These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 35696772)

  • 1. Model validation for estimating taper microgroove deformation during total hip arthroplasty head-neck assembly.
    Godoy M; Gustafson JA; Hertzler JS; Bischoff JE; Pourzal R; Lundberg HJ
    J Biomech; 2022 Jul; 140():111172. PubMed ID: 35696772
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Contact conditions for total hip head-neck modular taper junctions with microgrooved stem tapers.
    Bechstedt M; Gustafson JA; Mell SP; Gührs J; Morlock MM; Levine BR; Lundberg HJ
    J Biomech; 2020 Apr; 103():109689. PubMed ID: 32139099
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Interaction of surface topography and taper mismatch on head-stem modular junction contact mechanics during assembly in modern total hip replacement.
    Gustafson JA; Mell SP; Levine BR; Pourzal R; Lundberg HJ
    J Orthop Res; 2023 Feb; 41(2):418-425. PubMed ID: 35488727
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Insights into Imprinting: How Is the Phenomenon of Tribocorrosion at Head-Neck Taper Interfaces Related to Corrosion, Fretting, and Implant Design Parameters?
    Bormann T; Müller U; Gibmeier J; Mai PT; Renkawitz T; Kretzer JP
    Clin Orthop Relat Res; 2022 Aug; 480(8):1585-1600. PubMed ID: 35383614
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions?
    Pourzal R; Hall DJ; Ha NQ; Urban RM; Levine BR; Jacobs JJ; Lundberg HJ
    Clin Orthop Relat Res; 2016 Oct; 474(10):2232-42. PubMed ID: 27339123
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study.
    Arnholt CM; MacDonald DW; Underwood RJ; Guyer EP; Rimnac CM; Kurtz SM; ; Mont MA; Klein GR; Lee GC; Chen AF; Hamlin BR; Cates HE; Malkani AL; Kraay MJ
    J Arthroplasty; 2017 Apr; 32(4):1363-1373. PubMed ID: 28111124
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of impact assembly on the interface deformation and fretting corrosion of modular hip tapers: An in vitro study.
    Panagiotidou A; Cobb T; Meswania J; Skinner J; Hart A; Haddad F; Blunn G
    J Orthop Res; 2018 Jan; 36(1):405-416. PubMed ID: 28485507
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ceramic Heads Decrease Metal Release Caused by Head-taper Fretting and Corrosion.
    Kocagoz SB; Underwood RJ; MacDonald DW; Gilbert JL; Kurtz SM
    Clin Orthop Relat Res; 2016 Apr; 474(4):985-94. PubMed ID: 26847452
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Modelling changes in modular taper micromechanics due to surgeon assembly technique in total hip arthroplasty.
    Gustafson JA; Pourzal R; Levine BR; Jacobs JJ; Lundberg HJ
    Bone Joint J; 2020 Jul; 102-B(7_Supple_B):33-40. PubMed ID: 32600210
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Is taper corrosion in modular revision hip stem junctions associated with patient or implant specific factors? A retrieval analysis.
    Bormann T; Kretzer JP; Jaeger S; Lohmann CH
    J Mech Behav Biomed Mater; 2024 Feb; 150():106326. PubMed ID: 38141361
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessing Taper Geometry, Head Size, Head Material, and Their Interactions in Taper Fretting Corrosion of Retrieved Total Hip Arthroplasty Implants.
    El-Zein ZS; Gehrke CK; Croley JS; Siljander MP; Mallow MA; Flierl MA; Verner JJ; Baker EA
    J Arthroplasty; 2021 Jul; 36(7S):S386-S394.e4. PubMed ID: 33832796
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Does Taper Design Affect Taper Fretting Corrosion in Ceramic-on-Polyethylene Total Hip Arthroplasty? A Retrieval Analysis.
    Siljander MP; Gehrke CK; Wheeler SD; Sobh AH; Moore DD; Flierl MA; Baker EA
    J Arthroplasty; 2019 Jul; 34(7S):S366-S372.e2. PubMed ID: 31000401
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Otto Aufranc Award: Large Heads Do Not Increase Damage at the Head-neck Taper of Metal-on-polyethylene Total Hip Arthroplasties.
    Triantafyllopoulos GK; Elpers ME; Burket JC; Esposito CI; Padgett DE; Wright TM
    Clin Orthop Relat Res; 2016 Feb; 474(2):330-8. PubMed ID: 26208607
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Variability in stem taper surface topography affects the degree of corrosion and fretting in total hip arthroplasty.
    Stockhausen KE; Riedel C; Belinski AV; Rothe D; Gehrke T; Klebig F; Gebauer M; Amling M; Citak M; Busse B
    Sci Rep; 2021 Apr; 11(1):9348. PubMed ID: 33931680
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Does the Additional Articulation in Retrieved Bipolar Hemiarthroplasty Implants Decrease Trunnionosis Compared to Total Hip Arthroplasty?
    Del Balso C; Teeter MG; Tan SC; Lanting BA; Howard JL
    J Arthroplasty; 2018 Jan; 33(1):268-272. PubMed ID: 29033155
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Same Same but Different? 12/14 Stem and Head Tapers in Total Hip Arthroplasty.
    Mueller U; Braun S; Schroeder S; Sonntag R; Kretzer JP
    J Arthroplasty; 2017 Oct; 32(10):3191-3199. PubMed ID: 28552447
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Flexural Rigidity, Taper Angle, and Contact Length Affect Fretting of the Femoral Stem Trunnion in Total Hip Arthroplasty.
    Kao YY; Koch CN; Wright TM; Padgett DE
    J Arthroplasty; 2016 Sep; 31(9 Suppl):254-8. PubMed ID: 27094241
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Trunnionosis: Does Head Size Affect Fretting and Corrosion in Total Hip Arthroplasty?
    Del Balso C; Teeter MG; Tan SC; Howard JL; Lanting BA
    J Arthroplasty; 2016 Oct; 31(10):2332-6. PubMed ID: 27067470
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of Taper surface topographies on contact deformation and stresses.
    Diaz-Lopez RA; Wen PH; Shelton JC
    J Mech Behav Biomed Mater; 2023 Dec; 148():106213. PubMed ID: 37952504
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Self-reinforced poly(ether ether ketone) and polyethylene composite gaskets for prevention of mechanically-assisted corrosion in modular taper junctions: Seating, micromotion and short-term fretting corrosion.
    Ouellette ES; Smith SM; Gilbert JL
    J Mech Behav Biomed Mater; 2021 Jul; 119():104454. PubMed ID: 33826987
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.