2. [Automatic measurement of intraocular pressure with an electronic sensor tonometer]. Draeger J; Hechler B; Levedag S; Wirt H Klin Monbl Augenheilkd; 1987 Jun; 190(6):539-41. PubMed ID: 3626414 [TBL] [Abstract][Full Text] [Related]
3. Corneal hysteresis and intraocular pressure measurement in children using the reichert ocular response analyzer. Kirwan C; O'Keefe M; Lanigan B Am J Ophthalmol; 2006 Dec; 142(6):990-2. PubMed ID: 17157583 [TBL] [Abstract][Full Text] [Related]
4. [Intraocular pressure difference in Goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01"PRA" in glaucoma patients]. Schlote T; Landenberger H Klin Monbl Augenheilkd; 2005 Feb; 222(2):123-31. PubMed ID: 15719316 [TBL] [Abstract][Full Text] [Related]
7. Effect of central corneal thickness and corneal hysteresis on tonometry as measured by dynamic contour tonometry, ocular response analyzer, and Goldmann tonometry in glaucomatous eyes. Hager A; Loge K; Schroeder B; Füllhas MO; Wiegand W J Glaucoma; 2008 Aug; 17(5):361-5. PubMed ID: 18703945 [TBL] [Abstract][Full Text] [Related]
8. [Oculopression tonometry (OPT): a new tonographic procedure in the diagnosis of glaucoma]. Ulrich WD; Ulrich C; Neunhöffer E; Fuhrmann P Klin Monbl Augenheilkd; 1987 Feb; 190(2):109-13. PubMed ID: 3573661 [TBL] [Abstract][Full Text] [Related]
9. Comparison of Goldmann applanation and applanation resonance tonometry in a biomicroscope-based in vitro porcine eye model. Hallberg P; Santala K; Lindén C; Lindahl OA; Eklund A J Med Eng Technol; 2006; 30(6):345-52. PubMed ID: 17060162 [TBL] [Abstract][Full Text] [Related]
10. Measuring intraocular pressure-adjustments for corneal thickness and new technologies. Herndon LW Curr Opin Ophthalmol; 2006 Apr; 17(2):115-9. PubMed ID: 16552245 [TBL] [Abstract][Full Text] [Related]
11. [The role of pachymetry in routine glaucoma diagnosis]. von Eicken J; Kohlhaas M; Stodtmeister R; Höh H Klin Monbl Augenheilkd; 2006 Feb; 223(2):117-30. PubMed ID: 16485223 [TBL] [Abstract][Full Text] [Related]
12. [Intraocular pressure measurements with the Proview self-tonometer in comparison of Goldmann applanation tonometry in healthy and glaucomatous eyes]. Meyer MW; Yevelenko V; Hoy L; Meyer A; Erb C Klin Monbl Augenheilkd; 2006 Nov; 223(11):899-903. PubMed ID: 17131250 [TBL] [Abstract][Full Text] [Related]
20. [Ocular pressure tonometry--value as a procedure in the diagnosis of glaucoma in comparison with classical tonography]. Wetzel W; Papst N Fortschr Ophthalmol; 1988; 85(4):363-5. PubMed ID: 3220352 [No Abstract] [Full Text] [Related] [Next] [New Search]