These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
147 related articles for article (PubMed ID: 35705858)
1. Peak broadening caused by using different micro-liquid chromatography detectors. Werres T; Schmidt TC; Teutenberg T Anal Bioanal Chem; 2022 Aug; 414(20):6107-6114. PubMed ID: 35705858 [TBL] [Abstract][Full Text] [Related]
2. [Research advances in nano liquid chromatography instrumentation]. Yang S; Li N; Ma Z; Tang T; Li T Se Pu; 2021 Oct; 39(10):1065-1076. PubMed ID: 34505428 [TBL] [Abstract][Full Text] [Related]
3. The impact of extra-column band broadening on the chromatographic efficiency of 5 cm long narrow-bore very efficient columns. Fekete S; Fekete J J Chromatogr A; 2011 Aug; 1218(31):5286-91. PubMed ID: 21726868 [TBL] [Abstract][Full Text] [Related]
4. Band broadening in fast gradient high-performance liquid chromatography: application to the second generation of 4.6 mm I.D. silica monolithic columns. Gritti F; Guiochon G J Chromatogr A; 2012 May; 1238():77-90. PubMed ID: 22503619 [TBL] [Abstract][Full Text] [Related]
5. Understanding and diminishing the extra-column band broadening effects in supercritical fluid chromatography. De Pauw R; Shoykhet Choikhet K; Desmet G; Broeckhoven K J Chromatogr A; 2015 Jul; 1403():132-7. PubMed ID: 26054561 [TBL] [Abstract][Full Text] [Related]
6. Rapid development of core-shell column technology: accurate measurements of the intrinsic column efficiency of narrow-bore columns packed with 4.6 down to 1.3 μm superficially porous particles. Gritti F; Guiochon G J Chromatogr A; 2014 Mar; 1333():60-9. PubMed ID: 24529958 [TBL] [Abstract][Full Text] [Related]
7. Instrument contributions to resolution and sensitivity in ultra high performance liquid chromatography using small bore columns: comparison of diode array and triple quadrupole mass spectrometry detection. Buckenmaier S; Miller CA; van de Goor T; Dittmann MM J Chromatogr A; 2015 Jan; 1377():64-74. PubMed ID: 25547218 [TBL] [Abstract][Full Text] [Related]
8. Extraction of intrinsic column peak profiles of narrow-bore and microbore columns by peak deconvolution methods. Gritti F; Wahab F Anal Chim Acta; 2021 Oct; 1180():338851. PubMed ID: 34538318 [TBL] [Abstract][Full Text] [Related]
9. Efficiency of short, small-diameter columns for reversed-phase liquid chromatography under practical operating conditions. Ma Y; Chassy AW; Miyazaki S; Motokawa M; Morisato K; Uzu H; Ohira M; Furuno M; Nakanishi K; Minakuchi H; Mriziq K; Farkas T; Fiehn O; Tanaka N J Chromatogr A; 2015 Feb; 1383():47-57. PubMed ID: 25648581 [TBL] [Abstract][Full Text] [Related]
10. Effect of pre- and post-column band broadening on the performance of high-speed chromatography columns under isocratic and gradient conditions. Vanderlinden K; Broeckhoven K; Vanderheyden Y; Desmet G J Chromatogr A; 2016 Apr; 1442():73-82. PubMed ID: 26987413 [TBL] [Abstract][Full Text] [Related]
11. Development of a particle packed bed model for homogeneity evaluation of liquid chromatography column. Kubo T; Ichikawa M; Adachi T; Watabe Y; Naito T; Otuka K J Chromatogr A; 2023 Aug; 1705():464171. PubMed ID: 37385150 [TBL] [Abstract][Full Text] [Related]
13. Accurate measurements of the true column efficiency and of the instrument band broadening contributions in the presence of a chromatographic column. Gritti F; Guiochon G J Chromatogr A; 2014 Jan; 1327():49-56. PubMed ID: 24438831 [TBL] [Abstract][Full Text] [Related]
14. Effect of column dimension on observed column efficiency in very high pressure liquid chromatography. Wu N; Bradley AC J Chromatogr A; 2012 Oct; 1261():113-20. PubMed ID: 22683184 [TBL] [Abstract][Full Text] [Related]
15. Scalability of pre-packed preparative chromatography columns with different diameters and lengths taking into account extra column effects. Schweiger S; Jungbauer A J Chromatogr A; 2018 Feb; 1537():66-74. PubMed ID: 29373126 [TBL] [Abstract][Full Text] [Related]
16. Implications of dispersion in connecting capillaries for separation systems involving post-column flow splitting. Gunnarson C; Lauer T; Willenbring H; Larson E; Dittmann M; Broeckhoven K; Stoll DR J Chromatogr A; 2021 Feb; 1639():461893. PubMed ID: 33524933 [TBL] [Abstract][Full Text] [Related]
17. Effect of parallel segmented flow chromatography on the height equivalent to a theoretical plate III--influence of the column length, particle diameter, and the molecular weight of the analyte on the efficiency gain. Gritti F; Pynt J; Soliven A; Dennis GR; Shalliker RA; Guiochon G J Chromatogr A; 2014 Mar; 1333():32-44. PubMed ID: 24529404 [TBL] [Abstract][Full Text] [Related]
18. Characterization of the efficiency of microbore liquid chromatography columns by van Deemter and kinetic plot analysis. Hetzel T; Loeker D; Teutenberg T; Schmidt TC J Sep Sci; 2016 Oct; 39(20):3889-3897. PubMed ID: 27553706 [TBL] [Abstract][Full Text] [Related]
19. The impact of column connection on band broadening in very high pressure liquid chromatography. Stankovich JJ; Gritti F; Stevenson PG; Guiochon G J Sep Sci; 2013 Sep; 36(17):2709-17. PubMed ID: 23900740 [TBL] [Abstract][Full Text] [Related]
20. Contribution of various types of liquid chromatography-mass spectrometry instruments to band broadening in fast analysis. Spaggiari D; Fekete S; Eugster PJ; Veuthey JL; Geiser L; Rudaz S; Guillarme D J Chromatogr A; 2013 Oct; 1310():45-55. PubMed ID: 23993747 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]