These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 35783680)

  • 1. Air microfluidics-enabled soft robotic transtibial prosthesis socket liner toward dynamic management of residual limb contact pressure and volume fluctuation.
    Lee PS; Gao RZ; Colpitts A; Murdock RW; Dittmer D; Schirm A; Tung JY; Ren CL
    Biomicrofluidics; 2022 May; 16(3):034107. PubMed ID: 35783680
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantifying Bone and Skin Movement in the Residual Limb-Socket Interface of Individuals With Transtibial Limb Loss Using Dynamic Stereo X-Ray: Protocol for a Lower Limb Loss Cadaver and Clinical Study.
    Maikos JT; Chomack JM; Herlihy DV; Paglia DN; Wetterstrand C; O'Connor JP; Hyre MJ; Loan JP; D'Andrea SE
    JMIR Res Protoc; 2024 Apr; 13():e57329. PubMed ID: 38669065
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Modeling the mechanics of elevated vacuum systems in prosthetic sockets.
    Youngblood RT; Hafner BJ; Czerniecki JM; Brzostowski JT; Allyn KJ; Sanders JE
    Med Eng Phys; 2020 Oct; 84():75-83. PubMed ID: 32977925
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A pneumatic reconfigurable socket for transtibial amputees.
    Mollaee S; Fuentes-Aguilar RQ; Huegel JC; Budgett DM; Taberner AJ; Nielsen PMF
    Int J Numer Method Biomed Eng; 2024 Feb; 40(2):e3801. PubMed ID: 38185908
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of prosthetic gel liner thickness on gait biomechanics and pressure distribution within the transtibial socket.
    Boutwell E; Stine R; Hansen A; Tucker K; Gard S
    J Rehabil Res Dev; 2012; 49(2):227-40. PubMed ID: 22773525
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A personalised prosthetic liner with embedded sensor technology: a case study.
    PaternĂ² L; Dhokia V; Menciassi A; Bilzon J; Seminati E
    Biomed Eng Online; 2020 Sep; 19(1):71. PubMed ID: 32928238
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new method to quantify liner deformation within a prosthetic socket for below knee amputees.
    Lenz AL; Johnson KA; Bush TR
    J Biomech; 2018 Jun; 74():213-219. PubMed ID: 29678418
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design and Fabrication of a New Expandable Transtibial Liner with Manual Volume Control: A Prototype.
    M J N; G A; F F; M R
    J Biomed Phys Eng; 2020 Aug; 10(4):543-548. PubMed ID: 32802802
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Progress Toward Optimizing Prosthetic Socket Fit and Suspension Using Elevated Vacuum to Promote Residual Limb Health.
    Wernke MM; Schroeder RM; Haynes ML; Nolt LL; Albury AW; Colvin JM
    Adv Wound Care (New Rochelle); 2017 Jul; 6(7):233-239. PubMed ID: 28736683
    [No Abstract]   [Full Text] [Related]  

  • 10. Predictive prosthetic socket design: part 2-generating person-specific candidate designs using multi-objective genetic algorithms.
    Steer JW; Grudniewski PA; Browne M; Worsley PR; Sobey AJ; Dickinson AS
    Biomech Model Mechanobiol; 2020 Aug; 19(4):1347-1360. PubMed ID: 31741116
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optical fiber Bragg grating-instrumented silicone liner for interface pressure measurement within prosthetic sockets of lower-limb amputees.
    Al-Fakih E; Arifin N; Pirouzi G; Mahamd Adikan FR; Shasmin HN; Abu Osman NA
    J Biomed Opt; 2017 Aug; 22(8):1-8. PubMed ID: 28822140
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Toward improving residual limb climate within prostheses for persons with lower limb loss: a technical note.
    Knight AD; Hendershot BD; Sleeman TJ; Dearth CL; Starker F; Schneider U; Koehler-McNicholas SR; Barrons K; Nickel E; Mion S; Ferguson J; Slater BS; Voss GO; Koester K; Hansen AH
    Prosthet Orthot Int; 2022 Apr; 46(2):202-205. PubMed ID: 34932513
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of Dermo and Seal-In X5 prosthetic liners on pressure distributions and reported satisfaction during ramp ambulation in persons with transtibial limb loss.
    Ali S; Osman NA; Razak A; Hussain S; Wan Abas WA
    Eur J Phys Rehabil Med; 2015 Feb; 51(1):31-7. PubMed ID: 24963603
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical utility of pressure feedback to socket design and fabrication.
    Armitage L; Buller A; Rajan G; Prusty G; Simmons A; Kark L
    Prosthet Orthot Int; 2020 Feb; 44(1):18-26. PubMed ID: 31769736
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantification of Shear Stresses Within a Transtibial Prosthetic Socket.
    Schiff A; Havey R; Carandang G; Wickman A; Angelico J; Patwardhan A; Pinzur M
    Foot Ankle Int; 2014 Aug; 35(8):779-782. PubMed ID: 24850158
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validation of a Custom Interface Pressure Measurement System to Improve Fitting of Transtibial Prosthetic Check Sockets.
    Armitage L; Cho K; Sariyildiz E; Buller A; O'Brien S; Kark L
    Sensors (Basel); 2023 Apr; 23(7):. PubMed ID: 37050838
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Adjustable sockets may improve residual limb fluid volume retention in transtibial prosthesis users.
    Brzostowski JT; Larsen BG; Youngblood RT; Ciol MA; Hafner BJ; Gurrey CJ; McLean JB; Allyn KJ; Sanders JE
    Prosthet Orthot Int; 2019 Jun; 43(3):250-256. PubMed ID: 30628522
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Design of lower limb prosthetic sockets: a review.
    Wang M; Nong Q; Liu Y; Yu H
    Expert Rev Med Devices; 2022 Jan; 19(1):63-73. PubMed ID: 34932435
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An adaptive socket with auto-adjusting air bladders for interfacing transhumeral prosthesis: A pilot study.
    Gu Y; Yang D; Osborn L; Candrea D; Liu H; Thakor N
    Proc Inst Mech Eng H; 2019 Aug; 233(8):812-822. PubMed ID: 31165676
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Generic, geometric finite element analysis of the transtibial residual limb and prosthetic socket.
    Silver-Thorn MB; Childress DS
    J Rehabil Res Dev; 1997 Apr; 34(2):171-86. PubMed ID: 9108344
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.