These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 35705359)

  • 21. Long-term clinical and angiographic follow-up results of the dual-layer flow diverter device (FRED) for the treatment of intracranial aneurysms in a multicenter study.
    Dinc H; Saatci I; Oguz S; Baltacioglu F; Yildiz A; Donmez H; Belet U; Onal B; Andic C; Koc O; Kocak O; Koroglu M; Cetin M; Cekirge HS
    Neuroradiology; 2021 Jun; 63(6):943-952. PubMed ID: 33392735
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Prospective study on embolization of intracranial aneurysms with the pipeline device (PREMIER study): 3-year results with the application of a flow diverter specific occlusion classification.
    Hanel RA; Cortez GM; Lopes DK; Nelson PK; Siddiqui AH; Jabbour P; Mendes Pereira V; István IS; Zaidat OO; Bettegowda C; Colby GP; Mokin M; Schirmer CM; Hellinger FR; Given C; Krings T; Taussky P; Toth G; Fraser JF; Chen M; Priest R; Kan P; Fiorella D; Frei D; Aagaard-Kienitz B; Diaz O; Malek AM; Cawley CM; Puri AS; Kallmes DF
    J Neurointerv Surg; 2023 Mar; 15(3):248-254. PubMed ID: 35292570
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Pipeline for uncoilable or failed aneurysms: 3-year follow-up results.
    Becske T; Potts MB; Shapiro M; Kallmes DF; Brinjikji W; Saatci I; McDougall CG; Szikora I; Lanzino G; Moran CJ; Woo HH; Lopes DK; Berez AL; Cher DJ; Siddiqui AH; Levy EI; Albuquerque FC; Fiorella DJ; Berentei Z; Marosföi M; Cekirge SH; Nelson PK
    J Neurosurg; 2017 Jul; 127(1):81-88. PubMed ID: 27739944
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Long-term results and comparison of flow re-direction endoluminal device and pipeline embolization device in endovascular treatment of intracranial carotid aneurysms.
    Gündoğmuş CA; Sabet S; Baltacıoğlu NA; Türeli D; Bayri Y; Baltacıoğlu F
    Interv Neuroradiol; 2022 Jun; 28(3):302-310. PubMed ID: 34515551
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The LUNA aneurysm embolization system for intracranial aneurysm treatment: short-term, mid-term and long-term clinical and angiographic results.
    Piotin M; Biondi A; Sourour N; Mounayer C; Jaworski M; Mangiafico S; Andersson T; Söderman M; Goffette P; Anxionnat R; Blanc R
    J Neurointerv Surg; 2018 Dec; 10(12):e34. PubMed ID: 29669856
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The DERIVO 2 Heal Embolization Device in the Treatment of Ruptured and Unruptured Intracranial Aneurysms: a Retrospective Multicenter Study.
    Schwab R; Kabbasch C; Goertz L; Kaschner M; Weiss D; Loehr C; Wensing H; Bester M; Simgen A; Kemmling A; Wendl C; Fuchs E; Thormann M; Behme D; Nordmeyer H
    Clin Neuroradiol; 2024 Aug; ():. PubMed ID: 39172220
    [TBL] [Abstract][Full Text] [Related]  

  • 27. North American multicenter experience with the Flow Redirection Endoluminal Device in the treatment of intracranial aneurysms.
    Khorasanizadeh M; Shutran M; Schirmer CM; Salem MM; Ringer AJ; Grandhi R; Mitha AP; Levitt MR; Jankowitz BT; Taussky P; Thomas AJ; Moore JM; Ogilvy CS
    J Neurosurg; 2023 Apr; 138(4):933-943. PubMed ID: 36087324
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Safety and Effectiveness of the Pipeline Flex Embolization Device With Shield Technology for the Treatment of Intracranial Aneurysms: Midterm Results From a Multicenter Study.
    Trivelato FP; Wajnberg E; Rezende MTS; Ulhôa AC; Piske RL; Abud TG; de Castro-Afonso LH; Abath CGC; Nakiri GS; Araújo JFS; Silva JLJ; Tosello RT; Vanzin JR; Manzato LB; Baccin CE; da Mota BAA; Abud DG
    Neurosurgery; 2020 Jul; 87(1):104-111. PubMed ID: 31504821
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Treatment of Distal Anterior Cerebral Artery Aneurysms with Flow-Diverter Stents: A Single-Center Experience.
    Cagnazzo F; Cappucci M; Dargazanli C; Lefevre PH; Gascou G; Riquelme C; Bonafe A; Costalat V
    AJNR Am J Neuroradiol; 2018 Jun; 39(6):1100-1106. PubMed ID: 29650782
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Treatment of intracranial aneurysms by flow diverter devices: long-term results from a single center.
    Briganti F; Napoli M; Leone G; Marseglia M; Mariniello G; Caranci F; Tortora F; Maiuri F
    Eur J Radiol; 2014 Sep; 83(9):1683-90. PubMed ID: 24985339
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Intracranial Aneurysms in Children: The Role of Stenting and Flow-Diversion.
    Vargas SA; Diaz C; Herrera DA; Dublin AB
    J Neuroimaging; 2016; 26(1):41-5. PubMed ID: 26459235
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Open-cell stent-assisted coiling for the treatment of paraclinoid aneurysms: traditional endovascular treatment is still not out of date.
    Ni H; Zhao LB; Liu S; Jia ZY; Cao YZ; Shi HB
    Neuroradiology; 2021 Sep; 63(9):1521-1530. PubMed ID: 33630124
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Long-term clinical and angiographic results of Neuroform stent-assisted coil embolization in wide-necked intracranial aneurysms.
    Santillan A; Greenberg E; Patsalides A; Salvaggio K; Riina HA; Gobin YP
    Neurosurgery; 2012 May; 70(5):1232-7; discussion 1237. PubMed ID: 22095221
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A single-centre experience and follow-up of patients with endovascular coiling of large and giant intracranial aneurysms with parent artery preservation.
    Gao X; Liang G; Li Z; Wei X; Cao P
    J Clin Neurosci; 2012 Mar; 19(3):364-9. PubMed ID: 22277568
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Pipeline embolization device for recurrence of previously treated aneurysms.
    Dornbos D; Karras CL; Wenger N; Priddy B; Youssef P; Nimjee SM; Powers CJ
    Neurosurg Focus; 2017 Jun; 42(6):E8. PubMed ID: 28565989
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The safety and efficacy of low profile visualized intraluminal support (LVIS) stents in assisting coil embolization of intracranial saccular aneurysms: a single center experience.
    Feng Z; Fang Y; Xu Y; Hong B; Zhao W; Liu J; Huang Q
    J Neurointerv Surg; 2016 Nov; 8(11):1192-1196. PubMed ID: 26747876
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Flow diverter stents in the treatment of recanalized intracranial aneurysms.
    Akgul E; Onan HB; Islek I; Tonge M; Durmus Y; Barburoglu M; Azizova A; Erol C; Hakyemez B; Sencer S; Aydin K; Arat A
    Interv Neuroradiol; 2021 Aug; 27(4):481-489. PubMed ID: 33509011
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Neurovascular reconstruction with flow diverter stents for the treatment of 87 intracranial aneurysms: Clinical results.
    Giacomini L; Piske RL; Baccin CE; Barroso M; Joaquim AF; Tedeschi H
    Interv Neuroradiol; 2015 Jun; 21(3):292-9. PubMed ID: 25964435
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Pipeline-assisted coiling versus pipeline in flow diversion treatment of intracranial aneurysms.
    Sweid A; Atallah E; Herial N; Saad H; Mouchtouris N; Barros G; Gooch MR; Tjoumakaris S; Zarzour H; Hasan D; Chalouhi N; Rosenwasser RH; Jabbour P
    J Clin Neurosci; 2018 Dec; 58():20-24. PubMed ID: 30454690
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Single-stage endovascular treatment of multiple intracranial aneurysms with combined endovascular techniques: is it safe to treat all at once?
    Andic C; Aydemir F; Kardes O; Gedikoglu M; Akin S
    J Neurointerv Surg; 2017 Nov; 9(11):1069-1074. PubMed ID: 27977003
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.