These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

200 related articles for article (PubMed ID: 35762071)

  • 1. First clinical experience of high-power ablation of atrial fibrillation with a novel contact force-sensing gold-tip catheter.
    Parwani AS; Jayanata A; Kraft R; Lacour P; Blaschke F; Pieske B; Boldt LH
    Cardiol J; 2022; 29(5):759-765. PubMed ID: 35762071
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Feasibility and safety of high-power ablation of atrial fibrillation with contact force-sensing catheter: The lesion size index-guided ablation.
    Parwani AS; Hohendanner F; Kluck A; Blaschke F; Pieske B; Boldt LH
    Adv Clin Exp Med; 2022 Jul; 31(7):715-721. PubMed ID: 35302302
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Efficacy and safety of the GOLD FORCE multicentre randomized clinical trial: multielectrode phased radiofrequency vs. irrigated radiofrequency single-tip catheter with contact force ablation for treatment of symptomatic paroxysmal atrial fibrillation.
    Wintgens LIS; Klaver MN; Maarse M; Spitzer SG; Langbein A; Swaans MJ; Van Dijk VF; Balt JC; Wijffels MCEF; Tijssen JGP; Elvan A; Boersma LVA
    Europace; 2021 Dec; 23(12):1931-1938. PubMed ID: 34279627
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Atrial fibrillation ablation using very short duration 50 W ablations and contact force sensing catheters.
    Winkle RA; Moskovitz R; Hardwin Mead R; Engel G; Kong MH; Fleming W; Salcedo J; Patrawala RA; Tranter JH; Shai I
    J Interv Card Electrophysiol; 2018 Jun; 52(1):1-8. PubMed ID: 29460232
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial.
    Natale A; Reddy VY; Monir G; Wilber DJ; Lindsay BD; McElderry HT; Kantipudi C; Mansour MC; Melby DP; Packer DL; Nakagawa H; Zhang B; Stagg RB; Boo LM; Marchlinski FE
    J Am Coll Cardiol; 2014 Aug; 64(7):647-56. PubMed ID: 25125294
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Lattice-Tip Focal Ablation Catheter That Toggles Between Radiofrequency and Pulsed Field Energy to Treat Atrial Fibrillation: A First-in-Human Trial.
    Reddy VY; Anter E; Rackauskas G; Peichl P; Koruth JS; Petru J; Funasako M; Minami K; Natale A; Jais P; Nakagawa H; Marinskis G; Aidietis A; Kautzner J; Neuzil P
    Circ Arrhythm Electrophysiol; 2020 Jun; 13(6):e008718. PubMed ID: 32383391
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mechanisms of pulmonary vein reconnection after radiofrequency ablation of atrial fibrillation: the deterministic role of contact force and interlesion distance.
    Park CI; Lehrmann H; Keyl C; Weber R; Schiebeling J; Allgeier J; Schurr P; Shah A; Neumann FJ; Arentz T; Jadidi AS
    J Cardiovasc Electrophysiol; 2014 Jul; 25(7):701-8. PubMed ID: 24575734
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters.
    Reichlin T; Knecht S; Lane C; Kühne M; Nof E; Chopra N; Tadros TM; Reddy VY; Schaer B; John RM; Osswald S; Stevenson WG; Sticherling C; Michaud GF
    Heart Rhythm; 2014 Feb; 11(2):194-201. PubMed ID: 24177370
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The best of two worlds? Pulmonary vein isolation using a novel radiofrequency ablation catheter incorporating contact force sensing technology and 56-hole porous tip irrigation.
    Maurer T; Rottner L; Makimoto H; Reissmann B; Heeger CH; Lemes C; Fink T; Riedl J; Santoro F; Wohlmuth P; Volkmer M; Mathew S; Metzner A; Ouyang F; Kuck KH; Sohns C
    Clin Res Cardiol; 2018 Nov; 107(11):1003-1012. PubMed ID: 29740700
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Safety aspects of very high power very short duration atrial fibrillation ablation using a modified radiofrequency RF-generator: Single-center experience.
    Mueller J; Halbfass P; Sonne K; Nentwich K; Ene E; Berkovitz A; Lehmkuhl L; Barth S; Simu GR; Waechter C; Behnes M; Deneke T
    J Cardiovasc Electrophysiol; 2022 May; 33(5):920-927. PubMed ID: 35233883
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Safety and long-term effectiveness of paroxysmal atrial fibrillation ablation with a contact force-sensing catheter: real-world experience from a prospective, multicentre observational cohort registry.
    De Potter T; Van Herendael H; Balasubramaniam R; Wright M; Agarwal SC; Sanders P; Khaykin Y; Latcu DG; Maury P; Pani A; Hayes J; Kalman J; Nery P; Duncan E
    Europace; 2018 Nov; 20(FI_3):f410-f418. PubMed ID: 29315382
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pulmonary Vein Isolation With Very High Power, Short Duration, Temperature-Controlled Lesions: The QDOT-FAST Trial.
    Reddy VY; Grimaldi M; De Potter T; Vijgen JM; Bulava A; Duytschaever MF; Martinek M; Natale A; Knecht S; Neuzil P; Pürerfellner H
    JACC Clin Electrophysiol; 2019 Jul; 5(7):778-786. PubMed ID: 31320006
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Temperature-controlled high-power short-duration ablation with 90 W for 4 s: outcome, safety, biophysical characteristics and cranial MRI findings in patients undergoing pulmonary vein isolation.
    Kottmaier M; Förschner L; Harfoush N; Bourier F; Mayr S; Reents T; Klupp E; Zimmer C; Hadamitzki M; Hendrick E; Krafft H; Lengauer S; Maurer S; Telishevska M; Popa M; Lennerz C; Hessling G; Deisenhofer I
    J Interv Card Electrophysiol; 2022 Nov; 65(2):491-497. PubMed ID: 35748975
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Catheter-tissue contact force determines atrial electrogram characteristics before and lesion efficacy after antral pulmonary vein isolation in humans.
    Kumar S; Chan M; Lee J; Wong MC; Yudi M; Morton JB; Spence SJ; Halloran K; Kistler PM; Kalman JM
    J Cardiovasc Electrophysiol; 2014 Feb; 25(2):122-9. PubMed ID: 24102727
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Newer generation cryoballoon vs. contact force-sensing radiofrequency ablation catheter in the ablation of paroxysmal atrial fibrillation.
    Ali AN; Riad O; Tawfik M; Opel A; Wong T
    Herzschrittmacherther Elektrophysiol; 2021 Jun; 32(2):236-243. PubMed ID: 33999265
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Catheter ablation of atrial fibrillation using ablation index-guided high-power technique: Frankfurt AI high-power 15-month follow-up.
    Chen S; Schmidt B; Bordignon S; Tohoku S; Urban VC; Schulte-Hahn B; Chun KRJ
    J Cardiovasc Electrophysiol; 2021 Mar; 32(3):616-624. PubMed ID: 33484215
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Magnetically guided irrigated gold-tip catheter ablation of persistent atrial fibrillation--techniques, procedural parameters and outcome.
    Muntean B; Gutleben KJ; Heintze J; Vogt J; Horstkotte D; Nölker G
    J Interv Card Electrophysiol; 2012 Nov; 35(2):163-71. PubMed ID: 22622666
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A mesh-type flexible tip catheter vs a contact force catheter for catheter ablation of atrial fibrillation: A prospective nonrandomized 1:1 matched study.
    Pak HN; Park JW; Yang SY; Yu HT; Uhm JS; Joung B; Lee MH; Kim TH
    J Cardiovasc Electrophysiol; 2020 Jun; 31(6):1279-1288. PubMed ID: 32270578
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Catheter-tissue contact force for pulmonary veins isolation: a pilot multicentre study on effect on procedure and fluoroscopy time.
    Stabile G; Solimene F; Calò L; Anselmino M; Castro A; Pratola C; Golia P; Bottoni N; Grandinetti G; De Simone A; De Ponti R; Dottori S; Bertaglia E
    Europace; 2014 Mar; 16(3):335-40. PubMed ID: 24337158
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy and safety of novel temperature-controlled radiofrequency ablation system during pulmonary vein isolation in patients with paroxysmal atrial fibrillation: TRAC-AF study.
    Starek Z; Lehar F; Jez J; Pesl M; Neuzil P; Sediva L; Petru J; Dujka L; Funasako M; Kautzner J; Peichl P; Aldhoon B; Albenque JP; Combes S; Boveda S; Dukkipati SR; Reddy VY
    J Interv Card Electrophysiol; 2022 Aug; 64(2):375-381. PubMed ID: 34089431
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.