These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 35709059)

  • 21. Nonlinear pulse compression to 43  W GW-class few-cycle pulses at 2  μm wavelength.
    Gebhardt M; Gaida C; Heuermann T; Stutzki F; Jauregui C; Antonio-Lopez J; Schulzgen A; Amezcua-Correa R; Limpert J; Tünnermann A
    Opt Lett; 2017 Oct; 42(20):4179-4182. PubMed ID: 29028042
    [TBL] [Abstract][Full Text] [Related]  

  • 22. 53 W average power CEP-stabilized OPCPA system delivering 5.5 TW few cycle pulses at 1 kHz repetition rate.
    Budriūnas R; Stanislauskas T; Adamonis J; Aleknavičius A; Veitas G; Gadonas D; Balickas S; Michailovas A; Varanavičius A
    Opt Express; 2017 Mar; 25(5):5797-5806. PubMed ID: 28380838
    [TBL] [Abstract][Full Text] [Related]  

  • 23. High average power nonlinear compression to 4  GW, sub-50  fs pulses at 2  μm wavelength.
    Gebhardt M; Gaida C; Stutzki F; Hädrich S; Jauregui C; Limpert J; Tünnermann A
    Opt Lett; 2017 Feb; 42(4):747-750. PubMed ID: 28198855
    [TBL] [Abstract][Full Text] [Related]  

  • 24. 12  mJ kW-class ultrafast fiber laser system using multidimensional coherent pulse addition.
    Kienel M; Müller M; Klenke A; Limpert J; Tünnermann A
    Opt Lett; 2016 Jul; 41(14):3343-6. PubMed ID: 27420531
    [TBL] [Abstract][Full Text] [Related]  

  • 25. 530 W, 1.3 mJ, four-channel coherently combined femtosecond fiber chirped-pulse amplification system.
    Klenke A; Breitkopf S; Kienel M; Gottschall T; Eidam T; Hädrich S; Rothhardt J; Limpert J; Tünnermann A
    Opt Lett; 2013 Jul; 38(13):2283-5. PubMed ID: 23811903
    [TBL] [Abstract][Full Text] [Related]  

  • 26. 2.05  µm chirped pulse amplification system at a 1  kHz repetition rate-2.4  ps pulses with 17  GW peak power.
    von Grafenstein L; Bock M; Ueberschaer D; Koç A; Griebner U; Elsaesser T
    Opt Lett; 2020 Jul; 45(14):3836-3839. PubMed ID: 32667297
    [TBL] [Abstract][Full Text] [Related]  

  • 27. 90 W average power 100 microJ energy femtosecond fiber chirped-pulse amplification system.
    Röser F; Schimpf D; Schmidt O; Ortaç B; Rademaker K; Limpert J; Tünnermann A
    Opt Lett; 2007 Aug; 32(15):2230-2. PubMed ID: 17671593
    [TBL] [Abstract][Full Text] [Related]  

  • 28. 1.5 mJ, 6.4 fs parametric chirped-pulse amplification system at 1 kHz.
    Adachi S; Ishii H; Kanai T; Ishii N; Kosuge A; Watanabe S
    Opt Lett; 2007 Sep; 32(17):2487-9. PubMed ID: 17767280
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Amplification of nanosecond pulses to megawatt peak power levels in Tm3+-doped photonic crystal fiber rod.
    Gaida C; Gebhardt M; Kadwani P; Leick L; Broeng J; Shah L; Richardson M
    Opt Lett; 2013 Mar; 38(5):691-3. PubMed ID: 23455267
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Sub-picosecond pulses at 100 W average power from a Yb:YLF chirped-pulse amplification system.
    Miller DE; Zapata LE; Ripin DJ; Fan TY
    Opt Lett; 2012 Jul; 37(13):2700-2. PubMed ID: 22743500
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Sub-200  fs, 344  MHz mode-locked Tm-doped fiber laser.
    Lai W; Zhang H; Zhu Z; Yan P; Ruan S; Sun Z; Wang J
    Opt Lett; 2020 Oct; 45(19):5492-5495. PubMed ID: 33001928
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Coherent combination of two Tm-doped fiber amplifiers.
    Gaida C; Kienel M; Müller M; Klenke A; Gebhardt M; Stutzki F; Jauregui C; Limpert J; Tünnermann A
    Opt Lett; 2015 May; 40(10):2301-4. PubMed ID: 26393724
    [TBL] [Abstract][Full Text] [Related]  

  • 33. 1  kW, 10  mJ, 120  fs coherently combined fiber CPA laser system.
    Stark H; Buldt J; Müller M; Klenke A; Limpert J
    Opt Lett; 2021 Mar; 46(5):969-972. PubMed ID: 33649633
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Carrier-envelope phase stable few-cycle laser system delivering more than 100 W, 1 mJ, sub-2-cycle pulses.
    Hädrich S; Shestaev E; Tschernajew M; Stutzki F; Walther N; Just F; Kienel M; Seres I; Jójárt P; Bengery Z; Gilicze B; Várallyay Z; Börzsönyi Á; Müller M; Grebing C; Klenke A; Hoff D; Paulus GG; Eidam T; Limpert J
    Opt Lett; 2022 Mar; 47(6):1537-1540. PubMed ID: 35290358
    [TBL] [Abstract][Full Text] [Related]  

  • 35. All-fiber ultrafast amplifier at 1.9 μm based on thulium-doped normal dispersion fiber and LMA fiber compressor.
    Voropaev V; Batov D; Voronets A; Vlasov D; Jafari R; Donodin A; Tarabrin M; Trebino R; Lazarev V
    Sci Rep; 2021 Dec; 11(1):23693. PubMed ID: 34880282
    [TBL] [Abstract][Full Text] [Related]  

  • 36. High-power sub-15  fs nonlinear pulse compression at 515  nm of an ultrafast Yb-doped fiber amplifier.
    Descamps D; Guichard F; Petit S; Beauvarlet S; Comby A; Lavenu L; Zaouter Y
    Opt Lett; 2021 Apr; 46(8):1804-1807. PubMed ID: 33857074
    [TBL] [Abstract][Full Text] [Related]  

  • 37. High-average-power kilohertz-repetition-rate sub-100-fs Ti:sapphire amplifier system.
    Fu Q; Seier F; Gayen SK; Alfano RR
    Opt Lett; 1997 May; 22(10):712-4. PubMed ID: 18185637
    [TBL] [Abstract][Full Text] [Related]  

  • 38. 230-kW peak power femtosecond pulses from a high power tunable source based on amplification in Tm-doped fiber.
    Imeshev G; Fermann M
    Opt Express; 2005 Sep; 13(19):7424-31. PubMed ID: 19498767
    [TBL] [Abstract][Full Text] [Related]  

  • 39. All-fiber high-average power nanosecond-pulsed master-oscillator power amplifier at 2  μm with mJ-level pulse energy.
    Wang X; Jin X; Zhou P; Wang X; Xiao H; Liu Z
    Appl Opt; 2016 Mar; 55(8):1941-5. PubMed ID: 26974786
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Tunable thulium-doped mode-locked fiber laser with watt-level average power.
    Wei K; Zhang H; Yang K; Zhu H; Yan P; Ruan S; Wang J
    Opt Lett; 2022 Mar; 47(6):1545-1548. PubMed ID: 35290360
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.