BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

182 related articles for article (PubMed ID: 35655448)

  • 1. Dose Variations Using an X-Ray Cabinet to Establish
    Bucher M; Weiss T; Endesfelder D; Trompier F; Ristic Y; Kunert P; Schlattl H; Giussani A; Oestreicher U
    Front Public Health; 2022; 10():903509. PubMed ID: 35655448
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Radiation field and dose inhomogeneities using an X-ray cabinet in radiation biology research.
    Bucher M; Trinkl S; Endesfelder D; Weiss T; Gomolka M; Pätzold J; Lechel U; Roessler U; de Las Heras Gala H; Moertl S; Giussani A
    Med Phys; 2021 Dec; 48(12):8140-8151. PubMed ID: 34655237
    [TBL] [Abstract][Full Text] [Related]  

  • 3. RENEB Inter-Laboratory Comparison 2021: The Dicentric Chromosome Assay.
    Endesfelder D; Oestreicher U; Bucher M; Beinke C; Siebenwirth C; Ainsbury E; Moquet J; Gruel G; Gregoire E; Martinez JS; Vral A; Baeyens A; Valente M; Montoro A; Terzoudi G; Triantopoulou S; Pantelias A; Monteiro Gil O; Prieto MJ; Domene MM; Zafiropoulos D; Barquinero JF; Pujol-Canadell M; Lumniczky K; Hargitai R; Kis E; Testa A; Patrono C; Sommer S; Hristova R; Kostova N; Atanasova M; Sevriukova O; Domínguez I; Pastor N; Güçlü I; Pajic J; Sabatier L; Brochard P; Tichy A; Milanova M; Finot F; Cuceu Petrenci C; Wilkins RC; Beaton-Green LA; Seong KM; Lee Y; Lee YH; Balajee AS; Maznyk N; Sypko T; Pham ND; Tran TM; Miura T; Suto Y; Akiyamam M; Tsuyama N; Abe Y; Goh VST; Chua CEL; Abend M; Port M
    Radiat Res; 2023 Jun; 199(6):556-570. PubMed ID: 37018160
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV).
    Tedgren AC; Hedman A; Grindborg JE; Carlsson GA
    Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparative dosimetry study of an alanine dosimeter with a PTW PinPoint chamber at ultra-high dose rates of synchrotron radiation.
    Soliman YS; Pellicioli P; Beshir WB; Abdel-Fattah AA; Fahim RA; Krisch M; Bräuer-Krisch E
    Phys Med; 2020 Mar; 71():161-167. PubMed ID: 32163884
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparative validation of biodosimetry and physical dosimetry techniques for possible triage applications in emergency dosimetry.
    Sholom S; McKeever SWS; Escalona MB; Ryan TL; Balajee AS
    J Radiol Prot; 2022 Mar; 42(2):. PubMed ID: 35196651
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of semi-automatic scoring of dicentric chromosomes after simulation of three different irradiation scenarios.
    Romm H; Ainsbury E; Barnard S; Barrios L; Barquinero JF; Beinke C; Deperas M; Gregoire E; Koivistoinen A; Lindholm C; Moquet J; Oestreicher U; Puig R; Rothkamm K; Sommer S; Thierens H; Vandersickel V; Vral A; Wojcik A
    Health Phys; 2014 Jun; 106(6):764-71. PubMed ID: 24776911
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Construction of dose response calibration curves for dicentrics and micronuclei for X radiation in a Serbian population.
    Pajic J; Rakic B; Jovicic D; Milovanovic A
    Mutat Res Genet Toxicol Environ Mutagen; 2014 Oct; 773():23-8. PubMed ID: 25308702
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Internal breast dosimetry in mammography: Experimental methods and Monte Carlo validation with a monoenergetic x-ray beam.
    Fedon C; Caballo M; Longo R; Trianni A; Sechopoulos I
    Med Phys; 2018 Apr; 45(4):1724-1737. PubMed ID: 29405311
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Variations in dose response with x-ray energy of LiF:Mg,Cu,P thermoluminescence dosimeters: implications for clinical dosimetry.
    Duggan L; Hood C; Warren-Forward H; Haque M; Kron T
    Phys Med Biol; 2004 Sep; 49(17):3831-45. PubMed ID: 15470908
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetric Study of Heat-Treated Calcium-Aluminum-Silicon Borate Dosimeter for Diagnostic Radiology Applications.
    Algain I; Arib M; Al-Said SAF; Donya H
    Sensors (Basel); 2023 Jan; 23(2):. PubMed ID: 36679808
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biological Dosimetry Network in Africa: Establishment of a Dose-Response Curve Using Telomere and Centromere Staining.
    Soumboundou M; Nkengurutse I; Dossou J; Colicchio B; Djebou C; Gadji M; Houenon G; Dem A; Dedjan A; Diarra M; Adjibade R; Finot F; Hempel W; Dieterlen A; Jeandidier E; Rodriguez-Lafrasse C; M'kacher R
    Health Phys; 2019 Dec; 117(6):618-624. PubMed ID: 31211757
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electron paramagnetic resonance (EPR) dosimetry using lithium formate in radiotherapy: comparison with thermoluminescence (TL) dosimetry using lithium fluoride rods.
    Vestad TA; Malinen E; Olsen DR; Hole EO; Sagstuen E
    Phys Med Biol; 2004 Oct; 49(20):4701-15. PubMed ID: 15566169
    [TBL] [Abstract][Full Text] [Related]  

  • 14. RENEB Inter-Laboratory Comparison 2021: Inter-Assay Comparison of Eight Dosimetry Assays.
    Port M; Barquinero JF; Endesfelder D; Moquet J; Oestreicher U; Terzoudi G; Trompier F; Vral A; Abe Y; Ainsbury L; Alkebsi L; Amundson SA; Badie C; Baeyens A; Balajee AS; Balázs K; Barnard S; Bassinet C; Beaton-Green LA; Beinke C; Bobyk L; Brochard P; Brzoska K; Bucher M; Ciesielski B; Cuceu C; Discher M; D Oca MC; Domínguez I; Doucha-Senf S; Dumitrescu A; Duy PN; Finot F; Garty G; Ghandhi SA; Gregoire E; Goh VST; Güçlü I; Hadjiiska L; Hargitai R; Hristova R; Ishii K; Kis E; Juniewicz M; Kriehuber R; Lacombe J; Lee Y; Lopez Riego M; Lumniczky K; Mai TT; Maltar-Strmečki N; Marrale M; Martinez JS; Marciniak A; Maznyk N; McKeever SWS; Meher PK; Milanova M; Miura T; Monteiro Gil O; Montoro A; Moreno Domene M; Mrozik A; Nakayama R; O'Brien G; Oskamp D; Ostheim P; Pajic J; Pastor N; Patrono C; Pujol-Canadell M; Prieto Rodriguez MJ; Repin M; Romanyukha A; Rößler U; Sabatier L; Sakai A; Scherthan H; Schüle S; Seong KM; Sevriukova O; Sholom S; Sommer S; Suto Y; Sypko T; Szatmári T; Takahashi-Sugai M; Takebayashi K; Testa A; Testard I; Tichy A; Triantopoulou S; Tsuyama N; Unverricht-Yeboah M; Valente M; Van Hoey O; Wilkins RC; Wojcik A; Wojewodzka M; Younghyun L; Zafiropoulos D; Abend M
    Radiat Res; 2023 Jun; 199(6):535-555. PubMed ID: 37310880
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Establishment of
    Vijayalakshmi J; Chaurasia RK; Srinivas KS; Vijayalakshmi K; Paul SFD; Bhat NN; Sapra BK
    Heliyon; 2023 Jun; 9(6):e17068. PubMed ID: 37484390
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Commissioning and Assessment of Radiation Field and Dose Inhomogeneity for a Dual X-ray Tube Cabinet Irradiator: To Ensure Accurate Dosimetry in Radiation Biology Experiments.
    Polizzi M; Valerie K; Kim S
    Adv Radiat Oncol; 2024 Jun; 9(6):101486. PubMed ID: 38699670
    [TBL] [Abstract][Full Text] [Related]  

  • 17. CONSTRUCTION AND VALIDATION OF IN VITRO DOSE-RESPONSE CALIBRATION CURVE USING DICENTRIC CHROMOSOME ABERRATION.
    Mirrezaei E; Setayeshi S; Zakeri F; Baradaran S
    Radiat Prot Dosimetry; 2020 Jul; 189(2):198-204. PubMed ID: 32195553
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dosimetric challenges of small animal irradiation with a commercial X-ray unit.
    Kuess P; Bozsaky E; Hopfgartner J; Seifritz G; Dörr W; Georg D
    Z Med Phys; 2014 Dec; 24(4):363-72. PubMed ID: 25270978
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of Dose-Response Calibration Curve for Dicentric Chromosome Induced by X-Rays.
    Lusiyanti Y; Syaifudin M; Budiantari T; Purnami S; Ramadhani D
    Genome Integr; 2019; 10():2. PubMed ID: 31391915
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Establishment and validation of a calibration curve for dicentric chromosome induced by 6MV X-ray.
    Kosarnia M; Bahreyni-Toossi MT; Gholamhosseinian H; Dolat E; Fakour-Mollaee P; Azimian H
    Radiat Prot Dosimetry; 2023 Aug; 199(13):1410-1415. PubMed ID: 37448196
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.