145 related articles for article (PubMed ID: 35740797)
1. Does Focal Osteolysis in a PRECICE Stryde Intramedullary Lengthening Nail Resolve after Explantation?
Sax OC; Hlukha LP; Kowalewski KA; Herzenberg JE; McClure PK
Children (Basel); 2022 Jun; 9(6):. PubMed ID: 35740797
[TBL] [Abstract][Full Text] [Related]
2. A clinical and radiological matched-pair analysis of patients treated with the PRECICE and STRYDE magnetically driven motorized intramedullary lengthening nails.
Vogt B; Rupp C; Gosheger G; Eveslage M; Laufer A; Toporowski G; Roedl R; Frommer A
Bone Joint J; 2023 Jan; 105-B(1):88-96. PubMed ID: 36587248
[TBL] [Abstract][Full Text] [Related]
3. Focal osteolysis at the junctions of a modular stainless-steel femoral intramedullary nail.
Jones DM; Marsh JL; Nepola JV; Jacobs JJ; Skipor AK; Urban RM; Gilbert JL; Buckwalter JA
J Bone Joint Surg Am; 2001 Apr; 83(4):537-48. PubMed ID: 11315782
[TBL] [Abstract][Full Text] [Related]
4. Radiographs of 366 removed limb-lengthening nails reveal differences in bone abnormalities between different nail types.
Iobst CA; Frost MW; Rölfing JD; Rahbek O; Bafor A; Duncan M; Kold S
Bone Joint J; 2021 Nov; 103-B(11):1731-1735. PubMed ID: 34414785
[TBL] [Abstract][Full Text] [Related]
5. Precice Stryde® Magnetic Internal Lengthening Nail does not Impair Bone Healing Despite Radiographic and Clinical Symptoms.
Reif TJ; Geffner A; Hoellwarth JS; Fragomen AT; Rozbruch SR
Strategies Trauma Limb Reconstr; 2023; 18(2):94-99. PubMed ID: 37942435
[TBL] [Abstract][Full Text] [Related]
6. Early results from a single centre's experience with the STRYDE nail : a cause for concern?
Iliadis AD; Wright J; Stoddart MT; Goodier WD; Calder P
Bone Joint J; 2021 Jun; 103-B(6):1168-1172. PubMed ID: 34058877
[TBL] [Abstract][Full Text] [Related]
7. Pain, osteolysis, and periosteal reaction are associated with the STRYDE limb lengthening nail: a nationwide cross-sectional study.
Rölfing JD; Kold S; Nygaard T; Mikuzis M; Brix M; Faergemann C; Gottliebsen M; Davidsen M; Petruskevicius J; Olesen UK
Acta Orthop; 2021 Aug; 92(4):479-484. PubMed ID: 33757381
[TBL] [Abstract][Full Text] [Related]
8. No osteolysis at the telescopic junction of 128 FITBONE lengthening nails.
Leblanc C; Rölfing JD; Langlais T; Sales de Gauzy J; Accadbled F
Orthop Traumatol Surg Res; 2023 May; 109(3):103501. PubMed ID: 36470369
[TBL] [Abstract][Full Text] [Related]
9. Focal osteolysis and corrosion at the junction of Precice Stryde intramedullary lengthening device : preliminary clinical, radiological, and metallurgic analysis of 57 lengthened segments.
Frommer A; Roedl R; Gosheger G; Hasselmann J; Fuest C; Toporowski G; Laufer A; Tretow H; Schulze M; Vogt B
Bone Joint Res; 2021 Jul; 10(7):425-436. PubMed ID: 34269599
[TBL] [Abstract][Full Text] [Related]
10. Early Weight-bearing Accelerates Regenerate Bone Mineralisation: A Pilot Study Comparing Two Post-operative Weight-bearing Protocols Following Intramedullary Limb Lengthening Using the Pixel Value Ratio.
Bafor A; Duncan ME; Iobst CA
Strategies Trauma Limb Reconstr; 2022; 17(3):148-152. PubMed ID: 36756288
[TBL] [Abstract][Full Text] [Related]
11. The STRYDE limb lengthening nail is susceptible to mechanically assisted crevice corrosion: an analysis of 23 retrieved implants.
Jellesen MS; Lomholt TN; Hansen RQ; Mathiesen T; Gundlach C; Kold S; Nygaard T; Mikuzis M; Olesen UK; Rölfing JD
Acta Orthop; 2021 Oct; 92(5):621-627. PubMed ID: 34102950
[TBL] [Abstract][Full Text] [Related]
12. Biopsy Proven Focal Osteolysis in a Stainless-Steel Limb-Lengthening Device: A Report of Three Cases.
Sax OC; Molavi DW; Herzenberg JE; Standard SC; McClure PK
J Am Acad Orthop Surg Glob Res Rev; 2021 Oct; 5(10):. PubMed ID: 34644273
[TBL] [Abstract][Full Text] [Related]
13. Removal of a Broken Stainless-Steel Intramedullary Lengthening Stryde Nail: A Case Report and Review of the Literature.
Abalkhail TB; McClure PK
JBJS Case Connect; 2021 Dec; 11(4):. PubMed ID: 34937043
[TBL] [Abstract][Full Text] [Related]
14. Complications in Elective Removal of 271 Bone Lengthening Nails (FITBONE, PRECICE and STRYDE).
Frost MW; Kold S; Rahbek O; Bafor A; Duncan M; Iobst CA
Strategies Trauma Limb Reconstr; 2021; 16(2):110-115. PubMed ID: 34804227
[TBL] [Abstract][Full Text] [Related]
15. Corrosion of a Fassier-Duval Telescopic Nail Causing Pain and Osteolysis: A Case Report.
Ngo D; Todd M; Accadbled F; Foster B; Jellesen MS; Rölfing JD; Rawat J
JBJS Case Connect; 2024 Jan; 14(1):. PubMed ID: 38181104
[TBL] [Abstract][Full Text] [Related]
16. Pediatric Lower Limb Lengthening Using the PRECICE Nail: Our Experience With 50 Cases.
Iliadis AD; Palloni V; Wright J; Goodier D; Calder P
J Pediatr Orthop; 2021 Jan; 41(1):e44-e49. PubMed ID: 32947442
[TBL] [Abstract][Full Text] [Related]
17. Removal of broken PRECICE Stryde intramedullary lengthening nails.
Rölfing JD; Bünger M; Petruskevicius J; Abood AA
Orthop Traumatol Surg Res; 2021 Dec; 107(8):102958. PubMed ID: 33965599
[TBL] [Abstract][Full Text] [Related]
18. Lower limb lengthening over an intramedullary nail: a long-term follow-up study of 28 cases.
Farsetti P; De Maio F; Potenza V; Efremov K; Marsiolo M; Caterini A; Ippolito E
J Orthop Traumatol; 2019 Sep; 20(1):30. PubMed ID: 31506759
[TBL] [Abstract][Full Text] [Related]
19. Extracorporal noninvasive acute retraction of STRYDE
Schiedel F
Arch Orthop Trauma Surg; 2021 Jun; 141(6):899-905. PubMed ID: 32458076
[TBL] [Abstract][Full Text] [Related]
20. Regenerate Deformity with the Precice Tibial Nail.
Wright SE; Goodier WD; Calder P
Strategies Trauma Limb Reconstr; 2020; 15(2):98-105. PubMed ID: 33505526
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]