BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

232 related articles for article (PubMed ID: 35763217)

  • 1. A Comparison of Finger Pulse Oximeter and SET-Based Neonatal Pulse Oximeter in Neonates in Terms of SpO
    Khamkar AM; Pote PD; Jose GE
    Indian J Pediatr; 2022 Nov; 89(11):1120-1122. PubMed ID: 35763217
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effects of motion on the performance of pulse oximeters in volunteers (revised publication).
    Barker SJ; Shah NK
    Anesthesiology; 1997 Jan; 86(1):101-8. PubMed ID: 9009945
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR; Bickler PE; Mannheimer PD
    Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A prototype device for standardized calibration of pulse oximeters II.
    Hornberger Ch; Knoop P; Matz H; Dörries F; Konecny E; Gehring H; Otten J; Bonk R; Frankenberger H; Wouters P; Gil-Rodriguez J; Ponz L; Avgerinos J; Karoutis A; Ikiades A; Weininger S
    J Clin Monit Comput; 2002; 17(3-4):203-9. PubMed ID: 12455737
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reliability of conventional and new pulse oximetry in neonatal patients.
    Hay WW; Rodden DJ; Collins SM; Melara DL; Hale KA; Fashaw LM
    J Perinatol; 2002; 22(5):360-6. PubMed ID: 12082469
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of heart rate and oxygen saturation measurements from Masimo and Nellcor pulse oximeters in newly born term infants.
    Dawson JA; Saraswat A; Simionato L; Thio M; Kamlin CO; Owen LS; Schmölzer GM; Davis PG
    Acta Paediatr; 2013 Oct; 102(10):955-60. PubMed ID: 23800004
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Accuracy of Readily Available Consumer-Grade Oxygen Saturation Monitors in Pediatric Patients.
    Kovesi T; Saban J; Haddad JF; Reddy D; Webster R; Udupa S
    Respir Care; 2024 Mar; 69(4):387-394. PubMed ID: 38164568
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Perioperative comparison of the agreement between a portable fingertip pulse oximeter v. a conventional bedside pulse oximeter in adult patients (COMFORT trial).
    Smith RN; Hofmeyr R
    S Afr Med J; 2019 Feb; 109(3):154-158. PubMed ID: 30834870
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reliability and Validity of a Smartphone-Paired Pulse Oximeter for Screening of Critical Congenital Heart Defects in Newborns.
    Huizing MJ; Villamor-Martínez E; Chavagne IA; Vanagt WY; Spaanderman MAE; Villamor E
    Neonatology; 2017; 112(4):324-329. PubMed ID: 28768288
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical use of new-generation pulse oximeters in the neonatal intensive care unit.
    Workie FA; Rais-Bahrami K; Short BL
    Am J Perinatol; 2005 Oct; 22(7):357-60. PubMed ID: 16215921
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of pulse oximeters in detecting hypoxemia in patients with chronic thromboembolic pulmonary hypertension.
    Kohyama T; Moriyama K; Kanai R; Kotani M; Uzawa K; Satoh T; Yorozu T
    PLoS One; 2015; 10(5):e0126979. PubMed ID: 25978517
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy of Wireless Pulse Oximeter on Preterm or <2.5 kg Infants.
    Thomas M; Day H; Petersen B; Marchant T; Jones C; Singh Y; Chan B
    Am J Perinatol; 2024 May; 41(S 01):e1606-e1612. PubMed ID: 37072015
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accuracy of two pulse oximeters at low arterial hemoglobin-oxygen saturation.
    Carter BG; Carlin JB; Tibballs J; Mead H; Hochmann M; Osborne A
    Crit Care Med; 1998 Jun; 26(6):1128-33. PubMed ID: 9635666
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of pulse oximetry to monitor venous saturation during extracorporeal life support.
    Odell RM; Doran RM; Erickson RC; Zeilinger TC; Coyle MG
    Crit Care Med; 1994 Apr; 22(4):626-32. PubMed ID: 8143472
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of Multiple Pulse Oximeters in Stable Critically Ill Patients.
    Blanchet MA; Mercier G; Delobel A; Nayet E; Bouchard PA; Simard S; L'Her E; Branson RD; Lellouche F
    Respir Care; 2023 May; 68(5):565-574. PubMed ID: 36596654
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Inpatient comparison of wireless and wired pulse oximetry in neonates.
    Harrell MD; Dobson NR; Olsen C; Ahmed A; Hunt CE
    J Neonatal Perinatal Med; 2022; 15(2):283-289. PubMed ID: 35275564
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of motion on the performance of pulse oximeters in volunteers.
    Barker SJ; Shah NK
    Anesthesiology; 1996 Oct; 85(4):774-81. PubMed ID: 8873547
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance of five pulse oximeters to detect hypoxaemia as an indicator of severe illness in children under five by frontline health workers in low resource settings - A prospective, multicentre, single-blinded, trial in Cambodia, Ethiopia, South Sudan, and Uganda.
    Baker K; Petzold M; Mucunguzi A; Wharton-Smith A; Dantzer E; Habte T; Matata L; Nanyumba D; Okwir M; Posada M; Sebsibe A; Nicholson J; Marasciulo M; Izadnegahdar R; Alfvén T; Källander K
    EClinicalMedicine; 2021 Aug; 38():101040. PubMed ID: 34368660
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of two new generation pulse oximeters with arterial oxygen saturation in critically ill children.
    Jose B; Lodha R; Kabra SK
    Indian J Pediatr; 2014 Dec; 81(12):1297-301. PubMed ID: 24627281
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance of Two Different Pulse Oximeters in Neonatal Transition.
    Jeyapal S; Kommu PP; Manikandan M; Krishnan L
    Indian J Pediatr; 2017 Jan; 84(1):7-12. PubMed ID: 27538981
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.