These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 35671669)

  • 21. Micro Finite Element models of the vertebral body: Validation of local displacement predictions.
    Costa MC; Tozzi G; Cristofolini L; Danesi V; Viceconti M; Dall'Ara E
    PLoS One; 2017; 12(7):e0180151. PubMed ID: 28700618
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A novel mechanical parameter to quantify the microarchitecture effect on apparent modulus of trabecular bone: A computational analysis of ineffective bone mass.
    Jin Y; Zhang T; Cheung JPY; Wong TM; Feng X; Sun T; Zu H; Sze KY; Lu WW
    Bone; 2020 Jun; 135():115314. PubMed ID: 32156663
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Relationship between sample volumes and modulus of human vertebral trabecular bone in micro-finite element analysis.
    Wen XX; Xu C; Zong CL; Feng YF; Ma XY; Wang FQ; Yan YB; Lei W
    J Mech Behav Biomed Mater; 2016 Jul; 60():468-475. PubMed ID: 26999702
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Local strain and damage mapping in single trabeculae during three-point bending tests.
    Jungmann R; Szabo ME; Schitter G; Tang RY; Vashishth D; Hansma PK; Thurner PJ
    J Mech Behav Biomed Mater; 2011 May; 4(4):523-34. PubMed ID: 21396601
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of damage to trabecular bone of the osteoporotic human acetabulum at small strains using nonlinear micro-finite element analyses.
    Ding H; Zhu ZA; Dai KR
    Chin Med J (Engl); 2009 Sep; 122(17):2041-7. PubMed ID: 19781393
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The structural and biomechanical basis of the gain and loss of bone strength in women and men.
    Seeman E
    Endocrinol Metab Clin North Am; 2003 Mar; 32(1):25-38. PubMed ID: 12699291
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Finite element prediction with experimental validation of damage distribution in single trabeculae during three-point bending tests.
    Ridha H; Thurner PJ
    J Mech Behav Biomed Mater; 2013 Nov; 27():94-106. PubMed ID: 23890577
    [TBL] [Abstract][Full Text] [Related]  

  • 28. HR-pQCT-based homogenised finite element models provide quantitative predictions of experimental vertebral body stiffness and strength with the same accuracy as μFE models.
    Pahr DH; Dall'Ara E; Varga P; Zysset PK
    Comput Methods Biomech Biomed Engin; 2012; 15(7):711-20. PubMed ID: 21480081
    [TBL] [Abstract][Full Text] [Related]  

  • 29. High-resolution peripheral quantitative computed tomography (HR-pQCT) can assess microstructural and biomechanical properties of both human distal radius and tibia: Ex vivo computational and experimental validations.
    Zhou B; Wang J; Yu YE; Zhang Z; Nawathe S; Nishiyama KK; Rosete FR; Keaveny TM; Shane E; Guo XE
    Bone; 2016 May; 86():58-67. PubMed ID: 26924718
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Apparent- and Tissue-Level Yield Behaviors of L4 Vertebral Trabecular Bone and Their Associations with Microarchitectures.
    Gong H; Wang L; Fan Y; Zhang M; Qin L
    Ann Biomed Eng; 2016 Apr; 44(4):1204-23. PubMed ID: 26104807
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The importance of intrinsic damage properties to bone fragility: a finite element study.
    Hardisty MR; Zauel R; Stover SM; Fyhrie DP
    J Biomech Eng; 2013 Jan; 135(1):011004. PubMed ID: 23363215
    [TBL] [Abstract][Full Text] [Related]  

  • 32. μFEA successfully exhibits higher stresses and strains in microdamaged regions of whole vertebrae.
    Herblum R; Beek M; Whyne CM
    J Orthop Res; 2013 Oct; 31(10):1653-60. PubMed ID: 23737260
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Prediction of insertion torque and stiffness of a dental implant in bovine trabecular bone using explicit micro-finite element analysis.
    Ovesy M; Indermaur M; Zysset PK
    J Mech Behav Biomed Mater; 2019 Oct; 98():301-310. PubMed ID: 31295709
    [TBL] [Abstract][Full Text] [Related]  

  • 34. MicroFE models of porcine vertebrae with induced bone focal lesions: Validation of predicted displacements with digital volume correlation.
    Palanca M; Oliviero S; Dall'Ara E
    J Mech Behav Biomed Mater; 2022 Jan; 125():104872. PubMed ID: 34655942
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Time-resolved in situ synchrotron-microCT: 4D deformation of bone and bone analogues using digital volume correlation.
    Peña Fernández M; Kao AP; Bonithon R; Howells D; Bodey AJ; Wanelik K; Witte F; Johnston R; Arora H; Tozzi G
    Acta Biomater; 2021 Sep; 131():424-439. PubMed ID: 34126266
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Relative roles of microdamage and microfracture in the mechanical behavior of trabecular bone.
    Yeh OC; Keaveny TM
    J Orthop Res; 2001 Nov; 19(6):1001-7. PubMed ID: 11780997
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Experimental DVC validation of heterogeneous micro finite element models applied to subchondral trabecular bone of the humeral head.
    Knowles NK; Kusins J; Columbus MP; Athwal GS; Ferreira LM
    J Orthop Res; 2022 Sep; 40(9):2039-2047. PubMed ID: 34855264
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Spatial resolution and measurement uncertainty of strains in bone and bone-cement interface using digital volume correlation.
    Zhu ML; Zhang QH; Lupton C; Tong J
    J Mech Behav Biomed Mater; 2016 Apr; 57():269-79. PubMed ID: 26741534
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Finite element analysis of trabecular bone microstructure using CT imaging and continuum mechanical modeling.
    Guha I; Zhang X; Rajapakse CS; Chang G; Saha PK
    Med Phys; 2022 Jun; 49(6):3886-3899. PubMed ID: 35319784
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Prediction of failure in cancellous bone using extended finite element method.
    Salem M; Westover L; Adeeb S; Duke K
    Proc Inst Mech Eng H; 2020 Sep; 234(9):988-999. PubMed ID: 32605523
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.