120 related articles for article (PubMed ID: 35672176)
1. Safe Drill Trajectory for Anatomic Repair of Distal Biceps Tendon Through a Single Incision: A Cadaveric Study.
Mwaturura T; Peters MJ; Glaris Z; Goetz TJ
J Hand Surg Am; 2023 Nov; 48(11):1160.e1-1160.e5. PubMed ID: 35672176
[TBL] [Abstract][Full Text] [Related]
2. Distance of the Posterior Interosseous Nerve From the Bicipital (Radial) Tuberosity at Varying Positions of Forearm Rotation: A Magnetic Resonance Imaging Study With Clinical Implications.
Luthringer TA; Bloom DA; Klein DS; Baron SL; Alaia EF; Burke CJ; Meislin RJ
Am J Sports Med; 2021 Apr; 49(5):1152-1159. PubMed ID: 33635730
[TBL] [Abstract][Full Text] [Related]
3. Use of cortical buttons for the fixation of the distal biceps tendon in combination with the double-incision technique-the relationship between the drill trajectory and the proximity to the posterior interosseous nerve: a cadaveric study.
Benninger E; Meier C
J Shoulder Elbow Surg; 2018 Nov; 27(11):2077-2084. PubMed ID: 30121153
[TBL] [Abstract][Full Text] [Related]
4. Avoiding the posterior interosseous nerve during 2-incision distal biceps tendon repair: an anatomic study.
Chan J; Habis AA; Alzaben E; Bicknell RT; Daneshvar P
J Shoulder Elbow Surg; 2023 Oct; 32(10):2152-2160. PubMed ID: 37331500
[TBL] [Abstract][Full Text] [Related]
5. How to Avoid Posterior Interosseous Nerve Injury During Single-Incision Distal Biceps Repair Drilling.
Becker D; Lopez-Marambio FA; Hammer N; Kieser D
Clin Orthop Relat Res; 2019 Feb; 477(2):424-431. PubMed ID: 30444757
[TBL] [Abstract][Full Text] [Related]
6. Proximity of the posterior interosseous nerve during cortical button guidewire placement for distal biceps tendon reattachment.
Thumm N; Hutchinson D; Zhang C; Drago S; Tyser AR
J Hand Surg Am; 2015 Mar; 40(3):534-6. PubMed ID: 25510155
[TBL] [Abstract][Full Text] [Related]
7. The effect of drill trajectory on proximity to the posterior interosseous nerve during cortical button distal biceps repair.
Lo EY; Li CS; Van den Bogaerde JM
Arthroscopy; 2011 Aug; 27(8):1048-54. PubMed ID: 21705171
[TBL] [Abstract][Full Text] [Related]
8. A cadaveric analysis of tunnel position created using flexible versus rigid instrumentation in a single-incision distal biceps tendon repair.
Alsheikh K; Behrends D; Cota A; Martineau PA
Arthroscopy; 2014 May; 30(5):561-7. PubMed ID: 24655835
[TBL] [Abstract][Full Text] [Related]
9. Distal Biceps Repair With Flexible Instrumentation and Risk of Posterior Interosseous Nerve Injury: A Cadaveric Analysis.
Tat J; Hart A; Cota A; Alsheikh K; Behrends D; Martineau PA
Orthop J Sports Med; 2018 Nov; 6(11):2325967118810523. PubMed ID: 30505874
[TBL] [Abstract][Full Text] [Related]
10. Use of a Bicortical Button to Safely Repair the Distal Biceps in a Two-Incision Approach: A Cadaveric Analysis.
Barlow JD; McNeilan RJ; Speeckaert A; Beals CT; Awan HM
J Hand Surg Am; 2017 Jul; 42(7):570.e1-570.e6. PubMed ID: 28434835
[TBL] [Abstract][Full Text] [Related]
11. Risk of Posterior Interosseous Nerve Injury During Distal Biceps Tendon Repair Using a Cortical Button.
Lynch B; Duke A; Komatsu D; Wang E
J Hand Surg Glob Online; 2022 Jan; 4(1):14-18. PubMed ID: 35415600
[TBL] [Abstract][Full Text] [Related]
12. The effect of drilling angle on posterior interosseous nerve safety during open and endoscopic anterior single-incision repair of the distal biceps tendon.
Saldua N; Carney J; Dewing C; Thompson M
Arthroscopy; 2008 Mar; 24(3):305-10. PubMed ID: 18308182
[TBL] [Abstract][Full Text] [Related]
13. Double-Incision Technique for the Treatment of Distal Biceps Tendon Rupture.
Mercurio M; Castioni D; Cosentino O; Fanelli D; Familiari F; Gasparini G; Galasso O
JBJS Essent Surg Tech; 2022; 12(3):e21.00033. PubMed ID: 36816526
[TBL] [Abstract][Full Text] [Related]
14. Anatomical evaluation of a cortical button for distal biceps tendon repairs.
Duncan D; Lancaster G; Marsh SG; Michaelson JE; Lemos SE
Hand (N Y); 2013 Jun; 8(2):201-4. PubMed ID: 24426919
[TBL] [Abstract][Full Text] [Related]
15. Optimization of Anterior Incision Placement for Distal Biceps Repair.
Klebanov N; Wei DH; Harrison BJ; Kimball HL
Cureus; 2018 Aug; 10(8):e3141. PubMed ID: 30345198
[TBL] [Abstract][Full Text] [Related]
16. Power-Optimizing Repair for Distal Biceps Tendon Rupture: Stronger and Safer.
Tadevich JT; Bhagat ND; Lim BH; Gao J; Chen WW; Merrell GA
J Hand Surg Glob Online; 2021 Sep; 3(5):266-271. PubMed ID: 35415576
[TBL] [Abstract][Full Text] [Related]
17. Distal biceps tendon insertion: an anatomic study.
Hutchinson HL; Gloystein D; Gillespie M
J Shoulder Elbow Surg; 2008; 17(2):342-6. PubMed ID: 17931901
[TBL] [Abstract][Full Text] [Related]
18. Posterior Interosseous Nerve Proximity to Cortical Button Implant for Distal Biceps Repair With Single and 2-Incision Approaches.
Strong BM; Voloshin I
J Hand Surg Am; 2019 Jul; 44(7):613.e1-613.e6. PubMed ID: 30301643
[TBL] [Abstract][Full Text] [Related]
19. Distal Biceps Tendon Anatomic Repair.
Schmidt CC; Styron JF; Lin EA; Brown BT
JBJS Essent Surg Tech; 2017 Dec; 7(4):e32. PubMed ID: 30233967
[TBL] [Abstract][Full Text] [Related]
20. Effect of elbow flexion on the proximity of the PIN during 2-incision distal biceps repair.
Jones JA; Jones CM; Grossman MG
Orthopedics; 2013 Jul; 36(7):e931-5. PubMed ID: 23823052
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]