These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
201 related articles for article (PubMed ID: 35644448)
21. Joint B Usman M; Kakkar L; Matakos A; Kirkham A; Arridge S; Atkinson D Magn Reson Imaging; 2020 Jan; 65():90-99. PubMed ID: 31655138 [TBL] [Abstract][Full Text] [Related]
22. Reduction of Distortion Artifacts in Brain MRI Using a Field Map-based Correction Technique in Diffusion-weighted Imaging : A Prospective Study. Grauhan NF; Grünebach N; Brockstedt L; Sanner A; Feiweier T; Schöffling V; Brockmann MA; Othman AE Clin Neuroradiol; 2024 Mar; 34(1):85-91. PubMed ID: 37640838 [TBL] [Abstract][Full Text] [Related]
23. Influence of preprocessing, distortion correction and cardiac triggering on the quality of diffusion MR images of spinal cord. Schilling KG; Combes AJE; Ramadass K; Rheault F; Sweeney G; Prock L; Sriram S; Cohen-Adad J; Gore JC; Landman BA; Smith SA; O'Grady KP Magn Reson Imaging; 2024 May; 108():11-21. PubMed ID: 38309376 [TBL] [Abstract][Full Text] [Related]
24. Evaluation of eddy current distortion and field inhomogeneity distortion corrections in MR diffusion imaging using log-demons DIR method. Arsenault T; Yin FF; Chino J; Craciunescu O; Chang JZ Phys Med Biol; 2021 Jan; 66(3):035021. PubMed ID: 33202395 [TBL] [Abstract][Full Text] [Related]
25. Diffeomorphic susceptibility artifact correction of diffusion-weighted magnetic resonance images. Ruthotto L; Kugel H; Olesch J; Fischer B; Modersitzki J; Burger M; Wolters CH Phys Med Biol; 2012 Sep; 57(18):5715-31. PubMed ID: 22941943 [TBL] [Abstract][Full Text] [Related]
26. A variational image-based approach to the correction of susceptibility artifacts in the alignment of diffusion weighted and structural MRI. Tao R; Fletcher PT; Gerber S; Whitaker RT Inf Process Med Imaging; 2009; 21():664-75. PubMed ID: 19694302 [TBL] [Abstract][Full Text] [Related]
27. Unsupervised cycle-consistent network using restricted subspace field map for removing susceptibility artifacts in EPI. Bao Q; Xie W; Otikovs M; Xia L; Xie H; Liu X; Liu K; Zhang Z; Chen F; Zhou X; Liu C Magn Reson Med; 2023 Aug; 90(2):458-472. PubMed ID: 37052369 [TBL] [Abstract][Full Text] [Related]
28. Prospective and retrospective high order eddy current mitigation for diffusion weighted echo planar imaging. Xu D; Maier JK; King KF; Collick BD; Wu G; Peters RD; Hinks RS Magn Reson Med; 2013 Nov; 70(5):1293-305. PubMed ID: 23325564 [TBL] [Abstract][Full Text] [Related]
29. Correction of Artifacts Induced by B Rodríguez-Soto AE; Fang LK; Holland D; Zou J; Park HH; Keenan KE; Bartsch H; Kuperman J; Wallace AM; Hahn M; Ojeda-Fournier H; Dale AM; Rakow-Penner R J Magn Reson Imaging; 2021 May; 53(5):1581-1591. PubMed ID: 33644939 [TBL] [Abstract][Full Text] [Related]
30. Diffusion-sensitized ophthalmic magnetic resonance imaging free of geometric distortion at 3.0 and 7.0 T: a feasibility study in healthy subjects and patients with intraocular masses. Paul K; Graessl A; Rieger J; Lysiak D; Huelnhagen T; Winter L; Heidemann R; Lindner T; Hadlich S; Zimpfer A; Pohlmann A; Endemann B; Krüger PC; Langner S; Stachs O; Niendorf T Invest Radiol; 2015 May; 50(5):309-21. PubMed ID: 25612144 [TBL] [Abstract][Full Text] [Related]
31. Pseudo multishot echo-planar imaging for geometric distortion improvement. Chen H; Dai K; Bao J; Zhong S; Hu C; Liu Y; Zhang Z NMR Biomed; 2023 May; 36(5):e4885. PubMed ID: 36454107 [TBL] [Abstract][Full Text] [Related]
32. Efficacy of distortion correction on diffusion imaging: comparison of FSL eddy and eddy_correct using 30 and 60 directions diffusion encoding. Yamada H; Abe O; Shizukuishi T; Kikuta J; Shinozaki T; Dezawa K; Nagano A; Matsuda M; Haradome H; Imamura Y PLoS One; 2014; 9(11):e112411. PubMed ID: 25405472 [TBL] [Abstract][Full Text] [Related]
33. Joint correction of Nyquist artifact and minuscule motion-induced aliasing artifact in interleaved diffusion weighted EPI data using a composite two-dimensional phase correction procedure. Chang HC; Chen NK Magn Reson Imaging; 2016 Sep; 34(7):974-9. PubMed ID: 27114342 [TBL] [Abstract][Full Text] [Related]