BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

269 related articles for article (PubMed ID: 35717613)

  • 1. Spot-scanning hadron arc (SHArc) therapy: A proof of concept using single- and multi-ion strategies with helium, carbon, oxygen, and neon ions.
    Mein S; Kopp B; Tessonnier T; Liermann J; Abdollahi A; Debus J; Haberer T; Mairani A
    Med Phys; 2022 Sep; 49(9):6082-6097. PubMed ID: 35717613
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biological Dose Optimization for Particle Arc Therapy Using Helium and Carbon Ions.
    Mein S; Tessonnier T; Kopp B; Schömers C; Harrabi S; Abdollahi A; Debus J; Haberer T; Mairani A
    Int J Radiat Oncol Biol Phys; 2022 Oct; 114(2):334-348. PubMed ID: 35490991
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Spot-Scanning Hadron Arc (SHArc) Therapy: A Study With Light and Heavy Ions.
    Mein S; Tessonnier T; Kopp B; Harrabi S; Abdollahi A; Debus J; Haberer T; Mairani A
    Adv Radiat Oncol; 2021; 6(3):100661. PubMed ID: 33817410
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of cellular radioresponse on therapeutic helium-, carbon-, oxygen-, and neon-ion beams: a simulation study.
    Masuda T; Inaniwa T
    Phys Med Biol; 2024 Feb; 69(4):. PubMed ID: 38232394
    [No Abstract]   [Full Text] [Related]  

  • 5. Experimental validation of stochastic microdosimetric kinetic model for multi-ion therapy treatment planning with helium-, carbon-, oxygen-, and neon-ion beams.
    Inaniwa T; Suzuki M; Hyun Lee S; Mizushima K; Iwata Y; Kanematsu N; Shirai T
    Phys Med Biol; 2020 Feb; 65(4):045005. PubMed ID: 31968318
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and Validation of Single Field Multi-Ion Particle Therapy Treatments.
    Kopp B; Mein S; Dokic I; Harrabi S; Böhlen TT; Haberer T; Debus J; Abdollahi A; Mairani A
    Int J Radiat Oncol Biol Phys; 2020 Jan; 106(1):194-205. PubMed ID: 31610250
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Adaptation of stochastic microdosimetric kinetic model to hypoxia for hypo-fractionated multi-ion therapy treatment planning.
    Inaniwa T; Kanematsu N; Shinoto M; Koto M; Yamada S
    Phys Med Biol; 2021 Oct; 66(20):. PubMed ID: 34560678
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dose averaged linear energy transfer optimization for large sacral chordomas in carbon ion therapy.
    Schafasand M; Resch AF; Nachankar A; Góra J; Martino G; Traneus E; Glimelius L; Georg D; Fossati P; Carlino A; Stock M
    Med Phys; 2024 Jun; 51(6):3950-3960. PubMed ID: 38696546
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The relative biological effectiveness for carbon, nitrogen, and oxygen ion beams using passive and scanning techniques evaluated with fully 3D silicon microdosimeters.
    Tran LT; Bolst D; Guatelli S; Pogossov A; Petasecca M; Lerch MLF; Chartier L; Prokopovich DA; Reinhard MI; Povoli M; Kok A; Perevertaylo VL; Matsufuji N; Kanai T; Jackson M; Rosenfeld AB
    Med Phys; 2018 May; 45(5):2299-2308. PubMed ID: 29572856
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biophysical modeling and experimental validation of relative biological effectiveness (RBE) for
    Mein S; Dokic I; Klein C; Tessonnier T; Böhlen TT; Magro G; Bauer J; Ferrari A; Parodi K; Haberer T; Debus J; Abdollahi A; Mairani A
    Radiat Oncol; 2019 Jul; 14(1):123. PubMed ID: 31296232
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Inactivation of aerobic and hypoxic cells from three different cell lines by accelerated (3)He-, (12)C- and (20)Ne-ion beams.
    Furusawa Y; Fukutsu K; Aoki M; Itsukaichi H; Eguchi-Kasai K; Ohara H; Yatagai F; Kanai T; Ando K
    Radiat Res; 2000 Nov; 154(5):485-96. PubMed ID: 11025645
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Implementation of spot scanning dose optimization and dose calculation for helium ions in Hyperion.
    Fuchs H; Alber M; Schreiner T; Georg D
    Med Phys; 2015 Sep; 42(9):5157-66. PubMed ID: 26328967
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Application of lung substitute material as ripple filter for multi-ion therapy with helium-, carbon-, oxygen-, and neon-ion beams.
    Inaniwa T; Abe Y; Suzuki M; Lee SH; Mizushima K; Nakaji T; Sakata D; Sato S; Iwata Y; Kanematsu N; Shirai T
    Phys Med Biol; 2021 Feb; 66(5):. PubMed ID: 33477116
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Dose and Radiation Quality Optimized Heavy-Ion Radiotherapy].
    Inaniwa T
    Igaku Butsuri; 2020; 40(1):23-27. PubMed ID: 32238679
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Proton and helium ion radiotherapy for meningioma tumors: a Monte Carlo-based treatment planning comparison.
    Tessonnier T; Mairani A; Chen W; Sala P; Cerutti F; Ferrari A; Haberer T; Debus J; Parodi K
    Radiat Oncol; 2018 Jan; 13(1):2. PubMed ID: 29316969
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Relative biological effectiveness of single and split helium ion doses in the rat spinal cord increases strongly with linear energy transfer.
    Hintz L; Glowa C; Saager M; Euler-Lange R; Peschke P; Brons S; Grün R; Scholz M; Mein S; Mairani A; Debus J; Karger CP
    Radiother Oncol; 2022 May; 170():224-230. PubMed ID: 35367526
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lateral variations of radiobiological properties of therapeutic fields of
    Dewey S; Burigo L; Pshenichnov I; Mishustin I; Bleicher M
    Phys Med Biol; 2017 Jun; 62(14):5884-5907. PubMed ID: 28557800
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biological dose optimization incorporating intra-tumoural cellular radiosensitivity heterogeneity in ion-beam therapy treatment planning.
    Inaniwa T; Kanematsu N; Koto M
    Phys Med Biol; 2024 May; 69(11):. PubMed ID: 38636504
    [No Abstract]   [Full Text] [Related]  

  • 19. Estimating the biological effects of helium, carbon, oxygen, and neon ion beams using 3D silicon microdosimeters.
    Lee SH; Mizushima K; Kohno R; Iwata Y; Yonai S; Shirai T; Pan VA; Bolst D; Tran LT; Rosenfeld AB; Suzuki M; Inaniwa T
    Phys Med Biol; 2021 Feb; 66(4):045017. PubMed ID: 33361575
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Commissioning of Helium Ion Therapy and the First Patient Treatment With Active Beam Delivery.
    Tessonnier T; Ecker S; Besuglow J; Naumann J; Mein S; Longarino FK; Ellerbrock M; Ackermann B; Winter M; Brons S; Qubala A; Haberer T; Debus J; Jäkel O; Mairani A
    Int J Radiat Oncol Biol Phys; 2023 Jul; 116(4):935-948. PubMed ID: 36681200
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.