197 related articles for article (PubMed ID: 35769362)
21. [High performance of an implantable Holter monitor in the detection of concealed paroxysmal atrial fibrillation in patients with cryptogenic stroke and a suspected embolic mechanism].
Rojo-Martinez E; Sandín-Fuentes M; Calleja-Sanz AI; Cortijo-García E; García-Bermejo P; Ruiz-Piñero M; Rubio-Sanz J; Arenillas-Lara JF
Rev Neurol; 2013 Sep; 57(6):251-7. PubMed ID: 24008935
[TBL] [Abstract][Full Text] [Related]
22. Severity and Etiology of Incident Stroke in Patients Screened for Atrial Fibrillation vs Usual Care and the Impact of Prior Stroke: A Post Hoc Analysis of the LOOP Randomized Clinical Trial.
Diederichsen SZ; Frederiksen KS; Xing LY; Haugan KJ; Højberg S; Brandes A; Graff C; Olesen MS; Krieger D; Køber L; Svendsen JH
JAMA Neurol; 2022 Oct; 79(10):997-1004. PubMed ID: 36036546
[TBL] [Abstract][Full Text] [Related]
23. Detection of atrial fibrillation by implantable loop recorders following cryptogenic stroke: A retrospective study of predictive factors and outcomes.
Samaan S; Kohli U; Nazeer B; Stoute H; Zhao W; Szpunar SM; Azzo Z; Hassan S
J Electrocardiol; 2022; 71():54-58. PubMed ID: 35176666
[TBL] [Abstract][Full Text] [Related]
24. Atrial cardiopathy predicts detection of atrial fibrillation in embolic stroke of undetermined source: real-life data.
Silva AR; Pires C; Meira-Carvalho F; Santos M; Antunes NP; Alves JN; Ferreira C; Pinho J
Neurol Sci; 2022 Apr; 43(4):2383-2386. PubMed ID: 34708261
[TBL] [Abstract][Full Text] [Related]
25. Extended ECG monitoring with an implantable loop recorder in patients with cryptogenic stroke: time schedule, reasons for explantation and incidental findings (results from the TRACK-AF trial).
Bettin M; Dechering D; Kochhäuser S; Bode N; Eckardt L; Frommeyer G; Reinke F
Clin Res Cardiol; 2019 Mar; 108(3):309-314. PubMed ID: 30167809
[TBL] [Abstract][Full Text] [Related]
26. Predictors of Atrial Fibrillation Development in Patients With Embolic Stroke of Undetermined Source: An Analysis of the RE-SPECT ESUS Trial.
Bahit MC; Sacco RL; Easton JD; Meyerhoff J; Cronin L; Kleine E; Grauer C; Brueckmann M; Diener HC; Lopes RD; Brainin M; Lyrer P; Wachter R; Segura T; Granger CB;
Circulation; 2021 Nov; 144(22):1738-1746. PubMed ID: 34649459
[TBL] [Abstract][Full Text] [Related]
27. Stroke Recurrence in Embolic Stroke of Undetermined Source Without Atrial Fibrillation on Invasive Cardiac Monitoring.
Tan ESJ; de Leon J; Boey E; Chin HK; Ho KH; Aguirre S; Sim MG; Seow SC; Sharma VK; Kojodjojo P
Heart Lung Circ; 2023 Aug; 32(8):1000-1009. PubMed ID: 37291002
[TBL] [Abstract][Full Text] [Related]
28. Atrial Fibrillation Detected by Implantable Monitor in Embolic Stroke of Undetermined Source: A New Clinical Entity.
Snyman S; Seder E; David-Muller M; Klein V; Doche E; Suissa L; Deharo JC; Robinet-Borgomano E; Maille B
J Clin Med; 2022 Sep; 11(19):. PubMed ID: 36233608
[TBL] [Abstract][Full Text] [Related]
29. Left Ventricular Abnormality and Covert Atrial Fibrillation in Embolic Stroke of Undetermined Source.
Ikenouchi H; Koge J; Tanaka T; Yamaguchi E; Egashira S; Washida K; Nagase S; Kusano K; Toyoda K; Ihara M; Koga M
J Atheroscler Thromb; 2022 Jul; 29(7):1069-1075. PubMed ID: 34305083
[TBL] [Abstract][Full Text] [Related]
30. Covert atrial fibrillation and atrial high-rate episodes as a potential cause of embolic strokes of undetermined source: Their detection and possible management strategy.
Tomita H; Sasaki S; Hagii J; Metoki N
J Cardiol; 2018 Jul; 72(1):1-9. PubMed ID: 29609876
[TBL] [Abstract][Full Text] [Related]
31. Supraventricular Extrasystoles on Standard 12-lead Electrocardiogram Predict New Incident Atrial Fibrillation after Embolic Stroke of Undetermined Source: The AF-ESUS Study.
Ntaios G; Perlepe K; Lambrou D; Sirimarco G; Strambo D; Eskandari A; Karagkiozi E; Vemmou A; Koroboki E; Manios E; Makaritsis K; Michel P; Vemmos K
J Stroke Cerebrovasc Dis; 2020 Apr; 29(4):104626. PubMed ID: 31954605
[TBL] [Abstract][Full Text] [Related]
32. Detection of atrial fibrillation using an implantable loop recorder following cryptogenic stroke: implications for post-stroke electrocardiographic monitoring.
Milstein NS; Musat DL; Allred J; Seiler A; Pimienta J; Oliveros S; Bhatt AG; Preminger M; Sichrovsky T; Shaw RE; Mittal S
J Interv Card Electrophysiol; 2020 Jan; 57(1):141-147. PubMed ID: 31612300
[TBL] [Abstract][Full Text] [Related]
33. Long-Term Cardiac Monitoring After Embolic Stroke of Undetermined Source: Search Longer, Look Harder.
Sagris D; Harrison SL; Buckley BJR; Ntaios G; Lip GYH
Am J Med; 2022 Sep; 135(9):e311-e317. PubMed ID: 35580719
[TBL] [Abstract][Full Text] [Related]
34. Characteristics of Recurrent Ischemic Stroke After Embolic Stroke of Undetermined Source: Secondary Analysis of a Randomized Clinical Trial.
Veltkamp R; Pearce LA; Korompoki E; Sharma M; Kasner SE; Toni D; Ameriso SF; Mundl H; Tatlisumak T; Hankey GJ; Lindgren A; Berkowitz SD; Arauz A; Ozturk S; Muir KW; Chamorro Á; Perera K; Shuaib A; Rudilosso S; Shoamanesh A; Connolly SJ; Hart RG
JAMA Neurol; 2020 Oct; 77(10):1233-1240. PubMed ID: 32628266
[TBL] [Abstract][Full Text] [Related]
35. Advanced interatrial block: A predictor of covert atrial fibrillation in embolic stroke of undetermined source.
Mendieta G; Guasch E; Weir D; Aristizabal D; Escobar-Robledo LA; Llull L; Mont L; Bayés de Luna A; Sitges M
J Electrocardiol; 2020; 58():113-118. PubMed ID: 31816563
[TBL] [Abstract][Full Text] [Related]
36. Post-Stroke Detection of Subclinical Paroxysmal Atrial Fibrillation in Patients With Embolic Stroke of Undetermined Source in the Real World Practice: The Empoli ESUS Atrial Fibrillation (E 2 AF) Study.
Grifoni E; Baldini G; Baldini M; Pinto G; Micheletti I; Madonia EM; Cosentino E; Bartolozzi ML; Bertini E; Dei A; Signorini I; Giannoni S; Del Rosso A; Prisco D; Guidi L; Masotti L
Neurologist; 2023 Jan; 28(1):25-31. PubMed ID: 35486903
[TBL] [Abstract][Full Text] [Related]
37. Effect of Implantable vs Prolonged External Electrocardiographic Monitoring on Atrial Fibrillation Detection in Patients With Ischemic Stroke: The PER DIEM Randomized Clinical Trial.
Buck BH; Hill MD; Quinn FR; Butcher KS; Menon BK; Gulamhusein S; Siddiqui M; Coutts SB; Jeerakathil T; Smith EE; Khan K; Barber PA; Jickling G; Reyes L; Save S; Fairall P; Piquette L; Kamal N; Chew DS; Demchuk AM; Shuaib A; Exner DV
JAMA; 2021 Jun; 325(21):2160-2168. PubMed ID: 34061146
[TBL] [Abstract][Full Text] [Related]
38. Association between Embolic Stroke Patterns, ESUS Etiology, and New Diagnosis of Atrial Fibrillation: A Secondary Data Analysis of the Find-AF Trial.
Maier IL; Schregel K; Karch A; Weber-Krueger M; Mikolajczyk RT; Stahrenberg R; Gröschel K; Bähr M; Knauth M; Psychogios MN; Wachter R; Liman J
Stroke Res Treat; 2017; 2017():1391843. PubMed ID: 28536667
[No Abstract] [Full Text] [Related]
39. Cryptogenic Stroke and Embolic Stroke of Undetermined Source: Risk Factors and Approaches for Detection of Atrial Fibrillation.
Rakhimova I; Semenova Y; Khaibullin T; Kuanysheva A; Kovalchuk V; Abdrakhmanov A
Curr Cardiol Rev; 2022; 18(4):e211221199213. PubMed ID: 34939547
[TBL] [Abstract][Full Text] [Related]
40. Atrial CARdiac Magnetic resonance imaging in patients with embolic stroke of unknown source without documented Atrial Fibrillation (CARM-AF): Study design and clinical protocol.
Kotadia ID; O'Dowling R; Aboagye A; Sim I; O'Hare D; Lemus-Solis JA; Roney CH; Dweck M; Chiribiri A; Plein S; Sztriha L; Scott P; Harrison J; Ramsay D; Birns J; Somerville P; Bhalla A; Niederer S; O'Neill M; Williams SE
Heart Rhythm O2; 2022 Apr; 3(2):196-203. PubMed ID: 35496458
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]