177 related articles for article (PubMed ID: 35766667)
1. A deep look into the rib cage compression technique in mechanically ventilated patients: a narrative review.
Jalil Y; Damiani LF; Basoalto R; Bachmman MC; Bruhn A
Rev Bras Ter Intensiva; 2022; 34(1):176-184. PubMed ID: 35766667
[TBL] [Abstract][Full Text] [Related]
2. Effects of manual rib cage compressions on expiratory flow and mucus clearance during mechanical ventilation.
Martí JD; Li Bassi G; Rigol M; Saucedo L; Ranzani OT; Esperatti M; Luque N; Ferrer M; Vilaro J; Kolobow T; Torres A
Crit Care Med; 2013 Mar; 41(3):850-6. PubMed ID: 23314585
[TBL] [Abstract][Full Text] [Related]
3. Effects of Manual Rib Cage Compressions on Mucus Clearance in Mechanically Ventilated Pigs.
Ouchi A; Sakuramoto H; Unoki T; Yoshino Y; Hosino H; Koyama Y; Enomoto Y; Shimojo N; Mizutani T; Inoue Y
Respir Care; 2020 Aug; 65(8):1135-1140. PubMed ID: 32047123
[TBL] [Abstract][Full Text] [Related]
4. Expiratory rib cage compression in mechanically ventilated adults: systematic review with meta-analysis.
Borges LF; Saraiva MS; Saraiva MAS; Macagnan FE; Kessler A
Rev Bras Ter Intensiva; 2017; 29(1):96-104. PubMed ID: 28444078
[TBL] [Abstract][Full Text] [Related]
5. Effects of expiratory rib cage compression combined with endotracheal suctioning on gas exchange in mechanically ventilated rabbits with induced atelectasis.
Unoki T; Mizutani T; Toyooka H
Respir Care; 2004 Aug; 49(8):896-901. PubMed ID: 15271228
[TBL] [Abstract][Full Text] [Related]
6. Effects of expiratory rib cage compression and/or prone position on oxygenation and ventilation in mechanically ventilated rabbits with induced atelectasis.
Unoki T; Mizutani T; Toyooka H
Respir Care; 2003 Aug; 48(8):754-62. PubMed ID: 12890295
[TBL] [Abstract][Full Text] [Related]
7. Effects of expiratory rib-cage compression on oxygenation, ventilation, and airway-secretion removal in patients receiving mechanical ventilation.
Unoki T; Kawasaki Y; Mizutani T; Fujino Y; Yanagisawa Y; Ishimatsu S; Tamura F; Toyooka H
Respir Care; 2005 Nov; 50(11):1430-7. PubMed ID: 16253149
[TBL] [Abstract][Full Text] [Related]
8. The effect of expiratory rib cage compression before endotracheal suctioning on the vital signs in patients under mechanical ventilation.
Bousarri MP; Shirvani Y; Agha-Hassan-Kashani S; Nasab NM
Iran J Nurs Midwifery Res; 2014 May; 19(3):285-9. PubMed ID: 24949068
[TBL] [Abstract][Full Text] [Related]
9. Expiratory rib cage Compression in mechanically ventilated subjects: a randomized crossover trial [corrected].
Guimarães FS; Lopes AJ; Constantino SS; Lima JC; Canuto P; de Menezes SL
Respir Care; 2014 May; 59(5):678-85. PubMed ID: 24106324
[TBL] [Abstract][Full Text] [Related]
10. Cardiorespiratory consequences of expiratory chest wall compression during mechanical ventilation and severe hyperinflation.
Van der Touw T; Tully A; Amis TC; Brancatisano A; Rynn M; Mudaliar Y; Engel LA
Crit Care Med; 1993 Dec; 21(12):1908-14. PubMed ID: 8252897
[TBL] [Abstract][Full Text] [Related]
11. Cardiorespiratory effects of manually compressing the rib cage during tidal expiration in mechanically ventilated patients recovering from acute severe asthma.
Van der Touw T; Mudaliar Y; Nayyar V
Crit Care Med; 1998 Aug; 26(8):1361-7. PubMed ID: 9710095
[TBL] [Abstract][Full Text] [Related]
12. Effects of ventilation mode and manual chest compression on flow bias during the positive end- and zero end-expiratory pressure manoeuvre in mechanically ventilated patients: a randomised crossover trial.
Amaral BLR; de Figueiredo AB; Lorena DM; Oliveira ACO; Carvalho NC; Volpe MS
Physiotherapy; 2020 Mar; 106():145-153. PubMed ID: 30979507
[TBL] [Abstract][Full Text] [Related]
13. The unique contribution of manual chest compression-vibrations to airflow during physiotherapy in sedated, fully ventilated children.
Gregson RK; Shannon H; Stocks J; Cole TJ; Peters MJ; Main E
Pediatr Crit Care Med; 2012 Mar; 13(2):e97-e102. PubMed ID: 21666530
[TBL] [Abstract][Full Text] [Related]
14. Effect of positioning and expiratory rib-cage compression on atelectasis in a patient who required prolonged mechanical ventilation: a case report.
Hosoe T; Tanaka T; Hamasaki H; Nonoyama K
J Med Case Rep; 2022 Jun; 16(1):265. PubMed ID: 35739590
[TBL] [Abstract][Full Text] [Related]
15. Changes in ventilation mechanics during expiratory rib cage compression in healthy males.
Mase K; Yamamoto K; Murakami S; Kihara K; Matsushita K; Nozoe M; Takashima S
J Phys Ther Sci; 2018 Jun; 30(6):820-824. PubMed ID: 29950772
[TBL] [Abstract][Full Text] [Related]
16. Comparison of changes in tidal volume associated with expiratory rib cage compression and expiratory abdominal compression in patients on prolonged mechanical ventilation.
Morino A; Shida M; Tanaka M; Sato K; Seko T; Ito S; Ogawa S; Takahashi N
J Phys Ther Sci; 2015 Jul; 27(7):2253-6. PubMed ID: 26311963
[TBL] [Abstract][Full Text] [Related]
17. Air Stacking: A Detailed Look Into Physiological Acute Effects on Cough Peak Flow and Chest Wall Volumes of Healthy Subjects.
Sarmento A; de Andrade AF; Lima ÍN; Aliverti A; de Freitas Fregonezi GA; Resqueti VR
Respir Care; 2017 Apr; 62(4):432-443. PubMed ID: 28196935
[TBL] [Abstract][Full Text] [Related]
18. Airway Clearance Techniques for Mechanically Ventilated Patients: Insights for Optimization.
Volpe MS; Guimarães FS; Morais CC
Respir Care; 2020 Aug; 65(8):1174-1188. PubMed ID: 32712584
[TBL] [Abstract][Full Text] [Related]
19. Effects of manual rib-cage compression versus PEEP-ZEEP maneuver on respiratory system compliance and oxygenation in patients receiving mechanical ventilation.
Santos FR; Schneider Júnior LC; Forgiarini Junior LA; Veronezi J
Rev Bras Ter Intensiva; 2009 Jun; 21(2):155-61. PubMed ID: 25303345
[TBL] [Abstract][Full Text] [Related]
20. Effects of manual chest compression on expiratory flow bias during the positive end-expiratory pressure-zero end-expiratory pressure maneuver in patients on mechanical ventilation.
Oliveira ACO; Lorena DM; Gomes LC; Amaral BLR; Volpe MS
J Bras Pneumol; 2019 Mar; 45(3):e20180058. PubMed ID: 30864618
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]