BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 356657)

  • 1. [Reaction of ocular tissues to scleral-implant and encircling material: polyamide--silicone--polyester (author's transl)].
    Witschel H; Faulborn J
    Albrecht Von Graefes Arch Klin Exp Ophthalmol; 1978 Jun; 206(4):217-26. PubMed ID: 356657
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Fragmentation of hydrogel episcleral implants: a series of 4 cases].
    D'hermies F; Korobelnik J; Bertin S; Chauvaud D; Renard G; Audouin J; Diebold J; Duprez A
    J Fr Ophtalmol; 2000 Feb; 23(2):174-9. PubMed ID: 10705120
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Histologic analysis of bioabsorbable scleral buckling implants: an experimental study on rabbits.
    Länsman S; Pääkkö P; Ryhänen J; Hirvelä H; Kellomäki M; Ellä V; Törmälä P; Waris T; Ashammakhi NA
    Retina; 2005 Dec; 25(8):1032-8. PubMed ID: 16340534
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [A roll of silicone sponge as an encircling element in the treatment of retinal detachment].
    Szymański A; Gierek-Lapińska A; Wesołowski T; Zielińska E
    Klin Oczna; 1989; 91(10-12):234-6. PubMed ID: 2700764
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Persistence of indentation with bioabsorbable poly-L/D-lactide versus silicone sponge scleral buckling implants.
    Länsman SM; Karttunen AI; Hirvelä HK; Palosaari JT; Kellomäki M; Ellä V; Ohtonen PP; Törmälä P; Waris TH; Ashammakhi NA
    Retina; 2005; 25(5):581-6. PubMed ID: 16077354
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effects of scleral buckling on young rabbit eyes.
    Moshfeghi AA; Pendergast SD; Hartzer MK; Ferrone PJ
    Arch Ophthalmol; 2004 Apr; 122(4):473-6. PubMed ID: 15078663
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Histological changes related to scleral buckling for treatment of retinal detachment].
    D'Hermies F; Korobelnik JF; Meyer A; Morel X; Béhar-Cohen F; Bertin S; Chérif N; Chauvaud D; Renard G; Audouin J; Diebold J; Duprez A
    Clin Exp Pathol; 1999; 47(5):215-22. PubMed ID: 10598369
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The removal of scleral buckles.
    Hilton GF; Wallyn RH
    Arch Ophthalmol; 1978 Nov; 96(11):2061-3. PubMed ID: 363106
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Efficacy and safety of biodegradable collagen-glycosaminoglycan polymer as a material for scleral buckling.
    Wu WC; Lai CC; Chen HS; Sun MH; Lee LM; Shih CP; Lee HW; Hsu WC
    Invest Ophthalmol Vis Sci; 2008 Jun; 49(6):2673-8. PubMed ID: 18316708
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Injection and impregnation of liquid silicone into ocular tissues.
    Blodi FC
    Am J Ophthalmol; 1971 May; 71(5):1044-51. PubMed ID: 5562510
    [No Abstract]   [Full Text] [Related]  

  • 11. [Resorbable implant materials in retinal detachment surgery. Initial animal experiment studies].
    Guthoff R; Wagner T; Holste J; Winter R
    Klin Monbl Augenheilkd; 1993 Jan; 202(1):43-8. PubMed ID: 8464204
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Limits of constriction in the treatment of retinal detachment.
    Lincoff H; Kreissig I; Parver L
    Arch Ophthalmol; 1976 Sep; 94(9):1473-7. PubMed ID: 962657
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Scleral and episcleral histological changes related to encircling explants in 20 eyes.
    D'Hermies F; Korobelnik JF; Chauvaud D; Pouliquen Y; Parel JM; Renard G
    Acta Ophthalmol Scand; 1999 Jun; 77(3):279-85. PubMed ID: 10406146
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Expanded polytetrafluoroethylene episcleral implants used as encircling scleral buckling. an experimental and histopathological study.
    Korobelnik JF; D'Hermies F; Chauvaud D; Legeais JM; Hoang-Xuan T; Renard G
    Ophthalmic Res; 2000; 32(2-3):110-7. PubMed ID: 10754444
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Histopathologic study of the effect of retinal detachment surgery on 49 eyes obtained post mortem.
    Wilson DJ; Green WR
    Am J Ophthalmol; 1987 Feb; 103(2):167-79. PubMed ID: 3492917
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Implants in retinal detachment surgery (author's transl)].
    Freyler H; Scheimbauer I
    Klin Monbl Augenheilkd; 1980 Sep; 177(3):336-44. PubMed ID: 7453069
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Changes of refraction following operations with episcleral plugs and encircling procedures in cases of retinal detachment (author's transl)].
    Klemen UM
    Klin Monbl Augenheilkd; 1979 Jan; 174(1):109-12. PubMed ID: 431011
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Results following thirty-two scleral buckling operations with encircling polyethylene tube.
    HAMILTON RS
    Surv Ophthalmol; 1962 Aug; 7():249-63. PubMed ID: 13904118
    [No Abstract]   [Full Text] [Related]  

  • 19. [Ciliochoroidal detachment following scleral buckling surgery for rhegmatogenous retinal detachment].
    Kawahara S; Nagai Y; Kawakami E; Yamanaka R; Ida N; Takeuchi M; Uyama M
    Nippon Ganka Gakkai Zasshi; 2000 May; 104(5):344-8. PubMed ID: 10835889
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Silicone encircling bands for retinal detachment: CT appearance.
    Bressler EL; Weinberg PE; Zaret CR
    J Comput Assist Tomogr; 1984 Oct; 8(5):960-2. PubMed ID: 6470266
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.