224 related articles for article (PubMed ID: 35690334)
1. Non-invasive fetal monitoring: Fetal Heart Rate multimodal estimation from abdominal electrocardiography and phonocardiography.
Faisant MC; Fontecave-Jallon J; Genoux B; Rivet B; Dia N; Resendiz M; Riethmuller D; Equy V; Hoffmann P
J Gynecol Obstet Hum Reprod; 2022 Oct; 51(8):102421. PubMed ID: 35690334
[TBL] [Abstract][Full Text] [Related]
2. Non-invasive fetal monitoring using electrocardiography and phonocardiography: A preliminary study.
Gobillot S; Fontecave-Jallon J; Equy V; Rivet B; Gumery PY; Hoffmann P
J Gynecol Obstet Hum Reprod; 2018 Nov; 47(9):455-459. PubMed ID: 30144558
[TBL] [Abstract][Full Text] [Related]
3. Fetal heart rate estimation from a single phonocardiogram signal using non-negative matrix factorization.
Dia N; Fontecave-Jallon J; Gumery PY; Rivet B
Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():5983-5986. PubMed ID: 31947210
[TBL] [Abstract][Full Text] [Related]
4. Intrapartum heart rate ambiguity: a comparison of cardiotocogram and abdominal fetal electrocardiogram with maternal electrocardiogram.
Reinhard J; Hayes-Gill BR; Schiermeier S; Hatzmann H; Heinrich TM; Louwen F
Gynecol Obstet Invest; 2013; 75(2):101-8. PubMed ID: 23328351
[TBL] [Abstract][Full Text] [Related]
5. Misidentification of maternal heart rate as fetal on cardiotocography during the second stage of labor: the role of the fetal electrocardiograph.
Nurani R; Chandraharan E; Lowe V; Ugwumadu A; Arulkumaran S
Acta Obstet Gynecol Scand; 2012 Dec; 91(12):1428-32. PubMed ID: 22881463
[TBL] [Abstract][Full Text] [Related]
6. A Comparative Study on Fetal Heart Rates Estimated from Fetal Phonography and Cardiotocography.
Ibrahim EA; Al Awar S; Balayah ZH; Hadjileontiadis LJ; Khandoker AH
Front Physiol; 2017; 8():764. PubMed ID: 29089896
[TBL] [Abstract][Full Text] [Related]
7. Validation of beat by beat fetal heart signals acquired from four-channel fetal phonocardiogram with fetal electrocardiogram in healthy late pregnancy.
Khandoker A; Ibrahim E; Oshio S; Kimura Y
Sci Rep; 2018 Sep; 8(1):13635. PubMed ID: 30206289
[TBL] [Abstract][Full Text] [Related]
8. Quality of fetal heart rate monitoring with transabdominal fetal ECG during maternal movement in labor: A prospective study.
Reis-de-Carvalho C; Nogueira P; Ayres-de-Campos D
Acta Obstet Gynecol Scand; 2022 Nov; 101(11):1269-1275. PubMed ID: 35959521
[TBL] [Abstract][Full Text] [Related]
9. Longitudinal study of computerized cardiotocography in early fetal growth restriction.
Wolf H; Arabin B; Lees CC; Oepkes D; Prefumo F; Thilaganathan B; Todros T; Visser GHA; Bilardo CM; Derks JB; Diemert A; Duvekot JJ; Ferrazzi E; Frusca T; Hecher K; Marlow N; Martinelli P; Ostermayer E; Papageorghiou AT; Scheepers HCJ; Schlembach D; Schneider KTM; Valcamonico A; van Wassenaer-Leemhuis A; Ganzevoort W;
Ultrasound Obstet Gynecol; 2017 Jul; 50(1):71-78. PubMed ID: 27484356
[TBL] [Abstract][Full Text] [Related]
10. Hidden Markov model in nonnegative matrix factorization for fetal heart rate estimation using physiological priors.
Reséndiz Rojas M; Fontecave-Jallon J; Rivet B
Physiol Meas; 2022 Oct; 43(10):. PubMed ID: 36113452
[No Abstract] [Full Text] [Related]
11. Is short-term-variation of fetal-heart-rate a better predictor of fetal acidaemia in labour? A feasibility study.
Kapaya H; Jacques R; Almond T; Rosser MH; Anumba D
PLoS One; 2020; 15(8):e0236982. PubMed ID: 32745099
[TBL] [Abstract][Full Text] [Related]
12. Adaptive filtering in ECG monitoring of the fetal heart rate.
Frank TH; Blaumanis OR; Gibbs RK; Wells RK
J Electrocardiol; 1987 Oct; 20 Suppl():108-13. PubMed ID: 3694088
[TBL] [Abstract][Full Text] [Related]
13. Separation and Analysis of Fetal-ECG Signals From Compressed Sensed Abdominal ECG Recordings.
Da Poian G; Bernardini R; Rinaldo R
IEEE Trans Biomed Eng; 2016 Jun; 63(6):1269-79. PubMed ID: 26513775
[TBL] [Abstract][Full Text] [Related]
14. Heart rate estimation and validation algorithm for fetal phonocardiography.
Bhaskaran A; J SK; George S; Arora M
Physiol Meas; 2022 Jul; 43(7):. PubMed ID: 35724646
[No Abstract] [Full Text] [Related]
15. Use of Deep Learning to Detect the Maternal Heart Rate and False Signals on Fetal Heart Rate Recordings.
Boudet S; Houzé de l'Aulnoit A; Peyrodie L; Demailly R; Houzé de l'Aulnoit D
Biosensors (Basel); 2022 Aug; 12(9):. PubMed ID: 36140076
[TBL] [Abstract][Full Text] [Related]
16. A novel LabVIEW-based multi-channel non-invasive abdominal maternal-fetal electrocardiogram signal generator.
Martinek R; Kelnar M; Koudelka P; Vanus J; Bilik P; Janku P; Nazeran H; Zidek J
Physiol Meas; 2016 Feb; 37(2):238-56. PubMed ID: 26799770
[TBL] [Abstract][Full Text] [Related]
17. Sequential Total Variation Denoising for the Extraction of Fetal ECG from Single-Channel Maternal Abdominal ECG.
Lee KJ; Lee B
Sensors (Basel); 2016 Jul; 16(7):. PubMed ID: 27376296
[TBL] [Abstract][Full Text] [Related]
18. STAN S21 fetal heart monitor for fetal surveillance during labor: an observational study in 637 patients.
Kwee A; van der Hoorn-van den Beld CW; Veerman J; Dekkers AH; Visser GH
J Matern Fetal Neonatal Med; 2004 Jun; 15(6):400-7. PubMed ID: 15280112
[TBL] [Abstract][Full Text] [Related]
19. Comparison of non-invasive fetal electrocardiogram to Doppler cardiotocogram during the 1st stage of labor.
Reinhard J; Hayes-Gill BR; Yi Q; Hatzmann H; Schiermeier S
J Perinat Med; 2010 Mar; 38(2):179-85. PubMed ID: 20121540
[TBL] [Abstract][Full Text] [Related]
20. FHR patterns that become significant in connection with ST waveform changes and metabolic acidosis at birth.
Rosén KG; Norén H; Carlsson A
J Matern Fetal Neonatal Med; 2019 Oct; 32(19):3288-3293. PubMed ID: 29621906
[No Abstract] [Full Text] [Related]
[Next] [New Search]