274 related articles for article (PubMed ID: 35672857)
21. Fully implantable neural recording and stimulation interfaces: Peripheral nerve interface applications.
Deshmukh A; Brown L; Barbe MF; Braverman AS; Tiwari E; Hobson L; Shunmugam S; Armitage O; Hewage E; Ruggieri MR; Morizio J
J Neurosci Methods; 2020 Mar; 333():108562. PubMed ID: 31862376
[TBL] [Abstract][Full Text] [Related]
22. A mm-Sized Free-Floating Wirelessly Powered Implantable Optical Stimulation Device.
Jia Y; Mirbozorgi SA; Lee B; Khan W; Madi F; Inan OT; Weber A; Li W; Ghovanloo M
IEEE Trans Biomed Circuits Syst; 2019 Aug; 13(4):608-618. PubMed ID: 31135371
[TBL] [Abstract][Full Text] [Related]
23. Wireless Torque and Power Transfer Using Multiple Coils with LCC-S Topology for Implantable Medical Drug Pump.
Rhee J; Shin Y; Woo S; Lee C; Kim D; Ahn J; Kim H; Ahn S
Sensors (Basel); 2021 Dec; 21(23):. PubMed ID: 34884150
[TBL] [Abstract][Full Text] [Related]
24. Development of a battery-free ultrasonically powered functional electrical stimulator for movement restoration after paralyzing spinal cord injury.
Alam M; Li S; Ahmed RU; Yam YM; Thakur S; Wang XY; Tang D; Ng S; Zheng YP
J Neuroeng Rehabil; 2019 Mar; 16(1):36. PubMed ID: 30850027
[TBL] [Abstract][Full Text] [Related]
25. An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode.
Shon A; Chu JU; Jung J; Kim H; Youn I
Sensors (Basel); 2017 Dec; 18(1):. PubMed ID: 29267230
[TBL] [Abstract][Full Text] [Related]
26. Rechargeable wireless EMG sensor for prosthetic control.
Lichter PA; Lange EH; Riehle TH; Anderson SM; Hedin DS
Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():5074-6. PubMed ID: 21095801
[TBL] [Abstract][Full Text] [Related]
27. Wearable wireless power systems for 'ME-BIT' magnetoelectric-powered bio implants.
Alrashdan FT; Chen JC; Singer A; Avants BW; Yang K; Robinson JT
J Neural Eng; 2021 Jul; 18(4):. PubMed ID: 34229314
[No Abstract] [Full Text] [Related]
28. Modeling and Characterization of Scaling Factor of Flexible Spiral Coils for Wirelessly Powered Wearable Sensors.
Biswas DK; Sinclair M; Le T; Pullano SA; Fiorillo AS; Mahbub I
Sensors (Basel); 2020 Apr; 20(8):. PubMed ID: 32316392
[TBL] [Abstract][Full Text] [Related]
29. Injectable Sensors Based on Passive Rectification of Volume-Conducted Currents.
Malik S; Castellvi Q; Becerra-Fajardo L; Tudela-Pi M; Garcia-Moreno A; Baghini MS; Ivorra A
IEEE Trans Biomed Circuits Syst; 2020 Aug; 14(4):867-878. PubMed ID: 32746346
[TBL] [Abstract][Full Text] [Related]
30. Induction of Inflammation In Vivo by Electrocardiogram Sensor Operation Using Wireless Power Transmission.
Heo JC; Kim B; Kim YN; Kim DK; Lee JH
Sensors (Basel); 2017 Dec; 17(12):. PubMed ID: 29240666
[TBL] [Abstract][Full Text] [Related]
31. Enabling wireless powering and telemetry for peripheral nerve implants.
Jegadeesan R; Nag S; Agarwal K; Thakor NV; Guo YX
IEEE J Biomed Health Inform; 2015 May; 19(3):958-70. PubMed ID: 25910261
[TBL] [Abstract][Full Text] [Related]
32. Multi-Access Networking with Wireless Ultrasound-Powered Implants.
Chang TC; Wang M; Arbabian A
IEEE Biomed Circuits Syst Conf; 2019 Oct; 2019():. PubMed ID: 31989118
[TBL] [Abstract][Full Text] [Related]
33. LoRaWAN Battery-Free Wireless Sensors Network Designed for Structural Health Monitoring in the Construction Domain.
Loubet G; Takacs A; Gardner E; De Luca A; Udrea F; Dragomirescu D
Sensors (Basel); 2019 Mar; 19(7):. PubMed ID: 30925754
[TBL] [Abstract][Full Text] [Related]
34. Ultracompact Implantable Design With Integrated Wireless Power Transfer and RF Transmission Capabilities.
Sun G; Muneer B; Li Y; Zhu Q
IEEE Trans Biomed Circuits Syst; 2018 Apr; 12(2):281-291. PubMed ID: 29570056
[TBL] [Abstract][Full Text] [Related]
35. Fully Passive Flexible Wireless Neural Recorder for the Acquisition of Neuropotentials from a Rat Model.
Liu S; Moncion C; Zhang J; Balachandar L; Kwaku D; Riera JJ; Volakis JL; Chae J
ACS Sens; 2019 Dec; 4(12):3175-3185. PubMed ID: 31670508
[TBL] [Abstract][Full Text] [Related]
36. Batteryless, Miniaturized Implantable Glucose Sensor Using a Fluorescent Hydrogel.
Lee H; Lee J; Park H; Nam MS; Heo YJ; Kim S
Sensors (Basel); 2021 Dec; 21(24):. PubMed ID: 34960558
[TBL] [Abstract][Full Text] [Related]
37. Implantation and Control of Wireless, Battery-free Systems for Peripheral Nerve Interfacing.
Wang H; D'Andrea D; Choi YS; Bouricha Y; Wickerson G; Ahn HY; Guo H; Huang Y; Sandhu MS; Jordan SW; Rogers JA; Franz CK
J Vis Exp; 2021 Oct; (176):. PubMed ID: 34747395
[TBL] [Abstract][Full Text] [Related]
38. A remotely powered implantable biomedical system with location detector.
Kilinc EG; Ghanad MA; Maloberti F; Dehollain C
IEEE Trans Biomed Circuits Syst; 2015 Feb; 9(1):113-23. PubMed ID: 24988596
[TBL] [Abstract][Full Text] [Related]
39. Implantable multichannel wireless electromyography for prosthesis control.
McDonnall D; Hiatt S; Smith C; Guillory KS
Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():1350-3. PubMed ID: 23366149
[TBL] [Abstract][Full Text] [Related]
40. Optimal Frequency and Wireless Power Budget for Miniature Receivers in Obese People.
Van de Steene T; Tanghe E; Martens L; Garripoli C; Stanzione S; Joseph W
Sensors (Basel); 2023 Sep; 23(19):. PubMed ID: 37836914
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]