These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
24. Echoplanar MR imaging of the liver in patients with focal hepatic lesions: quantitative analysis of images made with various pulse sequences. Saini S; Reimer P; Hahn PF; Cohen MS AJR Am J Roentgenol; 1994 Dec; 163(6):1389-93. PubMed ID: 7992735 [TBL] [Abstract][Full Text] [Related]
25. Quantitative characterization of the Achilles tendon in cadaveric specimens: T1 and T2* measurements using ultrashort-TE MRI at 3 T. Filho GH; Du J; Pak BC; Statum S; Znamorowski R; Haghighi P; Bydder G; Chung CB AJR Am J Roentgenol; 2009 Mar; 192(3):W117-24. PubMed ID: 19234239 [TBL] [Abstract][Full Text] [Related]
26. MR imaging of the lungs: value of short TE spin-echo pulse sequences. Mayo JR; MacKay A; Müller NL AJR Am J Roentgenol; 1992 Nov; 159(5):951-6. PubMed ID: 1414805 [TBL] [Abstract][Full Text] [Related]
27. Quantitative magnetic resonance methods for in vivo investigation of the human liver and spleen. Technical aspects and preliminary clinical results. Thomsen C Acta Radiol Suppl; 1996; 401():1-34. PubMed ID: 8604619 [TBL] [Abstract][Full Text] [Related]
28. Undescended testis: value of MR imaging. Fritzsche PJ; Hricak H; Kogan BA; Winkler ML; Tanagho EA Radiology; 1987 Jul; 164(1):169-73. PubMed ID: 2884693 [TBL] [Abstract][Full Text] [Related]
29. MR imaging of the myocardium using nonionic contrast medium: signal-intensity changes in patients with subacute myocardial infarction. Dulce MC; Duerinckx AJ; Hartiala J; Caputo GR; O'Sullivan M; Cheitlin MD; Higgins CB AJR Am J Roentgenol; 1993 May; 160(5):963-70. PubMed ID: 8470611 [TBL] [Abstract][Full Text] [Related]
30. [Low flip-angle spin-echo imaging of the liver. Basic study and its application to hepatic space-occupying lesions]. Yasui K; Sugimura K Nihon Igaku Hoshasen Gakkai Zasshi; 1991 Sep; 51(9):1017-26. PubMed ID: 1658732 [TBL] [Abstract][Full Text] [Related]
31. A method for T1 rho imaging. Sepponen RE; Pohjonen JA; Sipponen JT; Tanttu JI J Comput Assist Tomogr; 1985; 9(6):1007-11. PubMed ID: 4056129 [TBL] [Abstract][Full Text] [Related]
32. Interindividual reproducibility of glutamate quantification using 1.5-T proton magnetic resonance spectroscopy. Jang DP; Lee JM; Lee E; Park S; Kim JJ; Namkoong K; Yoon KJ; Kim IY; Kim SI Magn Reson Med; 2005 Mar; 53(3):708-12. PubMed ID: 15723390 [TBL] [Abstract][Full Text] [Related]
33. The AAPM/RSNA physics tutorial for residents. Contrast mechanisms in spin-echo MR imaging. Plewes DB Radiographics; 1994 Nov; 14(6):1389-404; quiz 1405-6. PubMed ID: 7855348 [TBL] [Abstract][Full Text] [Related]
34. [Optimization of examining sequences in MR tomography using isosignal displays]. Träber VF; Gieseke J; Steudel A; Lackner K Rofo; 1987 Jan; 146(1):94-101. PubMed ID: 3027796 [TBL] [Abstract][Full Text] [Related]
35. Motion artifact reduction with fast spin-echo imaging. Stark DD; Hendrick RE; Hahn PF; Ferrucci JT Radiology; 1987 Jul; 164(1):183-91. PubMed ID: 3588902 [TBL] [Abstract][Full Text] [Related]
36. MR imaging of bone marrow lesions: relative conspicuousness on T1-weighted, fat-suppressed T2-weighted, and STIR images. Mirowitz SA; Apicella P; Reinus WR; Hammerman AM AJR Am J Roentgenol; 1994 Jan; 162(1):215-21. PubMed ID: 8273669 [TBL] [Abstract][Full Text] [Related]
37. Evaluation of relaxation time measurements by magnetic resonance imaging. A phantom study. Kjaer L; Thomsen C; Henriksen O; Ring P; Stubgaard M; Pedersen EJ Acta Radiol; 1987; 28(3):345-51. PubMed ID: 2958044 [TBL] [Abstract][Full Text] [Related]
38. Optimum acquisition times of two spin echoes for MR image synthesis. Lee JN; Riederer SJ Magn Reson Med; 1986 Aug; 3(4):634-8. PubMed ID: 3747824 [TBL] [Abstract][Full Text] [Related]
39. Design of a fused phantom for quantitative evaluation of brain metabolites and enhanced quality assurance testing for magnetic resonance imaging and spectroscopy. Song KH; Kim SY; Lee DW; Jung JY; Lee JH; Baek HM; Choe BY J Neurosci Methods; 2015 Nov; 255():75-84. PubMed ID: 26277420 [TBL] [Abstract][Full Text] [Related]
40. Use of cerebrospinal fluid gating to improve T2-weighted images. Part II. Temporal lobes, basal ganglia, and brain stem. Enzmann DR; Rubin JB; O'Donohue J; Griffin C; Drace J; Wright A Radiology; 1987 Mar; 162(3):768-73. PubMed ID: 3809492 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]