These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 35716109)

  • 1. Comparison of Improved Unidirectional Dual Velocity-Encoding MRI Methods.
    Franco P; Ma L; Schnell S; Carrillo H; Montalba C; Markl M; Bertoglio C; Uribe S
    J Magn Reson Imaging; 2023 Mar; 57(3):763-773. PubMed ID: 35716109
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Efficient triple-VENC phase-contrast MRI for improved velocity dynamic range.
    Ma LE; Markl M; Chow K; Vali A; Wu C; Schnell S
    Magn Reson Med; 2020 Feb; 83(2):505-520. PubMed ID: 31423646
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Phase unwrapping in 4D MR flow with a 4D single-step laplacian algorithm.
    Loecher M; Schrauben E; Johnson KM; Wieben O
    J Magn Reson Imaging; 2016 Apr; 43(4):833-42. PubMed ID: 26417641
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimal Dual-VENC Unwrapping in Phase-Contrast MRI.
    Carrillo H; Osses A; Uribe S; Bertoglio C
    IEEE Trans Med Imaging; 2019 May; 38(5):1263-1270. PubMed ID: 30475716
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multi-VENC acquisition of four-dimensional phase-contrast MRI to improve precision of velocity field measurement.
    Ha H; Kim GB; Kweon J; Kim YH; Kim N; Yang DH; Lee SJ
    Magn Reson Med; 2016 May; 75(5):1909-19. PubMed ID: 26059014
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accelerated dual-venc 4D flow MRI for neurovascular applications.
    Schnell S; Ansari SA; Wu C; Garcia J; Murphy IG; Rahman OA; Rahsepar AA; Aristova M; Collins JD; Carr JC; Markl M
    J Magn Reson Imaging; 2017 Jul; 46(1):102-114. PubMed ID: 28152256
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Velocity reconstruction with nonconvex optimization for low-velocity-encoding phase-contrast MRI.
    Loecher M; Ennis DB
    Magn Reson Med; 2018 Jul; 80(1):42-52. PubMed ID: 29130519
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dual-V
    Callahan S; Singam NS; Kendrick M; Negahdar MJ; Wang H; Stoddard MF; Amini AA
    J Magn Reson Imaging; 2020 Jul; 52(1):117-128. PubMed ID: 31850597
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Spatiotemporal phase unwrapping for real-time phase-contrast flow MRI.
    Untenberger M; Hüllebrand M; Tautz L; Joseph AA; Voit D; Merboldt KD; Frahm J
    Magn Reson Med; 2015 Oct; 74(4):964-70. PubMed ID: 25302683
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparison of phase unwrapping methods in velocity-encoded MRI for aortic flows.
    Löcke M; Garay Labra JE; Franco P; Uribe S; Bertoglio C
    Magn Reson Med; 2023 Nov; 90(5):2102-2115. PubMed ID: 37345719
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Divergence-Free Constrained Phase Unwrapping and Denoising for 4D Flow MRI Using Weighted Least-Squares.
    Zhang J; Rothenberger SM; Brindise MC; Scott MB; Berhane H; Baraboo JJ; Markl M; Rayz VL; Vlachos PP
    IEEE Trans Med Imaging; 2021 Dec; 40(12):3389-3399. PubMed ID: 34086567
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simultaneous Multi-VENC and Simultaneous Multi-Slice Phase Contrast Magnetic Resonance Imaging.
    Park S; Chen L; Townsend J; Lee H; Feinberg DA
    IEEE Trans Med Imaging; 2020 Mar; 39(3):742-752. PubMed ID: 31403409
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accelerated dual-venc 4D flow MRI with variable high-venc spatial resolution for neurovascular applications.
    Aristova M; Pang J; Ma Y; Ma L; Berhane H; Rayz V; Markl M; Schnell S
    Magn Reson Med; 2022 Oct; 88(4):1643-1658. PubMed ID: 35754143
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intracranial Blood Flow Quantification by Accelerated Dual-venc 4D Flow MRI: Comparison With Transcranial Doppler Ultrasound.
    Mahinrad S; Tan CO; Ma Y; Aristova M; Milstead AL; Lloyd-Jones D; Schnell S; Markl M; Sorond FA
    J Magn Reson Imaging; 2022 Oct; 56(4):1256-1264. PubMed ID: 35146822
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Variable velocity encoding in a three-dimensional, three-directional phase contrast sequence: Evaluation in phantom and volunteers.
    Nilsson A; Markenroth Bloch K; Carlsson M; Heiberg E; Ståhlberg F
    J Magn Reson Imaging; 2012 Dec; 36(6):1450-9. PubMed ID: 23065951
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multidirectional high-moment encoding in phase contrast MRI.
    Zwart NR; Pipe JG
    Magn Reson Med; 2013 Jun; 69(6):1553-64. PubMed ID: 22760964
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Seed prioritized unwrapping (SPUN) for MR phase imaging.
    Ye Y; Zhou F; Zong J; Lyu J; Chen Y; Zhang S; Zhang W; He Q; Li X; Li M; Zhang Q; Qing Z; Zhang B
    J Magn Reson Imaging; 2019 Jul; 50(1):62-70. PubMed ID: 30569494
    [TBL] [Abstract][Full Text] [Related]  

  • 18. 4D Dual-V
    Callahan S; Henn A; Kendrick M; Wang H; Negahdar MJ; Kheradvar A; Stoddard M; Amini A
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():1372-1375. PubMed ID: 30440647
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Venc Design and Velocity Estimation for Phase Contrast MRI.
    Zhao S; Ahmad R; Potter LC
    IEEE Trans Med Imaging; 2022 Dec; 41(12):3712-3724. PubMed ID: 35862337
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved estimation of velocity and flow rate using regularized three-point phase-contrast velocimetry.
    Herment A; Mousseaux E; Jolivet O; DeCesare A; Frouin F; Todd-Pokropek A; Bittoun J
    Magn Reson Med; 2000 Jul; 44(1):122-8. PubMed ID: 10893530
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.