150 related articles for article (PubMed ID: 35722426)
1. Performance evaluation of routine blood and C-reactive protein analysis using Mindray BC-7500 CRP auto hematology analyzer.
Lin Z; Lin Q; Yu P; Chen Z; Lin H; Zhu B; Wang M; Cao Y
Ann Transl Med; 2022 May; 10(10):588. PubMed ID: 35722426
[TBL] [Abstract][Full Text] [Related]
2. Detection of nucleated red blood cells using the Mindray BC-6800Plus hematology analyzer: a clinical performance evaluation.
Wang N; Jiang J; Wang J; He Y; Wen N; Liu Y; Wang Y; Li H; Shi P
Ann Palliat Med; 2021 Aug; 10(8):8808-8817. PubMed ID: 34488369
[TBL] [Abstract][Full Text] [Related]
3. The possibility of automatic capillary blood testing in routine blood tests: an evaluation of the automatic mode of the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood testing.
He J; Zhang G; Wang Y; Yang H; Dai Q; Guo S; Mai J
Cardiovasc Diagn Ther; 2023 Jun; 13(3):465-473. PubMed ID: 37405010
[TBL] [Abstract][Full Text] [Related]
4. Evaluation and comparison of the new Mindray BC-6200 hematology analyzer with ADVIA 2120i.
Kulik K; KwiecieĊ I; CheĊstowska B; Rutkowska E; Rzepecki P
Int J Lab Hematol; 2021 Jun; 43(3):395-402. PubMed ID: 33270987
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of Mindray BC-3600 hematology analyzer in a university hospital.
Shu G; Lu H; Du H; Shi J; Wu G
Int J Lab Hematol; 2013 Feb; 35(1):61-9. PubMed ID: 22925195
[TBL] [Abstract][Full Text] [Related]
6. Clinical performance evaluation of the new hematology analyzer Mindray BC-6000.
Shen Y; Cao J; Zhou Z; Wang Y; Shen Y; He J
Int J Lab Hematol; 2019 Oct; 41(5):622-634. PubMed ID: 31286670
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of humoral pattern detection performance of Mindray BC-6000PLUS blood analyzer based on WS/T 662-2020.
Long Y; Liu J; Chen F; Luo Y; Zhao C; Wei J; Chen C; Lin D
Ann Palliat Med; 2021 Jun; 10(6):6446-6454. PubMed ID: 34154351
[TBL] [Abstract][Full Text] [Related]
8. Automated nucleated red blood cell count using the Mindray BC-6800 hematology analyzer.
Houyhongthong V; Nunphuak W; Sripatumtong C; Parnsamut C; Ketloy C
Int J Lab Hematol; 2018 Oct; 40(5):611-616. PubMed ID: 29927038
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of Mindray BC-5000 hematology analyzer: a new miniature 5-part WBC differential instrument.
Xiang D; Yue J; Lan Y; Sha C; Ren S; Li Y; Li M; Wang C
Int J Lab Hematol; 2015 Oct; 37(5):597-605. PubMed ID: 25944368
[TBL] [Abstract][Full Text] [Related]
10. Performance evaluation of optical platelet counting of BC-6000Plus automated hematology analyzer.
Hu X; Tang Y; Li M; Fu C; Deng Z; Tang W; Zhou H; Chen Y; Li Y
Ann Transl Med; 2021 Mar; 9(6):508. PubMed ID: 33850905
[TBL] [Abstract][Full Text] [Related]
11. Performance evaluation of the new platelet measurement channel on the BC-6800 Plus automated hematology analyzer.
Guo P; Cai Q; Mao M; Lin H; Chen L; Wu F; Wang J
Int J Lab Hematol; 2022 Apr; 44(2):281-287. PubMed ID: 34873856
[TBL] [Abstract][Full Text] [Related]
12. Performance Evaluation of the Mindray BC 6800 Hematology Analyzer and Flag Comparison with the XE-2100 and Manual Microscopy.
Xiang D; Yue J; Sha C; Ren S; Li M; Wang C
Clin Lab; 2019 Apr; 65(4):. PubMed ID: 30969092
[TBL] [Abstract][Full Text] [Related]
13. Consistency Analysis of 3 Detection Systems for Measuring Serum C-Reactive Protein.
Chen X; Huang C; Zhong W; Qi S; Huang T; Yang Z
Med Sci Monit; 2022 May; 28():e935171. PubMed ID: 35538647
[TBL] [Abstract][Full Text] [Related]
14. Immunoturbidimetric Assay for Determination of Peripheral Blood C Reactive Protein on the Pentra MS CRP Hematology Analyzer.
Xiang D; Yue J; Liu P; Sun J; Ren S; Sha C; Wang C
Clin Lab; 2019 Jun; 65(6):. PubMed ID: 31232024
[TBL] [Abstract][Full Text] [Related]
15. Clinical performance evaluation of serum amyloid A module of Mindray BC-7500CS automated hematology analyzer.
Dai J; Zhang X; Zhou J; Pan W; Yu F
Transl Pediatr; 2023 Jan; 12(1):20-30. PubMed ID: 36798927
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of automated capillary complete blood counts for routine clinical decision making in a large cohort of hematological patients, using Mindray BC-3000 Plus Auto and Sysmex XE-5000 hematology analyzers.
Oudatzis G; Tsagarakis NJ; Paterakis G; Vasileiou P; Xenou E; Maraki P; Pangrati T; Angelopoulou MK; Vassilakopoulos TP; Konstantopoulos K
Int J Lab Hematol; 2020 Oct; 42(5):565-572. PubMed ID: 32426940
[TBL] [Abstract][Full Text] [Related]
17. Performance evaluation of the new hematology analyzer Sysmex XN-series.
Seo JY; Lee ST; Kim SH
Int J Lab Hematol; 2015 Apr; 37(2):155-64. PubMed ID: 24815300
[TBL] [Abstract][Full Text] [Related]
18. Precision and accuracy of the Mindray BC-5000Vet hematology analyzer for canine and feline blood.
Thongsahuan S; Fonghoi L; Kaewfai S; Srinoun K
Vet Clin Pathol; 2020 Jun; 49(2):207-216. PubMed ID: 32524640
[TBL] [Abstract][Full Text] [Related]
19. Integration of an MC-80 Digital Image Analyzer With an Automated BC-6800Plus Hematology Analyzer Enables Accurate Platelet Counting in Samples With EDTA-Induced Pseudothrombocytopenia.
So MK; Huh J; Kim S; Park S
Ann Lab Med; 2024 Apr; ():. PubMed ID: 38572537
[TBL] [Abstract][Full Text] [Related]
20. Performance evaluation of the new measurement channels on the automated Sysmex XN-9000 hematology analyzer.
Schapkaitz E; Raburabu S
Clin Biochem; 2018 Mar; 53():132-138. PubMed ID: 29374555
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]