160 related articles for article (PubMed ID: 35618538)
1. Biomechanical evaluation of combined proximal tibial osteotomy for varus knee osteoarthritis implanted novel designed plate system: Finite element analysis.
Zhao G; Li D; Ji W; Luo C
Injury; 2022 Jul; 53(7):2416-2423. PubMed ID: 35618538
[TBL] [Abstract][Full Text] [Related]
2. Combined proximal tibial osteotomy for varus osteoarthritis of the knee: Biomechanical tests and finite-element analyses.
Ji W; Luo C; Zhan S; Zhan Y; Xie X; Zhang B
Knee; 2020 Jun; 27(3):863-870. PubMed ID: 32046900
[TBL] [Abstract][Full Text] [Related]
3. Role of an anatomically contoured plate and metal block for balanced stability between the implant and lateral hinge in open-wedge high-tibial osteotomy.
Jang YW; Lim D; Seo H; Lee MC; Lee OS; Lee YS
Arch Orthop Trauma Surg; 2018 Jul; 138(7):911-920. PubMed ID: 29546620
[TBL] [Abstract][Full Text] [Related]
4. Comparison of theoretical fixation stability of three devices employed in medial opening wedge high tibial osteotomy: a finite element analysis.
Golovakhа ML; Orljanski W; Benedetto KP; Panchenko S; Büchler P; Henle P; Aghayev E
BMC Musculoskelet Disord; 2014 Jul; 15():230. PubMed ID: 25012591
[TBL] [Abstract][Full Text] [Related]
5. Biomechanical effects of screw orientation and plate profile on tibial condylar valgus osteotomy - Finite-element analysis.
Cheng CT; Luo CA; Chen YC
Comput Methods Biomech Biomed Engin; 2020 Sep; 23(12):906-913. PubMed ID: 32478579
[TBL] [Abstract][Full Text] [Related]
6. The influence of the number of holes in the open wedge high tibial osteotomy on knee biomechanics using finite element analysis.
Kang KT; Koh YG; Lee JA; Lee JJ; Kim PS; Kwon SK
Orthop Traumatol Surg Res; 2021 Jun; 107(4):102884. PubMed ID: 33711507
[TBL] [Abstract][Full Text] [Related]
7. Biomechanical evaluation of opening-wedge high tibial osteotomy with composite materials using finite-element analysis.
Koh YG; Son J; Kwon SK; Kim HJ; Kang KT
Knee; 2018 Dec; 25(6):977-987. PubMed ID: 30446348
[TBL] [Abstract][Full Text] [Related]
8. Salvage of severe knee osteoarthritis: efficacy of tibial condylar valgus osteotomy versus open wedge high tibial osteotomy.
Wang X; Shi L; Zhang R; Wang W; Kong L; Zhao H; Xu J; Kang Q
J Orthop Surg Res; 2021 Jul; 16(1):451. PubMed ID: 34261504
[TBL] [Abstract][Full Text] [Related]
9. Superior survivorship and plate-related results of TomoFix compared to Puddu plate fixation for opening-wedge high tibial osteotomy: A systematic review of the literature.
Ahmed AM; Addosooki A; Saleh Sleem A; Said E
Knee; 2023 Jun; 42():1-18. PubMed ID: 36863116
[TBL] [Abstract][Full Text] [Related]
10. Biomechanical evaluation of high tibial osteotomy plate with internal support block using finite element analysis.
Yang JC; Lin KY; Lin HH; Lee OK
PLoS One; 2021; 16(2):e0247412. PubMed ID: 33630875
[TBL] [Abstract][Full Text] [Related]
11. Biomechanical investigation of the type and configuration of screws used in high tibial osteotomy with titanium locking plate and screw fixation.
Chen YN; Chang CW; Li CT; Chen CH; Chung CR; Chang CH; Peng YT
J Orthop Surg Res; 2019 Jan; 14(1):35. PubMed ID: 30691494
[TBL] [Abstract][Full Text] [Related]
12. Fixation method can affect posterior tibial slope in opening-wedge high tibial osteotomy: a retrospective study.
Yazdi HR; Torkaman A; Ebrahimzadeh Babaki A; Soleimani M; Eslami A
J Orthop Surg Res; 2023 Oct; 18(1):780. PubMed ID: 37848897
[TBL] [Abstract][Full Text] [Related]
13. Biplanar Open Wedge High Tibial Osteotomy in the Medial Compartment Osteoarthritis of the Knee Joint: Comparison between the Aescula and TomoFix Plate.
Kyung HS; Lee BJ; Kim JW; Yoon SD
Clin Orthop Surg; 2015 Jun; 7(2):185-90. PubMed ID: 26217464
[TBL] [Abstract][Full Text] [Related]
14. Effects of plate contouring quality on the biomechanical performance of high tibial osteotomy fixation: A parametric finite element study.
Hayatbakhsh Z; Farahmand F
Proc Inst Mech Eng H; 2022 Mar; 236(3):356-366. PubMed ID: 35001727
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical effects of plate area and locking screw on medial open tibial osteotomy.
Luo CA; Lin SC; Hwa SY; Chen CM; Tseng CS
Comput Methods Biomech Biomed Engin; 2015; 18(12):1263-71. PubMed ID: 24617553
[TBL] [Abstract][Full Text] [Related]
16. Design optimization of high tibial osteotomy plates using finite element analysis for improved biomechanical effect.
Koh YG; Lee JA; Lee HY; Chun HJ; Kim HJ; Kang KT
J Orthop Surg Res; 2019 Jul; 14(1):219. PubMed ID: 31311570
[TBL] [Abstract][Full Text] [Related]
17. Finite element analysis of Puddu and Tomofix plate fixation for open wedge high tibial osteotomy.
Raja Izaham RM; Abdul Kadir MR; Abdul Rashid AH; Hossain MG; Kamarul T
Injury; 2012 Jun; 43(6):898-902. PubMed ID: 22204773
[TBL] [Abstract][Full Text] [Related]
18. Placement-induced effects on high tibial osteotomized construct - biomechanical tests and finite-element analyses.
Luo CA; Hwa SY; Lin SC; Chen CM; Tseng CS
BMC Musculoskelet Disord; 2015 Sep; 16():235. PubMed ID: 26337985
[TBL] [Abstract][Full Text] [Related]
19. [High, open wedge tibial osteotomy: finite element analysis of five internal fixation modalities].
Stepanović Z; Zivković M; Vulović S; Aćimović L; Ristić B; Matić A; Grujović Z
Vojnosanit Pregl; 2011 Oct; 68(10):867-71. PubMed ID: 22165753
[TBL] [Abstract][Full Text] [Related]
20. Tibial condylar valgus osteotomy (TCVO) for osteoarthritis of the knee: 5-year clinical and radiological results.
Chiba K; Yonekura A; Miyamoto T; Osaki M; Chiba G
Arch Orthop Trauma Surg; 2017 Mar; 137(3):303-310. PubMed ID: 28132085
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]