These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 35683112)

  • 1. Mechanical Properties and Corrosion Behavior of Thermally Treated Ti-6Al-7Nb Dental Alloy.
    Hulka I; Florido-Suarez NR; Mirza-Rosca JC; Saceleanu A
    Materials (Basel); 2022 May; 15(11):. PubMed ID: 35683112
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative corrosion study of Ti-Ta alloys for dental applications.
    Mareci D; Chelariu R; Gordin DM; Ungureanu G; Gloriant T
    Acta Biomater; 2009 Nov; 5(9):3625-39. PubMed ID: 19508903
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The development of Ti alloys for dental implant with high corrosion resistance and mechanical strength.
    Yamazoe J; Nakagawa M; Matono Y; Takeuchi A; Ishikawa K
    Dent Mater J; 2007 Mar; 26(2):260-7. PubMed ID: 17621943
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mechanical properties and corrosion resistance of Ti-6Al-7Nb alloy dental castings.
    Kobayashi E; Wang TJ; Doi H; Yoneyama T; Hamanaka H
    J Mater Sci Mater Med; 1998 Oct; 9(10):567-74. PubMed ID: 15348689
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Conjoint corrosion and wear in titanium alloys.
    Khan MA; Williams RL; Williams DF
    Biomaterials; 1999 Apr; 20(8):765-72. PubMed ID: 10353659
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of the mechanical properties of powder metallurgy Ti-6Al-7Nb alloy.
    Bolzoni L; Ruiz-Navas EM; Gordo E
    J Mech Behav Biomed Mater; 2017 Mar; 67():110-116. PubMed ID: 27988440
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biocompatibility of new low-cost (α + β)-type Ti-Mo-Fe alloys for long-term implantation.
    Abdelrhman Y; Gepreel MA; Kobayashi S; Okano S; Okamoto T
    Mater Sci Eng C Mater Biol Appl; 2019 Jun; 99():552-562. PubMed ID: 30889729
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The corrosion behaviour of Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr in protein solutions.
    Khan MA; Williams RL; Williams DF
    Biomaterials; 1999 Apr; 20(7):631-7. PubMed ID: 10208405
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ti-30Nb-3Ag alloy with improved corrosion resistance and antibacterial properties for orthopedic and dental applications produced by mechanical alloying.
    Hussein MA; Kumar AM; Azeem MA; Sorour AA; Saravanan S
    J Mech Behav Biomed Mater; 2023 Jun; 142():105851. PubMed ID: 37068434
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Electrochemical corrosion behavior and elasticity properties of Ti-6Al-xFe alloys for biomedical applications.
    Lu J; Zhao Y; Niu H; Zhang Y; Du Y; Zhang W; Huo W
    Mater Sci Eng C Mater Biol Appl; 2016 May; 62():36-44. PubMed ID: 26952395
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Corrosion resistance of a new Ti-12.5Zr-3Nb-2.5Sn alloy].
    Hu X; Wei Q; Li CY; Deng JY; Liu S; Zhang LY
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2010 Sep; 45(9):569-72. PubMed ID: 21122455
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mechanical strength and microstructure of laser-welded Ti-6Al-7Nb alloy castings.
    Srimaneepong V; Yoneyama T; Kobayashi E; Doi H; Hanawa T
    Dent Mater J; 2005 Dec; 24(4):541-9. PubMed ID: 16445016
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Joint prostheses components of warm-forged and surface treated Ti-6Al-7Nb alloy].
    Semlitsch M; Weber H; Streicher RM; Schön R
    Biomed Tech (Berl); 1991 May; 36(5):112-9. PubMed ID: 1859861
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Castability and mechanical properties of Ti-15Mo-5Zr-3Al alloy in dental casting.
    Koizumi H; Ishii T; Okazaki T; Kaketani M; Matsumura H; Yoneyama T
    J Oral Sci; 2018; 60(2):285-292. PubMed ID: 29925713
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments.
    Nakagawa M; Matono Y; Matsuya S; Udoh K; Ishikawa K
    Biomaterials; 2005 May; 26(15):2239-46. PubMed ID: 15585225
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of noble metals alloying additions on the corrosion behaviour of titanium in a fluoride-containing environment.
    Rosalbino F; Delsante S; Borzone G; Scavino G
    J Mater Sci Mater Med; 2012 May; 23(5):1129-37. PubMed ID: 22382735
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Precipitation hardening and microstructure evolution of the Ti-7Nb-10Mo alloy during aging.
    Yi R; Liu H; Yi D; Wan W; Wang B; Jiang Y; Yang Q; Wang D; Gao Q; Xu Y; Tang Q
    Mater Sci Eng C Mater Biol Appl; 2016 Jun; 63():577-86. PubMed ID: 27040253
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Corrosion behavior of pure titanium and titanium alloys in fluoride-containing solutions.
    Nakagawa M; Matsuya S; Udoh K
    Dent Mater J; 2001 Dec; 20(4):305-14. PubMed ID: 11915624
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Influence of Microstructure on the Passive Layer Chemistry and Corrosion Resistance for Some Titanium-Based Alloys.
    El-Bagoury N; Ahmed SI; Ahmed Abu Ali O; El-Hadad S; Fallatah AM; Mersal GAM; Ibrahim MM; Wysocka J; Ryl J; Boukherroub R; A Amin M
    Materials (Basel); 2019 Apr; 12(8):. PubMed ID: 30991704
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Joint replacement components made of hot-forged and surface-treated Ti-6Al-7Nb alloy.
    Semlitsch MF; Weber H; Streicher RM; Schön R
    Biomaterials; 1992; 13(11):781-8. PubMed ID: 1391401
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.