBL] [Abstract][Full Text] [Related]  

  • 34. On light sharing TOF-PET modules with depth of interaction and 157 ps FWHM coincidence time resolution.
    Pizzichemi M; Polesel A; Stringhini G; Gundacker S; Lecoq P; Tavernier S; Paganoni M; Auffray E
    Phys Med Biol; 2019 Aug; 64(15):155008. PubMed ID: 31239430
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A multiplexed TOF and DOI capable PET detector using a binary position sensitive network.
    Bieniosek MF; Cates JW; Levin CS
    Phys Med Biol; 2016 Nov; 61(21):7639-7651. PubMed ID: 27740946
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Optimization of an ultralow-dose high-resolution pediatric PET scanner design based on monolithic scintillators with dual-sided digital SiPM readout: a simulation study.
    Mikhaylova E; Tabacchini V; Borghi G; Mollet P; D'Hoe E; Schaart DR; Vandenberghe S
    Phys Med Biol; 2017 Oct; 62(21):8402-8418. PubMed ID: 28944759
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A depth-of-interaction PET detector using a stair-shaped reflector arrangement and a single-ended scintillation light readout.
    Son JW; Lee MS; Lee JS
    Phys Med Biol; 2017 Jan; 62(2):465-483. PubMed ID: 28000613
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Impact of event positioning algorithm on performance of a whole-body PET scanner using one-to-one coupled detectors.
    Surti S; Karp JS
    Phys Med Biol; 2018 Mar; 63(5):055008. PubMed ID: 29411709
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of event position reconstruction in monolithic crystals that are optically coupled.
    Morrocchi M; Hunter WC; Del Guerra A; Lewellen TK; Kinahan PE; MacDonald LR; Bisogni MG; Miyaoka RS
    Phys Med Biol; 2016 Dec; 61(23):8298-8320. PubMed ID: 27811385
    [TBL] [Abstract][Full Text] [Related]  

  • 40.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.