These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 3565688)

  • 1. Salvage of upper arm access grafts by extension to the infraclavicular axillary vein.
    Dubner S; Weinbaum FI
    Am J Surg; 1987 Apr; 153(4):407-8. PubMed ID: 3565688
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Arteriovenous graft with outflow in the proximal axillary vein.
    Teruya TH; Schaeffer D; Abou-Zamzam AM; Bianchi C
    Ann Vasc Surg; 2009; 23(1):95-8. PubMed ID: 18809289
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Arteriovenous Hybrid Graft with Outflow in the Proximal Axillary Vein.
    Murga AG; Chiriano J; Kiang SC; Patel S; Bianchi C; Abou-Zamzam AM; Teruya TH
    Ann Vasc Surg; 2017 Jul; 42():39-44. PubMed ID: 28344184
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prosthetic axillary-axillary arteriovenous straight access (necklace graft) for difficult hemodialysis patients: a prospective single-center experience.
    Morsy MA; Khan A; Chemla ES
    J Vasc Surg; 2008 Nov; 48(5):1251-4, 1254.e1. PubMed ID: 18771891
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Axillary grafts for difficult hemodialysis access.
    McCann RL
    J Vasc Surg; 1996 Sep; 24(3):457-61; discussion 461-2. PubMed ID: 8808968
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Single-center results of a series of prosthetic axillary-axillary arteriovenous access grafts for hemodialysis.
    Gale-Grant O; Chemla ES
    J Vasc Surg; 2016 Dec; 64(6):1741-1746. PubMed ID: 27707619
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prosthetic axillary-axillary arm loop arteriovenous graft for hemodialysis.
    Elwakeel H; Khafagy T; Regal S; Saad E
    Int Angiol; 2013 Dec; 32(6):589-92. PubMed ID: 24212292
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Upper arm graft fistula for hemodialysis.
    Steed DL; McAuley CE; Rault R; Webster MW
    J Vasc Surg; 1984 Sep; 1(5):660-3. PubMed ID: 6502838
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cross-over bypass to axillary vein in haemodialysis patients.
    Jain KM; Simoni EJ
    Eur J Vasc Surg; 1992 Jan; 6(1):101-3. PubMed ID: 1555662
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Outcomes of a Polytetrafluoroethylene Hybrid Vascular Graft with Preloaded Nitinol Stent at the Venous Outflow for Dialysis Vascular Access.
    Habibollahi P; Mantell MP; Rosenberry T; Leeser DB; Clark TWI
    Ann Vasc Surg; 2019 Feb; 55():210-215. PubMed ID: 30217711
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Axillary-axillary loop graft for hemodialysis access.
    Mohamed IH; Bagul A; Doughman T; Nicholson ML
    J Vasc Access; 2011; 12(3):262-3. PubMed ID: 21218383
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of a temporary shunt to preserve the patency of a hemodialysis graft while performing ipsilateral axillo-femoral bypass.
    Argyriou C; Schoretsanitis N; Kantartzi K; Panagoutsos S; Souftas VD; Lazarides MK; Georgiadis GS
    J Vasc Access; 2019 Sep; 20(5):553-556. PubMed ID: 30618343
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparative study of use of Diastat versus standard wall PTFE grafts in upper arm hemodialysis access.
    Almonacid PJ; Pallares EC; Rodriguez AQ; Valdes JS; Rueda Orgaz JA; Polo JR
    Ann Vasc Surg; 2000 Nov; 14(6):659-62. PubMed ID: 11128463
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Early outcomes of the intraluminal flow guard device for secondary renal access.
    Mistry H; Stephenson MA; Valenti D
    J Vasc Access; 2013; 14(2):131-4. PubMed ID: 23172173
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hemodialysis access in the pediatric patient population.
    Lumsden AB; MacDonald MJ; Allen RC; Dodson TF
    Am J Surg; 1994 Aug; 168(2):197-201. PubMed ID: 8053526
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The axillary artery to axillary vein bovine graft for circulatory access: surgical considerations.
    Garcia-Rinaldi R; VonKoch L
    Am J Surg; 1978 Feb; 135(2):265-8. PubMed ID: 626308
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Equivalent secondary patency rates of upper extremity Vectra Vascular Access Grafts and transposed brachial-basilic fistulas with aggressive access surveillance and endovascular treatment.
    Kakkos SK; Andrzejewski T; Haddad JA; Haddad GK; Reddy DJ; Nypaver TJ; Scully MM; Schmid DL
    J Vasc Surg; 2008 Feb; 47(2):407-14. PubMed ID: 18155874
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Durability of early prosthetic dialysis graft cannulation: results of a prospective, nonrandomized clinical trial.
    Hakaim AG; Scott TE
    J Vasc Surg; 1997 Jun; 25(6):1002-5; discussion 1005-6. PubMed ID: 9201160
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The synthetic axillofemoral graft for hemodialysis access.
    Rueckmann I; Berry C; Ouriel K; Hoffart N
    ANNA J; 1991 Dec; 18(6):567-71. PubMed ID: 1750788
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hemodialysis graft for the "hostile" arm.
    Radomski JS
    J Am Coll Surg; 2004 Apr; 198(4):676; author reply 676-7. PubMed ID: 15051026
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 9.