These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
134 related articles for article (PubMed ID: 35633165)
1. Shunt Over-drainage, Slit Ventricle Syndrome, Programmable Valves and Anti-Siphon Devices. A Narrative Review of a Multifactorial and Intractable Problem. Panagopoulos D; Stranjalis G; Gavra M; Boviatsis E; Korfias S J Integr Neurosci; 2022 Apr; 21(3):84. PubMed ID: 35633165 [TBL] [Abstract][Full Text] [Related]
2. Gravitational shunt valves in hydrocephalus to challenge the sequelae of over-drainage. Gutowski P; Gölz L; Rot S; Lemcke J; Thomale UW Expert Rev Med Devices; 2020 Nov; 17(11):1155-1168. PubMed ID: 33176494 [TBL] [Abstract][Full Text] [Related]
3. The Role of Antisiphon Devices in the Prevention of Central Ventricular Catheter Obliteration for Hydrocephalus: A 15-Years Institution's Experience Retrospective Analysis. Panagopoulos D; Strantzalis G; Gavra M; Boviatsis E; Korfias S Children (Basel); 2022 Apr; 9(4):. PubMed ID: 35455537 [TBL] [Abstract][Full Text] [Related]
4. Antisiphon device: A review of existing mechanisms and clinical applications to prevent overdrainage in shunted hydrocephalic patients. Huang AP; Kuo LT; Lai DM; Yang SH; Kuo MF Biomed J; 2022 Feb; 45(1):95-108. PubMed ID: 34411787 [TBL] [Abstract][Full Text] [Related]
5. In vitro performance of the fixed and adjustable gravity-assisted unit with and without motion-evidence of motion-induced flow. Kimura T; Schulz M; Shimoji K; Miyajima M; Arai H; Thomale UW Acta Neurochir (Wien); 2016 Oct; 158(10):2011-8. PubMed ID: 27553048 [TBL] [Abstract][Full Text] [Related]
6. Management of Slit Ventricle Syndrome: A Single-Center Case Series of 32 Surgically Treated Patients. Auricchio AM; Bohnen A; Nichelatti M; Cenzato M; Talamonti G World Neurosurg; 2022 Feb; 158():e352-e361. PubMed ID: 34749014 [TBL] [Abstract][Full Text] [Related]
7. Gravitational shunt units may cause under-drainage in bedridden patients. Kaestner S; Kruschat T; Nitzsche N; Deinsberger W Acta Neurochir (Wien); 2009 Mar; 151(3):217-21; discussion 221. PubMed ID: 19238319 [TBL] [Abstract][Full Text] [Related]
9. Revision to an adjustable non-siphon control valve in low pressure hydrocephalus: therapeutic siphoning and a new perspective on NPH: series of 3 cases and review of the literature. Trinh VT; Duckworth EA Clin Neurol Neurosurg; 2013 Feb; 115(2):175-8. PubMed ID: 22770726 [TBL] [Abstract][Full Text] [Related]
10. Ventriculoperitoneal Shunt Drainage Increases With Gravity and Cerebrospinal Fluid Pressure Pulsations: Benchtop Model. Koueik J; Iskandar BJ; Yang Z; Kraemer MR; Armstrong S; Wakim V; Broman AT; Medow J; Luzzio C; Hsu DA Neurosurgery; 2021 Nov; 89(6):1141-1147. PubMed ID: 34528096 [TBL] [Abstract][Full Text] [Related]
11. Shunt-dependent hydrocephalus: management style among members of the American Society of Pediatric Neurosurgeons. Kraemer MR; Sandoval-Garcia C; Bragg T; Iskandar BJ J Neurosurg Pediatr; 2017 Sep; 20(3):216-224. PubMed ID: 28665241 [TBL] [Abstract][Full Text] [Related]
12. An adjustable gravitational valve for initial VP-shunt treatment in hydrocephalic preterm neonates and infants below 1 year of age. Bock HC; von Philipp G; Ludwig HC Childs Nerv Syst; 2021 Nov; 37(11):3497-3507. PubMed ID: 34152450 [TBL] [Abstract][Full Text] [Related]
13. Shunt survival rates by using the adjustable differential pressure valve combined with a gravitational unit (proGAV) in pediatric neurosurgery. Thomale UW; Gebert AF; Haberl H; Schulz M Childs Nerv Syst; 2013 Mar; 29(3):425-31. PubMed ID: 23135777 [TBL] [Abstract][Full Text] [Related]
15. Laboratory testing of hydrocephalus shunts -- conclusion of the U.K. Shunt evaluation programme. Czosnyka Z; Czosnyka M; Richards HK; Pickard JD Acta Neurochir (Wien); 2002 Jun; 144(6):525-38; discussion 538. PubMed ID: 12111485 [TBL] [Abstract][Full Text] [Related]
16. In vitro performance of six combinations of adjustable differential pressure valves and fixed anti-siphon devices with and without vertical motion. Fiss I; Röhrig P; Hore N; von der Brelie C; Bettag C; Freimann FB; Thomale UW; Rohde V; Brandner S Acta Neurochir (Wien); 2020 Oct; 162(10):2421-2430. PubMed ID: 32779025 [TBL] [Abstract][Full Text] [Related]
17. The treatment of infantile hydrocephalus: "differential-pressure" or "flow-control" valves. A pilot study. Jain H; Sgouros S; Walsh AR; Hockley AD Childs Nerv Syst; 2000 Apr; 16(4):242-6. PubMed ID: 10855523 [TBL] [Abstract][Full Text] [Related]
19. Endoscopic third ventriculostomy in the treatment of shunt-related over-drainage: Preliminary experience with a new approach how to render ventricles navigable. Boschert JM; Krauss JK Clin Neurol Neurosurg; 2006 Feb; 108(2):143-9. PubMed ID: 16412835 [TBL] [Abstract][Full Text] [Related]
20. The delta valve: how does its clinical performance compare with two other pressure differential valves without antisiphon control? Davis SE; Levy ML; McComb JG; Sposto R Pediatr Neurosurg; 2000 Aug; 33(2):58-63. PubMed ID: 11070430 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]