These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 35685567)

  • 1. Prolonged P Wave Peak Time May Be a Sign of LV Diastolic Dysfunction in the Coronary Slow Flow Phenomenon.
    Aslan B; Işık F; Akyüz A; İnci Ü; Karadeniz M
    Int J Clin Pract; 2022; 2022():4626701. PubMed ID: 35685567
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of left and right ventricular diastolic and systolic functions using two-dimensional speckle-tracking echocardiography in patients with coronary slow-flow phenomenon.
    Wang Y; Ma C; Zhang Y; Guan Z; Liu S; Li Y; Yang J
    PLoS One; 2015; 10(2):e0117979. PubMed ID: 25706989
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Association of P wave peak time with left ventricular end-diastolic pressure in patients with hypertension.
    Burak C; Çağdaş M; Rencüzoğulları I; Karabağ Y; Artaç I; Yesin M; Çınar T; Yıldız I; Suleymanoglu M; Tanboğa HI
    J Clin Hypertens (Greenwich); 2019 May; 21(5):608-615. PubMed ID: 30950573
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of coronary slow flow on left atrial structure and function.
    Shui Z; Wang Y; Sun M; Gao Y; Liang S; Wang Y; Wang X; Yu Q; Zhang S; Liu L
    Sci Rep; 2021 Apr; 11(1):7511. PubMed ID: 33820937
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Evaluation of left ventricular systolic and diastolic functions in patients with coronary slow flow phenomenon].
    Zencir C; Cetin M; Güngör H; Karaman K; Akgüllü C; Eryılmaz U; Avcil M
    Turk Kardiyol Dern Ars; 2013 Dec; 41(8):691-6. PubMed ID: 24351942
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Are biventricular systolic functions impaired in patient with coronoray slow flow? A prospective study with three dimensional speckle tracking.
    Kemaloğlu Öz T; Eren M; Atasoy I; Gürol T; Soylu Ö; Dağdeviren B
    Int J Cardiovasc Imaging; 2017 May; 33(5):675-681. PubMed ID: 28063138
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Value of exercise stress electrocardiography for stratification of exercise capacity and left ventricular systolic and diastolic function on coronary slow flow: case-control study.
    Wang Y; Li J; Liu S; Mu L; Li G; Yu H; Yang J; Ma C
    BMC Cardiovasc Disord; 2019 Dec; 19(1):288. PubMed ID: 31830922
    [TBL] [Abstract][Full Text] [Related]  

  • 8. P wave peak time; a novel electrocardiographic parameter in the assessment of coronary no-reflow.
    Çağdaş M; Karakoyun S; Rencüzoğulları İ; Karabağ Y; Yesin M; Gürsoy MO; Artaç İ; İliş D; Efe SÇ; Taşar O; Karaca G
    J Electrocardiol; 2017; 50(5):584-590. PubMed ID: 28623012
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Layer-specific analysis of left ventricular myocardial contractility in patients with coronary slow-flow phenomenon.
    Wang Y; Ma C; Zhang Y; Guan Z; Liu S; Li Y; Yang J
    J Clin Ultrasound; 2016 Sep; 44(7):429-36. PubMed ID: 27086730
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The relationship between triglyceride/high-density lipoprotein cholesterol ratio and coronary slow-flow phenomenon.
    Aciksari G; Cetinkal G; Kocak M; Atici A; Celik FB; Caliskan M
    Int J Cardiovasc Imaging; 2022 Jan; 38(1):5-13. PubMed ID: 34453654
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Left Ventricular Myocardial Deformation Parameters Are Affected by Coronary Slow Flow Phenomenon: A Study of Speckle Tracking Echocardiography.
    Gulel O; Akcay M; Soylu K; Aksan G; Yuksel S; Zengin H; Meric M; Sahin M
    Echocardiography; 2016 May; 33(5):714-23. PubMed ID: 26668075
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Association between increased serum alkaline phosphatase and the coronary slow flow phenomenon.
    Wang Y; Liu MJ; Yang HM; Ma CY; Jia PY; Jia DL; Hou AJ
    BMC Cardiovasc Disord; 2018 Jul; 18(1):138. PubMed ID: 29973151
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Relationship between increased systemic immune-inflammation index and coronary slow flow phenomenon.
    Dai XT; Kong TZ; Zhang XJ; Luan B; Wang Y; Hou AJ
    BMC Cardiovasc Disord; 2022 Aug; 22(1):362. PubMed ID: 35941535
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prolonged P wave peak time is associated with the severity of coronary artery disease in patients with non-ST segment elevation myocardial infarction.
    Burak C; Yesin M; Tanık VO; Çağdaş M; Rencüzoğulları İ; Karabağ Y; Hamideyin Ş; İliş D; Çınar T; Altıntaş B; Baysal E
    J Electrocardiol; 2019; 55():138-143. PubMed ID: 31185366
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Incremental value of three-dimensional echocardiography for evaluating left atrial function in patients with coronary slow flow phenomenon: a case control study.
    Li J; Wang Y; Zhao C; Zhu Q; Li G; Yang J; Jia D; Ma C
    Cardiovasc Ultrasound; 2020 Feb; 18(1):6. PubMed ID: 32054491
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Can transthoracic Doppler echocardiography be used to detect coronary slow flow phenomenon?
    Nie SP; Geng LL; Wang X; Zhang XS; Yang Y; Liu BQ; Li J; Qiao Y; Liu XM; Luo TY; Dong JZ; Liu XH; Ma CS
    Chin Med J (Engl); 2010 Dec; 123(24):3529-33. PubMed ID: 22166625
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of Left and Right Atrial Function in Patients with Coronary Slow-Flow Phenomenon Using Two-Dimensional Speckle Tracking Echocardiography.
    Wang Y; Zhang Y; Ma C; Guan Z; Liu S; Zhang W; Li Y; Yang J
    Echocardiography; 2016 Jun; 33(6):871-80. PubMed ID: 26857684
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Novel electrocardiography parameter for paroxysmal atrial fibrillation in acute ischaemic stroke patients: P wave peak time.
    Öz A; Cinar T; Kızılto Güler C; Efe SÇ; Emre U; Karabağ T; Ayça B
    Postgrad Med J; 2020 Oct; 96(1140):584-588. PubMed ID: 32234836
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Homocysteine levels in patients with coronary slow flow phenomenon: A meta-analysis.
    Yu H; Wang BB; Zhao M; Feng F; Li HD
    PLoS One; 2023; 18(7):e0288036. PubMed ID: 37418362
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Echocardiographic and laboratory findings in coronary slow flow phenomenon: cross-sectional study and review.
    Seyyed Mohammadzad MH; Khademvatani K; Gardeshkhah S; Sedokani A
    BMC Cardiovasc Disord; 2021 May; 21(1):230. PubMed ID: 33952204
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.